Cino FM400 manual Record Suffix, Preamble, Postamble & Caps Lock, Caps Lock Control

Page 38

Mount

Manual

FuzzyScanFixed

Programming

 

Scan

 

 

Keyboard Interface Control

Record Suffix, Preamble, Postamble & Caps Lock

PROGRAM

 

 

 

 

 

 

 

F_DEFAULT

 

 

 

 

 

 

 

 

 

Family Code Selection

 

P.C

 

 

Parameter Selection

 

Option Code

 

 

 

 

 

 

 

 

 

Record Suffix

 

SS

 

 

None

 

0

 

 

 

 

RETURN ￿

 

 

 

 

SS

 

 

 

1

 

 

SS

 

 

TAB

 

2

 

 

SS

 

 

SPACE

 

3

 

 

SS

 

 

ENTER (Numeric Key Pad)

 

4

 

 

SS

 

 

User defined character (1 character)

 

5, (00-7F)

 

 

 

 

 

 

 

 

Preamble

 

SS

 

 

None ￿

 

FIN

 

 

 

 

 

 

 

 

 

 

MS

 

 

1-15 characters

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

 

 

 

Postamble

 

SS

 

 

None ￿

 

FIN

 

 

 

 

 

 

 

 

 

 

MS

 

 

1-15 characters

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

 

 

 

Caps Lock Control

 

SS

 

 

“Caps Lock Off” State ￿

 

0

 

 

 

 

 

 

 

 

 

 

SS

 

 

“Caps Lock On” State

 

1

 

 

SS

 

 

Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)

 

2

 

 

 

 

 

 

 

 

Caps Lock Release Control

 

SS

 

 

“Caps Lock On, Caps Off” ￿

 

0

 

 

 

 

 

 

 

 

 

 

SS

 

 

“Caps Lock On, Shift Off”

 

1

 

 

 

 

 

 

 

 

 

￿The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions for you.

￿Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.

34

Image 38
Contents Fixed Mount Scanner Manual Warranty Table of Contents Getting Familiar with Your FuzzyScan Connect to Your Host USB Models FM4xx-11xInstall Your FuzzyScan Adjust Reading AngleUse the Test Mode Test ButtonUse Your FuzzScan ProgrammingFixed Mount ProgrammingManual System Command Bar Code Programming MenuProgramming Procedures Manual Single scan selection Multiple scans selection Cycling scan selection Dual level selection Host Interface Selection Family Code Selection Parameter SelectionSymbol ID 1 character Symbology Reading ControlUser Defined Symbol ID Symbology ID Transmission Option CodeReadable Bar Code Setting Readable Symbology SettingCode 39/Code 32 Setting Code 39 Setting Codabar/NW-7 Setting UPC-A & UPC-E Setting UPC Family SettingUPC-A & UPC-E Setting , Supplement Scan Voting Supplement Scan VotingEAN Setting , Supplement , Supplement Scan Voting EAN Supplement SettingUPC/EAN Security Level EAN Supplement Control UPC/EAN Security Level SettingEAN Supplement Control UCC Coupon Extended Code Setting Iata & Interleaved 2 of 5 Setting Code 25 Family Setting Code 11 & Code 93 Setting MSI/Plessey Setting Code 128 & UCC/EAN 128 Setting UK/Plessey Setting Telepen Setting GS1 DataBar Setting Linear-stacked & Korea Post Code Setting Keyboard Layout Keyboard Layout Language SettingKeyboard Interface Control Record Suffix, Preamble, Postamble & Caps Lock Caps Lock ControlDelay Setting Emulation Setting & Upper/Lower Case Setting Upper/Lower CaseRecord Suffix, Preamble, Postamble Setting Serial Interface ControlDelay Setting Protocol, ACK/NAK Setting Time Out Setting, Baud Rate, Data Frame Serial Response Time-out Baud Rate BPS Data FrameOperation Mode Setting Operation ControlBuzzer, Indicator, Inverse Reading Good Read IndicatorDollar Sign, Redundancy, Scan Rate Control Dollar Sign Control Redundancy Scan Rate ControlReread Delay Double San Verification Good Read Delay Time-out and Duration Setting Scan Input Time-out Hands Free Time-out Good Read DurationPresentation Scanning Setting Presentation SensitivityOK/NG Signal and Beeping Control Programming Preamble, Postamble, Data Length & Symbol ID Trans Condensed DataWizardData Formatter Setting Formatter ControlData Verifier Setting Verifier ControlData Replacer Setting Replacer ControlData Organizer Setting Organizer ControlSelect a Bar Code Symbology Important Notice Data ReplacerData Organizer Symbology ID Table UPC UPC-E EAN/JAN EAN/JAN-13Keyboard Function Code Table HEX/ASCII Reference Table Ascii Input ShortcutExample Operation Mode Quick Set Host Interface Quick SetOption Codes System Commands ENDIndications Fixed Mount Scanner Programming Manual