Toshiba 120/150 manual Connecting the Interface Cable, Interface cable, Parallel interface cable

Page 80

CONNECTING THE INTERFACE CABLE

This unit includes both USB and parallel interface connectors.

Interface cables for connecting the unit to your computer are not included with this unit. Please purchase the appropriate cable for your computer.

Interface cable

Parallel interface cable

IEEE 1284-Shielded type bi-directional parallel interface cable (2 m (6 feet) Max.)

USB interface cable

Shielded twisted pair cable, high-speed transmission equivalent (2 m (6 feet) Max.)

If you intend to use the unit as a scanner, it must be connected to your computer with a

USB interface cable. The scanner function cannot be used if the unit is connected with a parallel cable.

USB is available with a PC/AT compatible computer that was originally equipped with USB and had Windows 98, Windows Me, Windows 2000 Professional, Windows XP Professional or Windows XP Home Edition preinstalled.

Do not connect the interface cable before installing the MFP driver. The interface cable should be connected during installation of the MFP driver. (See “INSTALLING THE SOFTWARE” p. 7-5)

Connecting the USB interface cable

1 Obtain a shielded USB interface cable.

2 Insert the cable into the USB interface connector located on the rear of the unit.

3 Insert the other end of the cable into the interface connector of your computer, or the USB hub connected to your computer.

7-29

Image 80
Contents Networking Documents %## FCC regulations User safety Ozone informationMachine noise information For user in the CanadaVaroitus Page Important points when selecting an installation site Do not install your unit in areas that areProper storage for supplies Trademark acknowledgementsDo not touch the photoconductive drum green portion Store paper in the wrapper and lying flatContents Appendix Page This chapter provides basic information for using the unit IntroductionUsing the Manual Conventions used in this manualPart Names Photoconductive drum Toner cartridgeOperation Panel Loading Paper Type of paper feeding Type of media Size Weight PaperTransparency FilmProper storage Loading the Paper Tray Gently push the paper tray back into the unit Bypass Feed including special paper Open the bypass tray and extend the trayPrint face 8LOADING Paper Making Copies Copy Flow Connecting the Power Cord Power onAbout the scan head Initial settings of operation panelPower off methods Original Placement Setting a large originalSET the Copy Quantity Exposure ADJUSTMENT/PHOTO CopyingExposure adjustment Automatic exposure adjustment To select a preset copy ratio REDUCTION/ENLARGEMENT/ZOOMTo select a zoom ratio RatioSelecting the Tray Press the tray select Key10MAKING Copies Special Functions Toner Save Mode Description of Special FunctionsUser Programs Copies will appear in two steps, each with three digits Program Mode ParametersDisplaying Total Number of Copies Maintenance Toner Cartridge Replacement Or 5 times Shutter Toner seal 4MAINTENANCE Original table and the back side of the original cover Cleaning the UnitCabinet Transfer charger Troubleshooting the Unit Troubleshooting Problem Possible cause SolutionStatus Indicators Be sure to use only genuine Toshiba parts and suppliesMisfeed Removal Misfeed in the paper feed area Misfeed in the fusing areaLower the fusing unit release lever Start indicator will light up Misfeed in the transport areaDeveloper Required Maintenance RequiredWill go out and the start indicator will light up 8TROUBLESHOOTING Installing the Software Software for the Toshiba Personal MFP Series MFP driverDesktop Document Manager Button ManagerBefore Installation Hardware and Software RequirementsFlow of installation Operatingsystem Interface Reference pages for how to installDouble-click the setup icon Installing the SoftwareInstalling onto Windows XP USB/parallel interface Install the Software Page Begin installation of the scanner driver 12Begin installation of the printer driverInstalling onto Windows 98/Me/2000 USB interface Copying files for MFP driver installation 10Connect the USB interface cable. See p Windows 95/NT Windows 98/Me/2000 Page Page Indicators on the Operation Panel Start indicatorPower save indicator Online indicatorUsing the Printer Mode How to printOpening the printer driver from the start menu Click the start buttonConfiguring the Option About interrupt copyingUsing the Scanner Mode Using the Button ManagerSetting up the Button Manager Windows XPWindows 98/Me/2000 Scan Parameter Setting Dialog Box Flow of the Button Manager settingScanner e Event Using the Scanner key to begin scanning Press the Scanner keyUsing the Toshiba Twain Opening the scanner driver and scanning from your computerPress the start key Place the original you wish to scan on the original tableScan is started Click Finish in the screen that appears Scanning with the Scanner and Camera Wizard in Windows XPSelect a name, format, and folder for the scanned image HOW to USE the Online Manual Contents of the online manualClick theto read the online manual Using Other Installed Drivers Connecting the Interface Cable Connecting the USB interface cableInterface cable Parallel interface cableConnecting the parallel interface cable Appendix Specifications Model STUDIO120 DP-1210 STUDIO150 DP-1510Software Sheet paper feed unit MY-1019System configuration Optional EquipmentAuto document feeder MR-2014 Part namesUsing the ADF SpecificationsStream feeding mode Misfeed in the ADFPart names Loading copy paper Side cover TrayMisfeed removal Alarm indicator Developer replacement required IndexScanning with the Scanner Software License Disclaimer of Warranty on Software Toshiba Tec Germany Imaging Systems GmbH