Initial configuration

The AdderView CATxIP 1000 unit provides an initial configuration . sequence to assist you to make the necessary settings.

When the AdderView CATxIP 1000 is switched on for the first time, you should see the unit configuration screen, as shown here

IMPORTANT: Complete the initial IP configuration and invoke security measures BEFORE the unit is connected to an open IP network.

If the AdderView CATxIP 1000 unit has been previously configured, . it will display either the Login dialog or the Select Host screen, .

as shown here

  

If the Login is shown, enter

 

 

 



 

 

your ‘admin’ Username and

 

 

 

 

Password - or press

twice if



none have yet been defined.

 

   

 



 





 



 



 

 

 

 

 

 

 

 

 





 



 

 

 

 

 

 

 

 

1





 

 

 

 

 

 

 

 

 

 

 

 





 

 

 

 

 

 

 

 

 

 

 

 

 



 

 

 



 

 





 

 

 

 

 



 

 

 



 

 

 



 



 

 



 





 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



 



 

 



 

 

 

 



 

 

 

 

 

 

 

 

 

 

 



 

 

 

 

 

2

 

 



 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

Admin password

Enter a password of at least six characters that has a mix of letters and numerals. The background colour provides an indication of password suitability and is initially red to indicate that the password is not sufficient. When a password with reasonable strength has been entered it will change to green.

Time and Date

Set these correctly as all entries in the activity log are time stamped using them.

Encryption

See Encryption settings for a description of the issues and the settings.

Use DHCP/IP address/Net Mask/Gateway

You need to either set the DHCP option to ‘Yes’ or manually enter a valid IP address, Net mask and Gateway. See Networking issues for more details.

VNC and HTTP ports

 

 

 

 

 



 









 



 

 



 

  



These should remain set to 5900 and 80, respectively, unless they clash with an existing setup within the network. See Networking issues for more details.

 



 



 

 



 



 



 



 









 





   

 

  

  

From the Select Host screen, press to display the Main Menu. See Main Menu for more details.

   

      

3

Option port (serial) details

These two items control the use of the OPTIONS port on the rear panel of the unit. The port can either be used to control optional power switching devices or can be used to synchronise the operation of two separate AdderView CATxIP 1000 units.

If neither of these features are required, then you do not need to change anything on this screen.

 

   



      



Within the Main Menu, use the and keys to highlight an option, then press to select.

The Configuration option provides access to separate Unit, Network and Serial Configuration screens that are similar in function to the first three setup screens shown on the right.

   



   

           

4        



   

Secure keys generation

With every mouse move and keypress, the single dash will move across the screen (unless the same key is pressed repeatedly). Periodically, a new star character will be added to the bar as the random data are accepted as part of the new encryption key. When the bar is full, the final encryption keys for your AdderView CATxIP 1000 will be created – this process takes roughly 30 to 40 seconds. Once the secure keys have been calculated the AdderView CATxIP 1000 will show either the Login dialog or Select Host screen.



Note: Screen 5 of 5 is displayed while

 

the secure keys are being generated.

20

 

