3Com 3646A, 3644A, 3645A manual Power Definition Interface, Parameter Explanation

Page 21

3600 SERIES USER MANUAL

Chapter 4 The introduction of main functions

4.1 The Definition of the Power Supply

Select the function item and then the interface as shown in Fig. 4-1 will be displayed.

Fig 4-1 The Power Definition Interface

Add: Select “Add” in the function items and input the contents of each item. After the set of the input, select “Save” to save it.

Delete: Select the POWER record to be deleted in the table and then select “Delete”. Finally select “Save” and it will be OK.

Modify: Select the POWER record to be modified in the table and then select “Modify” to modify it. After the modification, select “Save” and it will be OK.

Query: Select “Query” and then wait for the name of the power supply to be queried.

Show: Select “Show” and it will show all the records.

Print: Select “Print” and it will print all the current records.

Parameter Explanation

Parametrer

Explanation

Range

Remarks

Power Name

Name Of the Power Supply

Must be Input

 

Current Up

The Max Current

0~5A/ 0~3A0~1.5A

Must be Input

 

 

 

 

Power Up

The Max Power

0~90W/0~108W/0~108W

Must be Input

 

 

 

 

Voltage Configure

The Max Voltage

0~18V/0~36V/0~72V

Must be Input

 

 

 

 

Configure

 

 

 

ID

The ID Number

 

No Consideration

 

 

 

 

Notes: When selecting the “Add” function item to add POWER, the name and address of the POWER cannot be repeated. After selecting the inputs, click “OK” and the dialogue frame as shown in Fig. 4-2 will be displayed. In Fig.4-3, select “YES” and the system will close and restart.

3600 Series Programmable Power Supply

VERSION 2.0 2004.6

19

 

Image 21
Contents Page Series Series Programmable Power Supply Version 2.0 II. Connecting the power line SafetyIII.Fuse IV. Power supplyPowermax Specification ModelProgram resolution Readback resolutionDimensions WeightFeatures ProtectionLCD Display of 3600 Series Powersupply Front view of 3600 Series DC power supplyStructure Front view Rotary knob and function keys Back view General operation Sub-functionsOperation of the function To set up by using Rotary knob Set up voltageEnable/disable the output Set up currentSave Store parametersFunction of the Menu Recall parametersSet up the maximum output power Set up the maximum output voltageSet up initial output state Enable/disable the rotary knobSave voltage setting Set up the communication speedLock the keypad Set up communication address 0~31Clear saved parameters ExitSystem Installation Installation Initial InterfaceInstallation Interface System Start Interface Installation Interface System StartSystem Start Diagram 10 The PowerMS Main Interface ExplanationSystem Uninstallation Parameter Explanation Power Definition InterfacePower Address Set COM Port and address setCOM Port Failure Opening frame Communication Failure Selecting the PowerStart the Communication Normal Communication11 Using the Rotary knobFig 4-12 Using the Keypad Select PC to Power Control Instructions10-1 Select the Control Instruction 10-2 Selecting Control Instruction Set the Voltage RangeQuery the Report 15 Query the Report16 Delete the History Data 18 Keypad Explanation State Bar Current Running Diagram Voltage Running DiagramExplanation of the Interface Indicating Components 17 Instrument IndicationExit the System Power Supply State Indication