Advanced unit configuration

Click this button to display advanced options that do not normally require alteration.

To get here

1Using VNC viewer or a browser, log on as the ‘admin’ user.

2Click the ‘Configure’ button in the top right corner.

3Click the ‘Unit Configuration’ option.

4Click the ‘Advanced Unit Configuration’ option.

Force VNC Protocol 3.3

IMPORTANT: The use of this option is not recommended. Protocol 3.3 is a legacy version that does not offer any encryption.

Idle Timeout

Determines the period of inactivity on a global connection before the user is logged out. The idle timeout period can be set to any time span, expressed in minutes. Note: The Screensaver option serves a similar purpose for local connections.

Protocol Timeout

Sets the time period by which responses should have been received to outgoing data packets. If the stated period is exceeded, then a connection is considered lost and terminated.

Mouse Latency Allowance

This option is used during calibration to account for latency delays (caused as signals pass through a device) introduced by some KVM switches from alternative manufacturers.

During calibration, the AdderView CATxIP 1000 waits for 40ms after each mouse movement before sampling the next. If a KVM device adds a significant delay to the flow of data, the calibration process can be lengthened or may fail entirely. The value entered here is added to (or subtracted from) the default 40ms sampling time.

Note: You can enter negative values (down to -40) in order to speed up the calibration process when using fast KVM switches. Use this option with caution as it can adversely affect the calibration process.

Mouse Rate

Defines the rate at which mouse movement data are transmitted to the system. The default option is 20ms, which equates to 50 mouse events per second. This default rate can prove too fast when passed through certain connected KVM switches from alternative manufacturers. In such cases, data are discarded causing the local and remote mouse pointers to drift apart. If this effect is encountered, increase the mouse rate to around 30ms (data are then sent at a slower rate of 33 times per second).

Background Refresh Rate

Use the arrow keys to alter the refresh rate for screen images via remote links. This allows you to tailor the screen refresh to suit the network or modem connection speeds. The options are: Slow, Medium, Fast or Disabled. When the disabled option is selected, the remote users will need to manually refresh the screen.

Note: When a low connection speed is detected, the background refresh is automatically disabled, regardless of the settings of this option.

Single Mouse Mode Mouse Switch

Allows you to select the mouse button combination that can be used to exit from single mouse mode (when active).

Behaviour for admin connections when limit reached

Determines what should occur when four global connections already exist and a fifth, administrator connection attempt is made. Options are: Replace oldest connection, Replace newest connection and Don’t replace. Only non-administrator connections can be terminated in this way.

Use VESA GTF

When ticked, the VESA Generalized Timing Formula will be used to help determine the correct input video resolution and timing details. See Appendix 9 for a list of all supported video modes.

Upgrade firmware

Places the unit into upgrade mode. See Upgrading AdderView CATxIP 1000 models.

   



