Toshiba DEV002Z DeviceNet Local/Remote Operation, VF-AS1/PS1 RR/S4 CCA SW1 Source Sink

Page 19

E6581295

6. DeviceNet Local/Remote Operation

The example below shows how to configure the VF-AS1/PS1 for local / remote operation.

<Terminal function>

 

F terminal

Operating command

R terminal

DeviceNet/Local (Terminal in this example) switching

RR/S4 terminal....

Operation frequency command

<Wiring>

 

Variable resistor for adjustment 1 - 10k ohm

Operation command

DeviceNet/Local

Switch

VF-AS1/PS1

 

PP

 

 

RR/S4

 

CCA

SW1

 

F

 

 

R

SOURCE

SINK

 

 

CC

 

 

<Parameter setting>

cmod (Command mode selection) = 0 (Terminal board) fmod (Frequency setting mode selection 1) = 2 (RR/S4)

f112 (Input terminal selection 2 (R)) = 48 (Remote/Local control)

<Operation>

R-CC terminal open:

VF-AS1/PS1 is controlled as slave device of DeviceNet. R-CC terminal closed:

F-CC terminal short to RUN F-CC terminal open to STOP

Output frequency is set up by the RR/S4 signal input.

- 18 -

Image 19
Contents Tosvert VF-AS1/PS1 Safety precautions Page Page Introduction Contents VF-AS1/PS1 DEV002Z OverviewVF-AS1/PS1 DEV002ZCanl Exterior featuresDeviceNet connector CanhLED DeviceNet indicatorInstalling the DEV002Z Installation method Connecting to the networkNetwork Grounding MAC ID Setting a MAC ID number and a network baud rateCommunications-related parameters F852 Preset speed operation selection F851 Communication Loss Action Setting Network breaksST/RUN ST/ RUN F830 Assembly Object SettingAlarm ReadyOFF E6581295⑥ Data composition of output instanceST=ON ST=ON ST=OFFVF-AS1/PS1 RR/S4 CCA SW1 Source Sink DeviceNet Local/Remote OperationWarranty Specifications