Cino FM400 manual EAN Setting , Supplement , Supplement Scan Voting, EAN Supplement Setting

Page 25

Mount

Manual

FuzzyScanFixed

Programming

 

Scan

 

 

Symbology Reading Control

EAN Setting , Supplement , Supplement Scan Voting

￿ The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed, low contrast or damage barcode labels.

PROGRAM

 

 

 

 

 

 

 

 

 

 

 

 

F_DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Family Code Selection

 

P.C

 

 

 

Parameter Selection

 

 

Option Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EAN Setting

 

SS

 

 

Disable EAN-13

 

 

 

 

 

0

 

 

 

 

 

Enable EAN-13 ￿

 

 

 

 

 

 

 

 

 

 

SS

 

 

 

 

 

 

 

1

 

 

 

SS

 

 

Disable EAN-8

 

 

 

 

 

2

 

 

 

SS

 

 

Enable EAN-8 ￿

 

 

 

 

 

3

 

 

 

SS

 

 

Disable EAN-8 expansion ￿

 

 

 

 

 

4

 

 

 

SS

 

 

Enable EAN-8 expansion

 

 

 

 

 

5

 

 

 

SS

 

 

Disable EAN-13 check digit transmission

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS

 

 

Enable EAN-13 check digit transmission ￿

 

 

 

 

7

 

 

 

SS

 

 

Disable EAN-8 check digit transmission

 

 

 

 

 

8

 

 

 

SS

 

 

Enable EAN-8 check digit transmission ￿

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS

 

 

Disable ISBN/ISSN Conversion reading check ￿

 

 

 

 

A

 

 

 

SS

 

 

Enable ISBN/ISSN Conversion reading check

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EAN Supplement Setting

 

SS

 

 

Select EAN without supplement digits ￿

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS

 

 

Select EAN with only 2 supplement digits

 

 

 

 

 

1

 

 

 

SS

 

 

Select EAN with only 5 supplement digits

 

 

 

 

 

2

 

 

 

SS

 

 

Select EAN with 2/5 supplement digits

 

 

 

 

 

3

 

 

 

SS

 

 

Disable force supplement digits output ￿

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS

 

 

Enable force supplement digits output

 

 

 

 

 

5

 

 

 

SS

 

 

EAN Addenda Separator Off ￿

 

 

 

 

 

6

 

 

 

SS

 

 

EAN Addenda Separator On

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supplement Scan Voting

 

SS

 

 

None

 

 

Level 7

 

0

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SS

 

 

Level 1

 

 

Level 8

 

1

 

8

 

 

 

SS

 

 

Level 2

 

 

Level 9

 

2

 

9

 

 

 

SS

 

 

Level 3 ￿

 

Level 10

 

3

 

A

 

 

SS

 

 

Level 4

 

Level 11

 

4

 

B

 

 

SS

 

 

Level 5

 

Level 12

 

5

 

C

 

 

SS

 

 

Level 6

 

Level 13

 

6

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

Image 25
Contents Fixed Mount Scanner Manual Warranty Table of Contents Getting Familiar with Your FuzzyScan USB Models FM4xx-11x Connect to Your HostAdjust Reading Angle Install Your FuzzyScanTest Button Use the Test ModeProgramming Use Your FuzzScanFixed Mount ProgrammingManual Bar Code Programming Menu System CommandProgramming Procedures Manual Single scan selection Multiple scans selection Cycling scan selection Dual level selection Family Code Selection Parameter Selection Host Interface SelectionUser Defined Symbol ID Symbology Reading ControlSymbol ID 1 character Option Code Symbology ID TransmissionReadable Symbology Setting Readable Bar Code SettingCode 39/Code 32 Setting Code 39 Setting Codabar/NW-7 Setting UPC Family Setting UPC-A & UPC-E SettingSupplement Scan Voting UPC-A & UPC-E Setting , Supplement Scan VotingEAN Supplement Setting EAN Setting , Supplement , Supplement Scan VotingEAN Supplement Control UPC/EAN Security Level SettingUPC/EAN Security Level EAN Supplement Control UCC Coupon Extended Code Setting Iata & Interleaved 2 of 5 Setting Code 25 Family Setting Code 11 & Code 93 Setting MSI/Plessey Setting Code 128 & UCC/EAN 128 Setting UK/Plessey Setting Telepen Setting GS1 DataBar Setting Linear-stacked & Korea Post Code Setting Keyboard Interface Control Keyboard Layout Language SettingKeyboard Layout Caps Lock Control Record Suffix, Preamble, Postamble & Caps LockDelay Setting Upper/Lower Case Emulation Setting & Upper/Lower Case SettingSerial Interface Control Record Suffix, Preamble, Postamble SettingDelay Setting Protocol, ACK/NAK Setting Serial Response Time-out Baud Rate BPS Data Frame Time Out Setting, Baud Rate, Data FrameOperation Control Operation Mode SettingGood Read Indicator Buzzer, Indicator, Inverse ReadingDollar Sign Control Redundancy Scan Rate Control Dollar Sign, Redundancy, Scan Rate ControlReread Delay Double San Verification Good Read Delay Scan Input Time-out Hands Free Time-out Good Read Duration Time-out and Duration SettingPresentation Sensitivity Presentation Scanning SettingOK/NG Signal and Beeping Control Programming Condensed DataWizard Preamble, Postamble, Data Length & Symbol ID TransFormatter Control Data Formatter SettingVerifier Control Data Verifier SettingReplacer Control Data Replacer SettingOrganizer Control Data Organizer SettingSelect a Bar Code Symbology Data Organizer Data ReplacerImportant Notice UPC UPC-E EAN/JAN EAN/JAN-13 Symbology ID TableKeyboard Function Code Table Example Ascii Input ShortcutHEX/ASCII Reference Table Host Interface Quick Set Operation Mode Quick SetOption Codes END System CommandsIndications Fixed Mount Scanner Programming Manual