FENIX IMVICO | TK14 OPERATION MANUAL |
For these reasons, FENIX suggests the following systems as solutions to a correct installation:
The printer must be set quite near the front side of the user’s chassis.
Special care in the design of the part which goes from the printer outlet to the paper guide (paper jams can occur due to an inappropriate design).
As the printer is placed very near the user’s chassis, some system must be implemented in order to move the printer when accessing the printing head (i.e. giving the fixing holes of the chassis an oval shape to allow the printer moving forward and backward).
MINIMAL NOZZLE
HOLE DIMENSION IN
THE USER FRONT
PANEL
Fig. 2.2- Nozzle hole dimension.
Depending on the construction materials, care must be taken with static electricity; otherwise tickets may get stuck in the paper guide and never reach the receptacle.
Be sure to make a good earth connection, performing one of the following schemes:
Power supply
earth
Tk14
C0N1
shorted
J1 Chassis
a)The earth connection is at the power supply and shorted with the negative terminal.
The chassis is connected to earth shorting the jumper J1.
Power supply
Tk14 | b)The negative terminal is |
| |
floating. |
| ||
|
| ||
| The chassis is connected to |
| |
C0N1 | earth by a cable from the | M3 Screw + Grower | |
NOT shorted | main earth connection. | ||
| |||
J1 |
|
| |
Chassis | Fig. 2.3- TK14 earth connection. |
12/65