1 Installing and Configuring the 82350

Example: Connecting Multiple GPIB Instruments

Figure 1- 9 shows one way to connect three GPIB instruments to an Agilent 82350 GPIB Interface Card. You may want to record the primary GPIB address of each attached instrument for future programming use. After making the connections, reconnect the PC power cord and apply power to the PC and attached peripherals/instruments.

To avoid damage to the connectors, only finger-tighten the CAUTION connectors.

N O T E

Although the figure shows cable connections to GPIB Instrument 1, the connection can be to any GPIB instrument in the system.

GPIB Connector. Connect to GPIB connector on 82350 Interface Card.

GPIB Cable

GPIB Connector. Connect to GPIB port on GPIB Instrument 1.

PC

Instrument 1

 

Instrument 2

Instrument 3

Figure 1-9Connecting multiple GPIB instruments

22

82350B Installation and Configuration Guide

Image 34
Contents PCI Gpib Manual Part Number Safety Notices Safety Symbols Page General Safety Information Environment Conditions Regulatory Markings Page Declaration of Conformity Contents Specifications and Information Installing and Configuring Getting Started 182350B system overviewBefore you install Check your shipmentWindows XP Service Pack 3 or later System requirements1Ghz 32- bit x86, 1GHz 64- bit x64, no support for Itanium64 Create an emergency repair disk Installing the Agilent IO Libraries Suite Checking for installed Agilent IO LibrariesInstalling and Configuring Installing Agilent IO Libraries Suite Click Start Run Installing and Configuring the 82350 If you accept the Typical Installation, click Next and pro Installing and Configuring the 82350 When you are done selecting features, click Next Installing and Configuring the 82350 T E Connecting your instruments Installing the 82350 in your PC4Remove the PC cover Connecting instruments to Installing and Configuring 8Connecting a single Gpib instrument Example Connecting Multiple Gpib Instruments Configuring Installing configuration filesConfiguring the 82350 interface 10Agilent Connection Experts11Configure Gpib card parameters System Installing and Configuring the 82350 Communicating with your instruments Verifying instrument communicationProgramming your instruments 12Agilent Interactive IOAccessing Programming Manuals and Help Example Gpib Interface Configuration 13Interface configuration for multiple instruments Troubleshooting Guidelines Troubleshooting Overview 1Troubleshooting overviewCheck cables/connections/power Hardware ChecksCheck Device Manager Number ffffffff Troubleshooting Guidelines 82350B Installation and Configuration Guide Disable Connection Expert Auto-Discovery Software Checks82350B Installation and Configuration Guide Set 82350 Read/Write Performance Mode 82350B Installation and Configuration Guide Troubleshooting Guidelines Check IO Libraries Suite installation Agilent IO Libraries Suite ChecksCheck IO Control operation Install IO Libraries Suite if 82350 was installed first Windows XP/Vista/7 Specifications Information General Requirements General Characteristics +5V PCIAccessing an Electronic Copy of this Guide Contacting Agilent URLSpecifications and Information Index GpibWeb sites, Agilent Contact us