3Com 3645A, 3646A, 3644A manual Communication Failure, Start the Communication, Normal Communication

Page 23

3600 SERIES USER MANUAL

In Fig. 4-5, enter the default address (245) of the power supply and then click “READ”. If testing successfully, the “NEW ADDRESS” and “WRITE” functions will be available. If testing failure, then the new address of the power cannot be set and the prompting diagram as shown in Fig. 4-6 will be displayed. This time the communication cable must be checked.

Fig 4-6 Communication Failure

Explanation: For the first installation each POWER must be deployed with but one address in order to communicate correctly. Set the parameter and select “OK” and it will enter into the common communication. The default COM port is COM1 and the default POWER address is 0.

4.3 Start the Communication

After the COM port and ADDRESS set, select the button and the system will start the communication. If the communication is normal, the prompt information as shown in Fig. 4-7 will be displayed. And if the commu- nication is failure, the prompt information as shown in Fig. 4-8 will be displayed.

Fig 4-7 Normal Communication

Fig 4-8 Failure Communication

4.4 Stop the Communication

 

 

Select the button

and the system will stop the communication.

4.5 Select POWER

In Fig. 4-9 , select the POWER name from the listing frame and it will be OK.

Fig 4-9 Selecting the POWER

3600 Series Programmable Power Supply

VERSION 2.0 2004.6

21

 

Image 23
Contents Page Series Series Programmable Power Supply Version 2.0 II. Connecting the power line SafetyIII.Fuse IV. Power supplyReadback resolution Specification ModelPowermax Program resolutionProtection WeightDimensions FeaturesStructure Front view LCD Display of 3600 Series PowersupplyFront view of 3600 Series DC power supply Rotary knob and function keys Back view Operation of the function General operationSub-functions To set up by using Rotary knob Set up voltageEnable/disable the output Set up currentSave Store parametersFunction of the Menu Recall parametersSet up the maximum output power Set up the maximum output voltageSet up the communication speed Enable/disable the rotary knobSet up initial output state Save voltage settingExit Set up communication address 0~31Lock the keypad Clear saved parametersInstallation Interface System InstallationInstallation Initial Interface System Start Interface Installation Interface System StartSystem Uninstallation System Start Diagram10 The PowerMS Main Interface Explanation Parameter Explanation Power Definition InterfaceCOM Port Failure Opening frame Power Address SetCOM Port and address set Normal Communication Selecting the PowerCommunication Failure Start the Communication10-2 Selecting Control Instruction Set the Voltage Range Select PC to Power Control Instructions11 Using the Rotary knobFig 4-12 Using the Keypad 10-1 Select the Control Instruction16 Delete the History Data Query the Report15 Query the Report 17 Instrument Indication Voltage Running Diagram18 Keypad Explanation State Bar Current Running Diagram Explanation of the Interface Indicating ComponentsExit the System Power Supply State Indication