Metrologic Instruments MS6130 MX003 Installation of the 6000 Series Universal Charging Stand

Page 26

INSTALLATION OF THE 6000 SERIES UNIVERSAL CHARGING STAND

MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK)

Transformer

Green LED

(Charge Status)

Red LED

(Power)

Figure 6: Universal Charging Stand

PERMANENT COUNTER TOP INSTALLATION

1.Separate weighted base from rotating base by removing the (4) four screws.

2.Use the rotating base as a drill template.

3.Use the (4) four wood screws provided to mount the base to the counter top securely.

4.Snap the cup assembly to the base.

Note: For non-permanent installation, snap the cup assembly onto the weighted base

CHARGE STATE

CHARGE LED STATUS

 

 

Battery Absent

LED off

 

 

Charge Pending

LED on for 0.125sec,

off for 1.375sec

 

 

 

Fast-Charge

LED on

 

 

Charge Complete and Top-Off

LED on for 0.125 sec,

off for 0.125sec

 

 

 

 

 

22

Image 26
Contents Metrologic INSTRUMENTS, INC Table of Contents Table of Contents Printer Note Leave page blank MS6130 Hand Held BAR Code Scanner MX003 Series Scanner Interfaces Receiver Group Unpacking ListTransmitter Group Connections of the Mxnterfacei to the Host Device Except versionConnections of the Keyboard Wedge Mxnterfacei to the PC Version 17 onlyConnections of the MS700I/MS720I With Mxto the Host Device Configuration of the MS700I/MS720I with MX Page Configuration of the Mxto the Scanpal Data Collector Page Keyboard Wedge KB Interface KB Parameter Keyboard TypeKB Parameter Keyboard Type KB Parameter Caps Lock Mode Millisecond Delay KB Parameter Alt ModeMicrosecond Delay Millisecond Delay KB Parameter XT Clean-Up BitConfiguration of the MS6130 HAND-HELD Enabling the MS700I/MS720I SCANNER’S RF LOW Speed Option Changing the ID Handset /XMatching Procedure Parts of the MS6130 HAND-HELD BAR Code Scanner Output WindowComponents of the MS6130 Series Stand Installation of the MS6130 Series Stand Installation of the 6000 Series Universal Charging Stand Permanent Counter TOP InstallationNicd Battery Charger with Reconditioning Feature Recommended USEVisual Indicators Razzberry Tone Audible IndicatorsOne Beep Two BeepsAudible Indicators Maintenance LabelsTroubleshooting Specifications Appendix aMX003 Series Scanner Interface Specifications Temperature Characteristics Degrees Celsius of each Cell Default Settings of the MS6130 and MX Receiver Appendix BRTS/CTS UPC EAN Parameter Transmitter Default Keyboard Receiver Wedge Pin Function Appendix CMX003 Series Scanner Interface Pin Assignments Appendix E Appendix F PatentsIndex ESDTroubleshooting