Adder Technology CATX-USBA, X200AS/R Power control port, To connect and address the switch boxes

Page 16

Power control port

The AdderView CATx IP models provide a serial port for connection to one or

more optional power control units.

This allows you to control the mains power being supplied to the connected

computer(s) so that an authorised user

can, if necessary, perform a complete remote cold reboot on a failed system.

The control connector of the first power switch is attached, via serial cable, to the rear panel of the AdderView CATx IP. Any additional power switches are then attached via a ‘daisy-chain’ arrangement to the first power switch. Each power switch box is then given a unique address and access to each power port (8 ports on each power switch box) is gained using a combination of the switch box address and the port number.

‘Daisy-chain’

Power

control

switch

connections

boxes

Box 1

 

Box 2

Power to computer

Box 2, port 6 - address: 26

Box 3

Box 4

The power ports are connected to the power inputs of each computer system and the power switch box(es) are then connected to a mains power supply.

IMPORTANT: Power switching devices have a maximum current rating. It is essential to ensure that the total current drawn by the equipment connected to the power switching device does not exceed the current rating of the power switching device. You must also ensure that the current drawn from any mains socket does not exceed the current rating of the mains socket.

Setting up, configuring and using power switching requires three main steps:

Connect and address the switch boxes

Configure the power strings

Operate power switching via configuration menu or via viewer

To connect and address the switch boxes

Note: The AdderView CATx IP unit can be powered on during this procedure, however, the switch boxes should be switched off.

1Mount up to four switch boxes in positions where they are close to the computer systems that they will control and not too distant from the AdderView CATx IP unit (preferably within 2.5 metres).

2Use a serial cable with an RJ9 and a 9-pin D-type connector (see Appendix 7 for specification). Attach the RJ9 plug to the socket marked IN on the first switch box. Attach the other end to the socket marked POWER CONTROL on the AdderView CATx IP.

AdderView CATx

rear panel

Serial cable to first power switch box

3For each of the remaining switch boxes (if used), use a serial cable with RJ9 connectors at both ends (see Appendix 7 for specification). Attach one end to the socket marked OUT of the previous box and the other end to the socket marked IN of the next box.

4Set the addressing switches on each switch

box using the two micro switches marked Box Switch 1 Switch 2

‘Slct’ on the front panel. The box connected

1

Off

Off

directly to the AdderView CATx IP is Box 1

2

On

Off

and so on, down the daisy-chain line to Box

3

Off

On

4 at the end.

4

On

On

5 Attach IEC to IEC power leads between

Off = switch upwards

 

each port and the power input socket of

 

On = switch downwards

 

each computer system that requires power

Switch 1 is on the left side

 

switching. Carefully note to which power

 

 

 

ports, on which boxes, each computer system is connected. If computer systems have multiple power inputs, then each input must be connected via separate ports, which can be on the same, or different boxes.

6 Connect each box to a suitable mains power input.

Now proceed to the configuration stage covered in the Power switching configuration section within the Configuration chapter.

   



