Adder Technology CATxIP 1000 Multiple video head connections, USB-type and that it is plugged

Page 18

Multiple video head connections

Two or more AdderView CATxIP 1000 units can be connected together so that they operate in a synchronised manner. Synchronised operation is useful for applications that require multiple video signals to be switched together. This type of operation is usually required where each computer is fitted with multiple video cards or video cards with multiple video heads. Whenever an AdderView CATxIP 1000 channel is switched, it sends an RS232 command out on its serial interface (marked OPTIONS on the rear panel). An AdderView CATxIP 1000 will switch its channel if it receives the same command on its serial interface. Consequently, by linking the serial interfaces, a master unit may be made to automatically switch one or more slave units as shown in the diagram.

LOCAL LOCAL

USER USER

CAM CAM

HOST

COMPUTER

Serial synchronisation cable

Slave AdderView CATxIP 1000

 

16

15

14

13

8

7

6

5

ONLY

 

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOORUSE

5V

12

11

10

9

4

3

2

1

2.0A

 

 

 

COMPUTER CONNECTIONS

 

 

COMPUTER CONNECTIONS

 

 



Note: You must ensure that all AdderView CATxIP 1000 units have their Options serial ports set to ‘Sync Units’ and that their baud rates are identical. These settings can be made either via the local or global user configuration menus.

It should be noted that the synchronisation cable deliberately does not have the transmit pin of the Slave End connector linked to the receive pin of the Master End connector. To do so would cause the Slave unit to be able to switch the Master unit. This would setup an endless cyclical switching sequence that would prevent the AdderView CATxIP 1000 devices from operating correctly. For more details about the serial synchronisation cables, see Appendix 7.

 

16

15

14

13

8

7

6

5

ONLY

 

OPTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOORUSE

5V

12

11

10

9

4

3

2

1

2.0A

 

 

 

COMPUTER CONNECTIONS

 

 

COMPUTER CONNECTIONS

 

 

Master AdderView CATxIP 1000

 

Notes

Slave monitor

Master monitor

It is recommended that the

 

 

 

 

 

 

 

 

second CAM in each pair is a

CAM CAM

CAM CAM

 

 

USB-type and that it is plugged

 

 

 

 

 

 

to a vacant USB port on the host

 

 

 

 

computer to derive its power.

 

 

Pairs of CAMs can be strapped back-to-back with cable ties to create a tidy installation.

Computers fitted with dual video heads

 



