Chapter 4 | Designing Labels Using LDS |
))))))))))))))))))))))))))))))))))))))))))))
4.3LABEL HEADER
The header is broken down into eleven different parameters. These parameters contain information about the label. It is not necessary to enter information for all of the parameters: If a parameter is left blank, then the default value will be used. A carriage return must follow the label header.
The value of measurement for many of the header elements is the dot. There are 154 dots per inch across the print head (6 dots/mm). There is a maximum 640 dots in the X direction (width). Y direction (length) is virtually unlimited.
Most of the header parameters can be supplied by
Below is a list of the header element mnemonics and their default values:
HFM, LSX, LSY, WEB, GAP, DPS, LCB, AGD, SPG, OFX, OFY 0, 640, 443, 10, 10, 35, 0, 1, 352, 0, 0
Label Header Parameters of a 4" X 3" Label
Figure 6
))))))))))))))))))))))))))))))))))))))))))))
410 Operators Manual | 21 |