Adder Technology CATxIP 1000 manual Network configuration, IP Network Mask, IP Gateway

Page 67

Network configuration

This page allows you to configure the various aspects of the IP port and its relationship with the local network.

MAC address

Media Access Control address – this is the unique and unchangeable code that was hard coded within your AdderView CATxIP 1000 unit when it was built. It consists of six 2-digit hexadecimal (base 16) numbers separated by colons. A section of the MAC address identifies the manufacturer, while the remainder is effectively the unique electronic serial number of your particular unit.

Use DHCP

DHCP is an acronym for ‘Dynamic Host Configuration Protocol’. Its function is particularly useful when connecting to medium size or larger networks, such as the Internet. When this option is selected, your AdderView CATxIP 1000 will attempt to locate a DHCP server on the network. If such a server is located, it will supply three things to the AdderView CATxIP 1000: an IP address, an IP network mask (also known as a Subnet mask) and a Gateway address. These are not usually granted permanently, but on a ‘lease’ basis for a fixed amount of time or for as long as the AdderView CATxIP 1000 remains connected and switched on. Discover allocations.

To get here

1Using VNC viewer or a browser, log on as the ‘admin’ user.

2Click the ‘Configure’ button in the top right corner.

3Click the ‘Network Configuration’ option.

IP Address

This is the identity of the AdderView CATxIP 1000 within a network. The IP address can be thought of as the telephone number of the AdderView CATxIP 1000. Unlike the MAC address, the IP address can be altered to suit the network to which it is connected. It can either be entered manually or configured automatically using the DHCP option. When the DHCP option is enabled, this entry is greyed out.

IP Network Mask

Also often called the subnet-mask, this value is used alongside the IP address to help define a smaller collection (or subnet) of devices on a network. In this way a distinction is made between locally connected devices and ones that are reachable elsewhere, such as on the wider Internet. This process helps to reduce overall traffic on the network and hence speed up connections in general.

IP Gateway

This is the address of the device that links the local network (to which the AdderView CATxIP 1000 is connected) to another network such as the wider Internet. Usually the actual gateway is a network switch or router and it will be used whenever a required address lies outside the current network.

VNC Port

This is the logical link through which communications with a remote VNC viewer will be channelled (see What is a port?). The default setting is 5900 which is

a widely recognised port number for use by VNC software. However, in certain circumstances it may be advantageous to alter this number - see ‘Security issues with ports’ for more details.

HTTP Port

This is the logical link through which communications with a remote web browser will be channelled (see What is a port?). The default setting of 80 is an established standard for web (HTTP – HyperText Transfer Protocol) traffic though this can be changed to suit your local network requirements.

IP Access Control

This section allows you to optionally specify ranges of addresses which will or won’t be granted access to the AdderView CATxIP 1000. If this option is left unchanged, then the default entry of ‘+0.0.0.0/0.0.0.0’ ensures that access from all IP addresses will be permitted. See Setting IP access control for details.

   



