Using the Command Line Interface
Command Usage
Messages sent include the selected level down to Emergency level.
Level Argument | Description |
|
|
Emergency | System unusable |
Alert | Immediate action needed |
Critical | Critical conditions (e.g., memory allocation, or free memory error - resource |
| exhausted) |
Error | Error conditions (e.g., invalid input, default used) |
Warning | Warning conditions (e.g., return false, unexpected return) |
Notice | Normal but significant condition, such as cold start |
Informational | Informational messages only |
Debug | Debugging messages |
|
|
Example
Outdoor 11a Building to Building (config)#logging level alert Outdoor 11a Building to Building (config)#
logging facility-type
This command sets the facility type for remote logging of syslog messages.
Syntax
logging facility-type <type>
type - A number that indicates the facility used by the syslog server to dispatch log messages to an appropriate service. (Range:
Default Setting
16
Command Mode
Global Configuration
Command Usage
The command specifies the facility type tag sent in syslog messages. (See RFC 3164.) This type has no effect on the kind of messages reported by the access point. However, it may be used by the syslog server to sort messages or to store messages in the corresponding database.