15

Image 16
Contents AdderView CATx Contents Auto calibrate Re-synchronise mouseIndex Introduction AdderView CATx features front and rear Front panel buttonsWhat’s in the box What you may additionally needRack brackets MountingConnections Remote switching Control ConnectionsModem Multiple video Isdn port Head connections Cascading Multiple unitsLocal user To connect the local user portCable lengths for remote user locations Remote user via X100/X200 extenderTo connect a remote user Global user IP network port To connect the Global user IP network portTo connect a computer system Computer system via CAMComputer video compensation for details Modem/ISDN port To connect a modem or Isdn adapterPower in connection To connect the power supplyPower control port To connect and address the switch boxesSystem, called Adder Port Direct Cascading multiple unitsSee also How cascade connections operate Addressing computers in a cascade CA02Tips for successful cascading Connecting AdderView CATx units in cascadeTo connect units in cascade Testing specific links to cascaded computers Using cascaded computersTo test a specific link Multiple video head connections Remote switching control Host computer port/channel Video offOverall initial configuration Configuration menus To access the configuration menu local and remote usersTo access the configuration menu global users HotkeysGeneral security and configuration steps Configuration menus layoutTo enable general security To set an Admin passwordRegistering users edit user list Access to all computers Press Access to no computers PressTo create/edit user accounts Registering computers edit computer list Tips when creating/editing computer entriesTo create/edit computer entries See Remote user skew adjustment for details Video compensationComputer video compensation To apply computer video compensationRemote user video compensation To display a suitable high contrast imageTo apply remote user video compensation If the image controls cannot provide a crisp imageRemote user skew adjustment To use skew adjustmentUsing the supplied skew pattern Creating a skew test patternNum Lock for Red, Caps Lock for Green To select an autoscan mode AutoscanningTo select an autoscan period To define an autoscan listPreparations for configuration save/load Saving and restoring configuration settingsTo transfer configuration settings To edit the configuration settings Hints for editingWhat to do if the Admin password has been forgotten To reset AdderView CATx modelsTo reset the AdderView CATx IP models Configuration screensWhich restore setting do I use? To restore mouse operation when hot pluggingHot plugging and mouse restoration Recognising an IntelliMouse-style mouseTo use the initial IP-configuration sequence Initial IP configurationTo configure IP-specific settings To configure IP details from a global user location IP configuration by global userUser Accounts AdderView CATx IP encryption settings Encryption settingsViewer encryption settings Networking issues Positioning AdderView CATx IP in the networkPlacing AdderView CATx IP behind a router or firewall Port settingsAddressing To discover a DHCP-allocated IP address DNS addressingBy configuration page via viewer Placing AdderView CATx IP alongside the firewallEnsuring sufficient security PortsPower switching configuration Power control sequencesTo configure the power sequences for each host computer To control two or more ports simultaneouslyKvmadmin utility Kvmadmin command ip address parametersKvmadmin -getconfig kvm1.cfg Kvmadmin -setusers users.csvPerforming upgrades Items required to use the upgrade utilityUpgrading AdderView CATx models and CAMs To use the KVM Firmware Uploader utilitySelect the items to be upgraded Select the upgrade file to be usedCommence the upgrade Issues to consider when performing flash upgradesTo upgrade AdderView CATx IP models Upgrading AdderView CATx IP modelsAccessing the AdderView CATx Front panel controlsAdderView CATx models AdderView CATx IP modelsLocal and remote user access To gain access as a local or remote userTo select a computer using the front panel controls Selecting a computerTo select a computer using hotkeys Standard hotkeysAbove or for even longer cascaded computers Keep Pressed down until all other Numbers have been enteredTo select a computer using mouse buttons To select a computer using the on-screen menuTo select a computer using mouse buttons Advanced method Selecting cascaded computers Logging in and outConfirmation box To change banner colours or disable the banner To use the Routing status featureReminder banner Routing statusTo switch a computer on or off Power switching via configuration menuUser preferences and functions Global user access To access via the VNC viewer Global user access via VNC viewerTo download the VNC viewer Global user access via web browser To access via your web browserWhen using the viewer window Using the viewer windowMenu bar Configure Mouse pointersHost selection To select a hostAccess mode shared/private Power switching via viewerAuto calibrate Re-synchronise mouseSingle Mouse Mode ControlsMouse Control Resync MouseWhen entering codes Video SettingsKVM switch menu Keyboard ControlUsing automatic configurations Increased by 50% when a slow link is detectedSetting the Threshold manually System informationAccess via dial up modem or Isdn link If you need to enter a port numberTo initiate a dial up link To enter a port number in a Web browserViewer encryption settings Supported web browsersWindows LinuxTroubleshooting When logging on using VNC viewer, I cannot enter a usernameGetting assistance US +1 888 275To access the configuration menus Appendix 1 Configuration menusConfigure IP port Functions User Preferences Mouse Switching Autoscan ModeGlobal Preferences Screen SaverUser Timeout OSD Dwell TimeRS232 Mouse Type Mouse TypeSetup Options Keypad ControlsLanguage Exclusive UseSettings AUTO, Manual Automatic LogoutAudio Add ComputersDDC Source Settings AUTO, LOCAL, Default DDC Refresh Settings AT START, DisabledAdvanced Options DDC OptionsCountry Code Settings AUTO, MANUAL, Disabled Default CountrySetup Options Force Mode Settings DISABLED, EnabledConfigure IP port IP admin password, encryption settings, etcIP address, net mask, VNC port, etc Baud rate, initialisation string, etcUnit Configuration Network Configuration Modem Configuration Clearing IP access control Reset ConfigurationTo reset the AdderView CATx IP configuration What is IP access control?Appendix 2 Configuration pages via viewer To access the remote configuration pagesUser accounts Unit configuration Admin PasswordHardware Version Firmware VersionAdvanced unit configuration Time & date configuration Network configuration IP Access ControlIP Network Mask IP GatewaySetting IP access control To define a new IP access control entryTo reorder access control entries To edit/remove access control entriesPower control port Serial port configurationModem port Host configuration Erase Host ConfigurationAdd entry for unrecognised host To create a new host entryAdder Port Direct Port/host addressing using Adder Port DirectExamples Logging and status To copy and paste the logSyslog Server IP Address For further details To get hereAppendix 3 VNC viewer connection options Colour/EncodingAuto select Preferred encodingEnable all inputs Disable all inputs view-only modeInputs CustomiseScaling MiscDefaults Reload Defaults SaveIdentities Load / SaveAppendix 4 VNC viewer window options Encoding and colour level Appendix 5 Browser viewer optionsSecurity Appendix 6 Addresses, masks and ports IP addressesNet masks Want to know more?154 Net masks the binary explanationCalculating the mask for IP access control Single locationsAll locations Address rangesSecurity issues with ports PortsPower switch to power switch daisy chain cable Appendix 7 Cable and connector specificationsRS232 serial flash upgrade cable Multi-head synchronisation cable Permissible key presses Appendix 8 Hotkey sequence codesCreating macro sequences Appendix 9 Supported video modes Safety information WarrantyGeneral Public License Linux End user licence agreement Radio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statement111 Index 113 114