Toshiba 120/150 User safety, Ozone information, Machine noise information, For user in the Canada

Page 4

User safety

This Toshiba digital plain paper copier does not produce laser radiation hazardous to the user. It is certified as a Class 1 laser product under the U.S.Department of Health and Human Services (DHHS) Radiation Performance Standard according to the Radiation Control Health and Safety Act of 1968.

Protective housing and external covers completely confine the laser light emitted inside the plain paper copier. The laser beam cannot escape from the machine during any phase of user operation.

Regulations implemented on August 2, 1976 by the Bureau of Radiological Health (BRH) of the U.S.Food and Drug Administration apply to laser products manufactured from August 1, 1976. Laser products marketed in the United States must comply with these regulations.

CAUTION : Using controls or adjustments or performing procedures, other than those specified herein may result in hazardous radiation exposure.

Ozone information

After a suitable place has been selected for the installation, please do not change it. Avoid excessive heat dust vibration and direct sunlight. Also, provide proper ventilation as the copier emits a small amount of ozone.

A small amount of ozone is produced within the unit during operation. The emission level is insufficient to cause any health hazard.

Note:

The present recommended long term exposure limit for ozone is 0.1ppm (0.2mg/m3) calculated as an 8hr. time-weighted average concentration.

However, since the small amount that is emitted may have an objectionable odor, it is advisable to place the unit in a ventilated area.

Machine noise information

Ordinance 3. GSGV, January 18, 1991: The maximum sound pressure level is equal or less than 70 dB(A) according to EN27779.

For user in the Canada

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.

For user in the Europe

1.Do not touch the connector terminal when disconnecting the cables of peripheral equipment.

2.Before opening any covers or removing any units from the copier, discharge the static electricity from your body by touching a metal part of the copier.

This product is carrying the CE-Mark in accordance with the related European Directives. Responsible for CE-marking is TOSHIBA TEC GERMANY IMAGING SYSTEMS GmbH, Carl-Schurz-Str.7, 41460 Neuss, Germany.

e-mail : customerservice@toshibatec-tgis.com.

3

Image 4
Contents Networking Documents %## FCC regulations User safety Ozone informationMachine noise information For user in the CanadaVaroitus Page Important points when selecting an installation site Do not install your unit in areas that areProper storage for supplies Trademark acknowledgementsDo not touch the photoconductive drum green portion Store paper in the wrapper and lying flatContents Appendix Page This chapter provides basic information for using the unit IntroductionUsing the Manual Conventions used in this manualPart Names Photoconductive drum Toner cartridgeOperation Panel Loading Paper Type of paper feeding Type of media Size Weight PaperTransparency FilmProper storage Loading the Paper Tray Gently push the paper tray back into the unit Bypass Feed including special paper Open the bypass tray and extend the trayPrint face 8LOADING Paper Making Copies Copy Flow Connecting the Power Cord Power onPower off methods Initial settings of operation panelAbout the scan head Original Placement Setting a large originalExposure adjustment Exposure ADJUSTMENT/PHOTO CopyingSET the Copy Quantity Automatic exposure adjustment To select a preset copy ratio REDUCTION/ENLARGEMENT/ZOOMTo select a zoom ratio RatioSelecting the Tray Press the tray select Key10MAKING Copies Special Functions Toner Save Mode Description of Special FunctionsUser Programs Displaying Total Number of Copies Program Mode ParametersCopies will appear in two steps, each with three digits Maintenance Toner Cartridge Replacement Or 5 times Shutter Toner seal 4MAINTENANCE Cabinet Cleaning the UnitOriginal table and the back side of the original cover Transfer charger Troubleshooting the Unit Troubleshooting Problem Possible cause SolutionStatus Indicators Be sure to use only genuine Toshiba parts and suppliesMisfeed Removal Lower the fusing unit release lever Misfeed in the fusing areaMisfeed in the paper feed area Start indicator will light up Misfeed in the transport areaWill go out and the start indicator will light up Maintenance RequiredDeveloper Required 8TROUBLESHOOTING Installing the Software Software for the Toshiba Personal MFP Series MFP driverDesktop Document Manager Button ManagerBefore Installation Hardware and Software RequirementsFlow of installation Operatingsystem Interface Reference pages for how to installInstalling onto Windows XP USB/parallel interface Installing the SoftwareDouble-click the setup icon Install the Software Page Begin installation of the scanner driver 12Begin installation of the printer driverInstalling onto Windows 98/Me/2000 USB interface Copying files for MFP driver installation 10Connect the USB interface cable. See p Windows 95/NT Windows 98/Me/2000 Page Page Indicators on the Operation Panel Start indicatorPower save indicator Online indicatorUsing the Printer Mode How to printOpening the printer driver from the start menu Click the start buttonConfiguring the Option About interrupt copyingUsing the Scanner Mode Using the Button ManagerSetting up the Button Manager Windows XPWindows 98/Me/2000 Scan Parameter Setting Dialog Box Flow of the Button Manager settingScanner e Event Using the Scanner key to begin scanning Press the Scanner keyUsing the Toshiba Twain Opening the scanner driver and scanning from your computerPress the start key Place the original you wish to scan on the original tableScan is started Select a name, format, and folder for the scanned image Scanning with the Scanner and Camera Wizard in Windows XPClick Finish in the screen that appears HOW to USE the Online Manual Contents of the online manualClick theto read the online manual Using Other Installed Drivers Connecting the Interface Cable Connecting the USB interface cableInterface cable Parallel interface cableConnecting the parallel interface cable Appendix Specifications Model STUDIO120 DP-1210 STUDIO150 DP-1510Software Sheet paper feed unit MY-1019System configuration Optional EquipmentAuto document feeder MR-2014 Part namesUsing the ADF SpecificationsStream feeding mode Misfeed in the ADFPart names Loading copy paper Side cover TrayMisfeed removal Alarm indicator Developer replacement required IndexScanning with the Scanner Software License Disclaimer of Warranty on Software Toshiba Tec Germany Imaging Systems GmbH