Diagnostics over Industrial Ethernet
●IP address
IP address of the ELS (maximum range per field: 0 to 255). If you enter an invalid IP address, a warning is displayed and the input is rejected.
●Subnet mask
Subnet mask of the ELS (maximum range of numbers per field: 0 to 255).
●Router (default gateway)
Enter the IP address of the default gateway if the PC/Internet Browser is not in the same subnet as the ELS.
Note
Changing the parameters resets and restarts the ELS. This can take up to 15 seconds.
3.Close the folder by clicking on the icon in the menu tree again and download your configuration to the ELS
by selecting Module -> Download.
A progress bar indicates the status of the download.
You can also start this action directly using the appropriate icons in the toolbar (see Figure
Figure 6-8 Direct Start: "Download Module"