64

Image 65
Contents AdderView CATxIP Contents Further information Index CAM formats Global usersMany computers AdderView CATxIP 1000 features front and rear What you may additionally need What’s in the boxDouble unit rack brackets MountingSingle unit rack brackets Connections CAM Computer Power System SwitchTo connect the local user port Local userTo connect the Global user IP network port Global user IP network portAdderView CATxIP Front panel Category 5, 5e or 6 cable from Adder X100/X200 moduleTo connect a computer system Computer system via CAMOutput lead from Power adapter Power in connectionTo connect the power supply Switch Power control portTo connect and address the switch boxes Cascade tree Cascading multiple unitsSee also To connect units in cascade Connecting units in cascadeTips for successful cascading Addressing computers in a cascade Using cascaded computersUSB-type and that it is plugged Multiple video head connectionsIt is recommended that Second CAM in each pair is a Cable from serial Control device Remote switching controlHost computer port/channel Video off Overall initial configuration ConfigurationInitial configuration Menu layout Main menuHotkeys SecurityTo enable general security General security and configuration stepsTo set an Admin password Registering users and host computersTo clear a password and restore factory default settings What to do if the Admin password has been forgottenTo clear IP access control Clearing IP access controlWhat is IP access control? To configure the unit from a global user location Full configuration by global userViewer encryption settings Encryption settingsAdderView CATxIP 1000 encryption settings Positioning AdderView CATxIP 1000 in the network Networking issuesPlacing AdderView CATxIP 1000 behind a router or firewall Port settingsAddressing Firewall/router addressDNS addressing To discover a DHCP-allocated IP addressPorts Placing AdderView CATxIP 1000 alongside the firewallEnsuring sufficient security Power control sequences Power switching configurationTo configure the power sequences for each host computer To control two or more ports simultaneouslyTo upgrade AdderView CATxIP 1000 models Recovering from a failed upgradeTo invoke backup/recovery mode Upgrading AdderView CATxIP 1000 modelsFront panel indicators Accessing the AdderView CATxIPSelecting a computer Local user accessSelect Host menu here you can select computers by name To select a computer using the Select Host menuStandard hotkeys To select a computer using mouse buttons Advanced method To select a computer using mouse buttonsLogging in and out To logTo change banner colours or disable the banner To enable/disable the confirmation boxConfirmation box Reminder bannerUser preferences and functions Blue dot indicators in the Select Host menuGlobal User Global user accessTo access via the VNC viewer Global user access via VNC viewerTo download the VNC viewer Options buttonTo access via your web browser Global user access via web browserMenu bar Using the viewer windowWhen using the viewer window Mouse pointers ConfigureHost selection To select a hostPower switching Access mode shared/privateAuto calibrate Re-synchronise mouseControls Video Settings When entering codesKeyboard Control EnterIncreased by 50% when a slow link is detected Using automatic configurationsSetting the Threshold manually AccordinglyOverlap Capture Advanced SettingsCustom Video Modes Supported web browsers Viewer encryption settingsIf you need to enter a port number When logging on using VNC viewer, I cannot enter a username TroubleshootingGetting assistance US +1 888 275To access the local setup menus Appendix 1 Local setup menusRestore Standard Mouse Power ControlRestore Intellimouse FunctionsReminder Banner User PreferencesReminder Colour Screen SaverUser Timeout Mouse SwitchingGlobal Preferences OSD Dwell TimeAuto Logout Setup OptionsIP admin password, encryption settings, etc ConfigurationCompletely resets the AdderView CATxIP 1000 unit IP address, net mask, VNC port, etcUnit Configuration Network Configuration Settings Power Control, Sync Units Serial ConfigurationSettings 1200, 2400, 4800, 9600, 19200, 38400, 57600 Options PortTo reset the AdderView CATxIP 1000 configuration Reset ConfigurationMain configuration Logged on users Appendix 2 Configuration pages via viewerTo access the remote configuration pages User accounts Unit configuration Advanced unit configuration Time & date configuration IP Access Control Network configurationIP Network Mask IP GatewayTo define a new IP access control entry Setting IP access controlTo reorder access control entries To edit/remove access control entriesBaud Rate Serial port configurationOptions Port Use Erase Host Configuration Host configurationAdd entry for unrecognised host To create a new host entryTo copy and paste the log Logging and statusSyslog Server IP Address For further details To get hereLdap configuration Colour/Encoding Appendix 3 VNC viewer connection optionsAuto select Preferred encodingDisable all inputs view-only mode Enable all inputsInputs CustomiseMisc No Scaling ScalingScale to Window Size Custom SizeDefaults Save Defaults ReloadIdentities Load / SaveAppendix 4 VNC viewer window options Security Appendix 5 Browser viewer optionsEncoding and colour level Net masks Appendix 6 Addresses, masks and portsIP addresses Operation with net mask Net masks the binary explanationBinary equivalent Binary octet afterSingle locations Calculating the mask for IP access controlAll locations Address rangesPorts Security issues with portsPower switch to power switch daisy chain cable Appendix 7 Cable and connector specificationsAdderView CATxIP 1000 to power switch cable Creating macro sequences Appendix 8 Hotkey sequence codesPermissible key presses Appendix 9 Supported video modes General Public License Linux WarrantySafety information End user licence agreement European EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States Canadian Department of Communications RFI statementHoe Huat Industrial Building Index 