Toshiba DEV002Z instruction manual E6581295⑥ Data composition of output instance, Off

Page 17

E6581295

Data composition of output instance 100

Byte

bit

0

0

0

1

0

2

0

3

0

4

0

5

0

6

0

7

 

 

1

0

1

1

1

2

1

3

 

 

1

4

1

5

1

6

1

7

 

 

Specifications

0

1

 

Supplement

 

 

Preset speed #1*1

 

 

A combination of 4 different bits is used

Preset speed #2*1

Preset speed OFF: 0000,

to select a preset speed from among

Preset speed #3*1

Preset speed #1-#15: 0001 to 1111

preset speed operation OFF and preset

Preset speed #4*1

 

 

speed #1 to #15.

 

 

 

 

 

 

Used

to

select

a

motor

Motor #1/#2

Motor #1

Motor #2

electronic-thermal protection level.

 

(THR2 selection)

(THR1)

(THR2)

0: Protection level #1 (thr)

 

 

 

 

1: Protection level #2 (f173)

 

PI control

Normal operation

PI control off

 

 

-

 

 

Acceleration/

Acceleration/

Acceleration/

Used to select acceleration/deceleration

Deceleration

time.

 

 

 

 

Deceleration #1

Deceleration #2

 

 

 

 

#1/#2 selection

0: acc, dec

 

 

 

(AD1)

(AD2)

 

 

 

(AD2 selection)

1: f500, f501

 

 

 

 

 

 

DC braking

OFF

Forced DC

If “1” is specified, db is displayed.

 

braking

 

 

 

 

 

 

 

 

JOG run*2

 

 

If “1” is specified, operation is performed

OFF

JOG run

at the frequency specified with f260

 

 

 

(jog run frequency).

 

 

Forward run/

Forward run

Reverse run

 

 

-

 

 

Reverse run

 

 

 

 

 

 

 

 

 

 

 

Run/Stop

Stop

Run

 

 

-

 

 

Coast stop

Ready for

Coasting

 

 

-

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

Emergency stop

OFF

Emergency stop

If “1” is specified, e tripping can occur.

Reset

OFF

Reset

Enabled only in the event of tripping

Frequency link

OFF

Priority

Enabled regardless of the setting

 

of fmod

 

 

 

 

 

 

 

 

 

Command link

OFF

Priority

Enabled regardless of the setting

 

of cmod

 

 

 

 

 

 

 

 

 

*1: Preset speed operation can be performed at up to 15 different frequencies (preset speed operation frequencies #1 to #15) specified by combining preset speed 1 to preset speed 4. To perform preset speed operation, the “Command priority” option and the “Run/Stop” bit must be set to 1.

Example: To run the motor in the reverse direction at preset speed operation frequency #7 (sr7)

“10000110 00000111= 0x8607 (hexadecimal)

If one of the bits for “Preset speed #1” to “Preset speed #4” is set to 1, priority is given to preset speed operation even though the “Frequency link” bit is set to 1, and therefore operation is not performed by “Frequency link”.

*2: Jog operation has higher priority than preset speed operation. If the operation frequency is higher than the jog run frequency, however, jog operation is not carried out.

- 16 -

Image 17
Contents Tosvert VF-AS1/PS1 Safety precautions Page Page Introduction Contents VF-AS1/PS1 OverviewDEV002Z VF-AS1/PS1 DEV002ZDeviceNet connector Exterior featuresCanh CanlLED DeviceNet indicatorInstalling the DEV002Z Installation method Connecting to the networkNetwork Grounding MAC ID Setting a MAC ID number and a network baud rateCommunications-related parameters F852 Preset speed operation selection F851 Communication Loss Action Setting Network breaksAlarm F830 Assembly Object SettingReady ST/RUN ST/ RUNOFF E6581295⑥ Data composition of output instanceST=ON ST=ON ST=OFFVF-AS1/PS1 RR/S4 CCA SW1 Source Sink DeviceNet Local/Remote OperationWarranty Specifications