66

Image 67
Contents AdderView CATxIP Contents Further information Index Many computers Global usersCAM formats AdderView CATxIP 1000 features front and rear What you may additionally need What’s in the boxSingle unit rack brackets MountingDouble unit rack brackets Connections CAM Computer Power System SwitchTo connect the local user port Local userCategory 5, 5e or 6 cable from Adder X100/X200 module Global user IP network portTo connect the Global user IP network port AdderView CATxIP Front panelTo connect a computer system Computer system via CAMTo connect the power supply Power in connectionOutput lead from Power adapter To connect and address the switch boxes Power control portSwitch See also Cascading multiple unitsCascade tree Tips for successful cascading Connecting units in cascadeTo connect units in cascade Addressing computers in a cascade Using cascaded computersIt is recommended that Second CAM in each pair is a Multiple video head connectionsUSB-type and that it is plugged Host computer port/channel Video off Remote switching controlCable from serial Control device Overall initial configuration ConfigurationInitial configuration Security Main menuMenu layout HotkeysRegistering users and host computers General security and configuration stepsTo enable general security To set an Admin passwordTo clear a password and restore factory default settings What to do if the Admin password has been forgottenWhat is IP access control? Clearing IP access controlTo clear IP access control To configure the unit from a global user location Full configuration by global userAdderView CATxIP 1000 encryption settings Encryption settingsViewer encryption settings Positioning AdderView CATxIP 1000 in the network Networking issuesFirewall/router address Port settingsPlacing AdderView CATxIP 1000 behind a router or firewall AddressingDNS addressing To discover a DHCP-allocated IP addressEnsuring sufficient security Placing AdderView CATxIP 1000 alongside the firewallPorts To control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerUpgrading AdderView CATxIP 1000 models Recovering from a failed upgradeTo upgrade AdderView CATxIP 1000 models To invoke backup/recovery modeFront panel indicators Accessing the AdderView CATxIPSelecting a computer Local user accessStandard hotkeys To select a computer using the Select Host menuSelect Host menu here you can select computers by name To log To select a computer using mouse buttonsTo select a computer using mouse buttons Advanced method Logging in and outReminder banner To enable/disable the confirmation boxTo change banner colours or disable the banner Confirmation boxUser preferences and functions Blue dot indicators in the Select Host menuGlobal User Global user accessOptions button Global user access via VNC viewerTo access via the VNC viewer To download the VNC viewerTo access via your web browser Global user access via web browserWhen using the viewer window Using the viewer windowMenu bar To select a host ConfigureMouse pointers Host selectionRe-synchronise mouse Access mode shared/privatePower switching Auto calibrateControls Enter When entering codesVideo Settings Keyboard ControlAccordingly Using automatic configurationsIncreased by 50% when a slow link is detected Setting the Threshold manuallyCustom Video Modes Advanced SettingsOverlap Capture If you need to enter a port number Viewer encryption settingsSupported web browsers US +1 888 275 TroubleshootingWhen logging on using VNC viewer, I cannot enter a username Getting assistanceTo access the local setup menus Appendix 1 Local setup menusFunctions Power ControlRestore Standard Mouse Restore IntellimouseScreen Saver User PreferencesReminder Banner Reminder ColourOSD Dwell Time Mouse SwitchingUser Timeout Global PreferencesAuto Logout Setup OptionsIP address, net mask, VNC port, etc ConfigurationIP admin password, encryption settings, etc Completely resets the AdderView CATxIP 1000 unitUnit Configuration Network Configuration Options Port Serial ConfigurationSettings Power Control, Sync Units Settings 1200, 2400, 4800, 9600, 19200, 38400, 57600To reset the AdderView CATxIP 1000 configuration Reset ConfigurationTo access the remote configuration pages Appendix 2 Configuration pages via viewerMain configuration Logged on users User accounts Unit configuration Advanced unit configuration Time & date configuration IP Gateway Network configurationIP Access Control IP Network MaskTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesOptions Port Use Serial port configurationBaud Rate To create a new host entry Host configurationErase Host Configuration Add entry for unrecognised hostFor further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressLdap configuration Preferred encoding Appendix 3 VNC viewer connection optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc Custom Size ScalingNo Scaling Scale to Window SizeLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Encoding and colour level Appendix 5 Browser viewer optionsSecurity IP addresses Appendix 6 Addresses, masks and portsNet masks Binary octet after Net masks the binary explanationOperation with net mask Binary equivalentAddress ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with portsAdderView CATxIP 1000 to power switch cable Appendix 7 Cable and connector specificationsPower switch to power switch daisy chain cable Permissible key presses Appendix 8 Hotkey sequence codesCreating macro sequences Appendix 9 Supported video modes Safety information WarrantyGeneral Public License Linux End user licence agreement Canadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesHoe Huat Industrial Building Index 