17

Image 18
Contents AdderView CATxIP Contents Further information Index Global users Many computersCAM formats AdderView CATxIP 1000 features front and rear What’s in the box What you may additionally needMounting Single unit rack bracketsDouble unit rack brackets CAM Computer Power System Switch ConnectionsLocal user To connect the local user portAdderView CATxIP Front panel Global user IP network portTo connect the Global user IP network port Category 5, 5e or 6 cable from Adder X100/X200 moduleComputer system via CAM To connect a computer systemPower in connection To connect the power supplyOutput lead from Power adapter Power control port To connect and address the switch boxesSwitch Cascading multiple units See alsoCascade tree Connecting units in cascade Tips for successful cascadingTo connect units in cascade Using cascaded computers Addressing computers in a cascadeMultiple video head connections It is recommended that Second CAM in each pair is aUSB-type and that it is plugged Remote switching control Host computer port/channel Video offCable from serial Control device Configuration Overall initial configurationInitial configuration Hotkeys Main menuMenu layout SecurityTo set an Admin password General security and configuration stepsTo enable general security Registering users and host computersWhat to do if the Admin password has been forgotten To clear a password and restore factory default settingsClearing IP access control What is IP access control?To clear IP access control Full configuration by global user To configure the unit from a global user locationEncryption settings AdderView CATxIP 1000 encryption settingsViewer encryption settings Networking issues Positioning AdderView CATxIP 1000 in the networkAddressing Port settingsPlacing AdderView CATxIP 1000 behind a router or firewall Firewall/router addressTo discover a DHCP-allocated IP address DNS addressingPlacing AdderView CATxIP 1000 alongside the firewall Ensuring sufficient securityPorts To configure the power sequences for each host computer Power switching configurationPower control sequences To control two or more ports simultaneouslyTo invoke backup/recovery mode Recovering from a failed upgradeTo upgrade AdderView CATxIP 1000 models Upgrading AdderView CATxIP 1000 modelsAccessing the AdderView CATxIP Front panel indicatorsLocal user access Selecting a computerTo select a computer using the Select Host menu Standard hotkeysSelect Host menu here you can select computers by name Logging in and out To select a computer using mouse buttonsTo select a computer using mouse buttons Advanced method To logConfirmation box To enable/disable the confirmation boxTo change banner colours or disable the banner Reminder bannerBlue dot indicators in the Select Host menu User preferences and functionsGlobal user access Global UserTo download the VNC viewer Global user access via VNC viewerTo access via the VNC viewer Options buttonGlobal user access via web browser To access via your web browserUsing the viewer window When using the viewer windowMenu bar Host selection ConfigureMouse pointers To select a hostAuto calibrate Access mode shared/privatePower switching Re-synchronise mouseControls Keyboard Control When entering codesVideo Settings EnterSetting the Threshold manually Using automatic configurationsIncreased by 50% when a slow link is detected AccordinglyAdvanced Settings Custom Video ModesOverlap Capture Viewer encryption settings If you need to enter a port numberSupported web browsers Getting assistance TroubleshootingWhen logging on using VNC viewer, I cannot enter a username US +1 888 275Appendix 1 Local setup menus To access the local setup menusRestore Intellimouse Power ControlRestore Standard Mouse FunctionsReminder Colour User PreferencesReminder Banner Screen SaverGlobal Preferences Mouse SwitchingUser Timeout OSD Dwell TimeSetup Options Auto LogoutCompletely resets the AdderView CATxIP 1000 unit ConfigurationIP admin password, encryption settings, etc IP address, net mask, VNC port, etcUnit Configuration Network Configuration Settings 1200, 2400, 4800, 9600, 19200, 38400, 57600 Serial ConfigurationSettings Power Control, Sync Units Options PortReset Configuration To reset the AdderView CATxIP 1000 configurationAppendix 2 Configuration pages via viewer To access the remote configuration pagesMain configuration Logged on users User accounts Unit configuration Advanced unit configuration Time & date configuration IP Network Mask Network configurationIP Access Control IP GatewayTo reorder access control entries Setting IP access controlTo define a new IP access control entry To edit/remove access control entriesSerial port configuration Options Port UseBaud Rate Add entry for unrecognised host Host configurationErase Host Configuration To create a new host entrySyslog Server IP Address Logging and statusTo copy and paste the log For further details To get hereLdap configuration Auto select Appendix 3 VNC viewer connection optionsColour/Encoding Preferred encodingInputs Enable all inputsDisable all inputs view-only mode CustomiseMisc Scale to Window Size ScalingNo Scaling Custom SizeIdentities Defaults ReloadDefaults Save Load / SaveAppendix 4 VNC viewer window options Appendix 5 Browser viewer options Encoding and colour levelSecurity Appendix 6 Addresses, masks and ports IP addressesNet masks Binary equivalent Net masks the binary explanationOperation with net mask Binary octet afterAll locations Calculating the mask for IP access controlSingle locations Address rangesSecurity issues with ports PortsAppendix 7 Cable and connector specifications AdderView CATxIP 1000 to power switch cablePower switch to power switch daisy chain cable Appendix 8 Hotkey sequence codes Permissible key pressesCreating macro sequences Appendix 9 Supported video modes Warranty Safety informationGeneral Public License Linux End user licence agreement FCC Compliance Statement United States Radio Frequency EnergyEuropean EMC directive 89/336/EEC Canadian Department of Communications RFI statementHoe Huat Industrial Building Index 