Image 21
Contents AdderView CATxIP Contents Further information Index Global users Many computersCAM formats AdderView CATxIP 1000 features front and rear What you may additionally need What’s in the boxMounting Single unit rack bracketsDouble unit rack brackets Connections CAM Computer Power System SwitchTo connect the local user port Local userTo connect the Global user IP network port Global user IP network portAdderView CATxIP Front panel Category 5, 5e or 6 cable from Adder X100/X200 moduleTo connect a computer system Computer system via CAMPower in connection To connect the power supplyOutput lead from Power adapter Power control port To connect and address the switch boxesSwitch Cascading multiple units See alsoCascade tree Connecting units in cascade Tips for successful cascadingTo connect units in cascade Addressing computers in a cascade Using cascaded computersMultiple video head connections It is recommended that Second CAM in each pair is aUSB-type and that it is plugged Remote switching control Host computer port/channel Video offCable from serial Control device Overall initial configuration ConfigurationInitial configuration Menu layout Main menuHotkeys SecurityTo enable general security General security and configuration stepsTo set an Admin password Registering users and host computersTo clear a password and restore factory default settings What to do if the Admin password has been forgottenClearing IP access control What is IP access control?To clear IP access control To configure the unit from a global user location Full configuration by global userEncryption settings AdderView CATxIP 1000 encryption settingsViewer encryption settings Positioning AdderView CATxIP 1000 in the network Networking issuesPlacing AdderView CATxIP 1000 behind a router or firewall Port settingsAddressing Firewall/router addressDNS addressing To discover a DHCP-allocated IP addressPlacing AdderView CATxIP 1000 alongside the firewall Ensuring sufficient securityPorts Power control sequences Power switching configurationTo configure the power sequences for each host computer To control two or more ports simultaneouslyTo upgrade AdderView CATxIP 1000 models Recovering from a failed upgradeTo invoke backup/recovery mode Upgrading AdderView CATxIP 1000 modelsFront panel indicators Accessing the AdderView CATxIPSelecting a computer Local user accessTo select a computer using the Select Host menu Standard hotkeysSelect Host menu here you can select computers by name To select a computer using mouse buttons Advanced method To select a computer using mouse buttonsLogging in and out To logTo change banner colours or disable the banner To enable/disable the confirmation boxConfirmation box Reminder bannerUser preferences and functions Blue dot indicators in the Select Host menuGlobal User Global user accessTo access via the VNC viewer Global user access via VNC viewerTo download the VNC viewer Options buttonTo access via your web browser Global user access via web browserUsing the viewer window When using the viewer windowMenu bar Mouse pointers ConfigureHost selection To select a hostPower switching Access mode shared/privateAuto calibrate Re-synchronise mouseControls Video Settings When entering codesKeyboard Control EnterIncreased by 50% when a slow link is detected Using automatic configurationsSetting the Threshold manually AccordinglyAdvanced Settings Custom Video ModesOverlap Capture Viewer encryption settings If you need to enter a port numberSupported web browsers When logging on using VNC viewer, I cannot enter a username TroubleshootingGetting assistance US +1 888 275To access the local setup menus Appendix 1 Local setup menusRestore Standard Mouse Power ControlRestore Intellimouse FunctionsReminder Banner User PreferencesReminder Colour Screen SaverUser Timeout Mouse SwitchingGlobal Preferences OSD Dwell TimeAuto Logout Setup OptionsIP admin password, encryption settings, etc ConfigurationCompletely resets the AdderView CATxIP 1000 unit IP address, net mask, VNC port, etcUnit Configuration Network Configuration Settings Power Control, Sync Units Serial ConfigurationSettings 1200, 2400, 4800, 9600, 19200, 38400, 57600 Options PortTo reset the AdderView CATxIP 1000 configuration Reset ConfigurationAppendix 2 Configuration pages via viewer To access the remote configuration pagesMain configuration Logged on users User accounts Unit configuration Advanced unit configuration Time & date configuration IP Access Control Network configurationIP Network Mask IP GatewayTo define a new IP access control entry Setting IP access controlTo reorder access control entries To edit/remove access control entriesSerial port configuration Options Port UseBaud Rate Erase Host Configuration Host configurationAdd entry for unrecognised host To create a new host entryTo copy and paste the log Logging and statusSyslog Server IP Address For further details To get hereLdap configuration Colour/Encoding Appendix 3 VNC viewer connection optionsAuto select Preferred encodingDisable all inputs view-only mode Enable all inputsInputs CustomiseMisc No Scaling ScalingScale to Window Size Custom SizeDefaults Save Defaults ReloadIdentities Load / SaveAppendix 4 VNC viewer window options Appendix 5 Browser viewer options Encoding and colour levelSecurity Appendix 6 Addresses, masks and ports IP addressesNet masks Operation with net mask Net masks the binary explanationBinary equivalent Binary octet afterSingle locations Calculating the mask for IP access controlAll locations Address rangesPorts Security issues with portsAppendix 7 Cable and connector specifications AdderView CATxIP 1000 to power switch cablePower switch to power switch daisy chain cable Appendix 8 Hotkey sequence codes Permissible key pressesCreating macro sequences Appendix 9 Supported video modes Warranty Safety informationGeneral Public License Linux End user licence agreement European EMC directive 89/336/EEC Radio Frequency EnergyFCC Compliance Statement United States Canadian Department of Communications RFI statementHoe Huat Industrial Building Index 