Advanced unit configuration

Click this button to display advanced options that do not normally require alteration.

To get here

1Using VNC viewer or a browser, log on as the ‘admin’ user.

2Click the ‘Configure’ button in the top right corner.

3Click the ‘Unit configuration’ option.

4Click the ‘Advanced unit configuration’ option.

Force VNC Protocol 3.3

IMPORTANT: The use of this option is not recommended. Protocol 3.3 is a legacy version that does not offer any encryption.

Idle Timeout

Determines the period of inactivity on a global connection before the user is logged out. The idle timeout period can be set to any time span, expressed in minutes. Note: The Screensaver option serves a similar purpose for local connections.

Protocol Timeout

Sets the time period by which responses should have been received to outgoing data packets. If the stated period is exceeded, then a connection is considered lost and terminated.

Mouse Latency Allowance

This option is used during calibration to account for latency delays (caused as signals pass through a device) introduced by some KVM switches from alternative manufacturers.

During calibration, the AdderView CATx waits for 40ms after each mouse movement before sampling the next. If a KVM device adds a significant delay to the flow of data, the calibration process can be lengthened or may fail entirely. The value entered here is added to (or subtracted from) the default 40ms sampling time.

Note: You can enter negative values (down to -40) in order to speed up the calibration process when using fast KVM switches. Use this option with caution as it can adversely affect the calibration process.

Mouse Rate

Defines the rate at which mouse movement data are transmitted to the system. The default option is 20ms, which equates to 50 mouse events per second. This default rate can prove too fast when passed through certain connected KVM switches from alternative manufacturers. In such cases, data are discarded causing the local and remote mouse pointers to drift apart. If this effect is encountered, increase the mouse rate to around 30ms (data are then sent at a slower rate of 33 times per second).

Background Refresh Rate

Use the arrow keys to alter the refresh rate for screen images via remote links. This allows you to tailor the screen refresh to suit the network or modem connection speeds. The options are: Slow, Medium, Fast or Disabled. When the disabled option is selected, the remote users will need to manually refresh the screen.

Note: When a low connection speed is detected, the background refresh is automatically disabled, regardless of the settings of this option.

Single Mouse Mode Mouse Switch

Allows you to select the mouse button combination that can be used to exit from single mouse mode (when active).

Behaviour for admin connections when limit reached

Determines what should occur when four global connections already exist and a fifth, administrator connection attempt is made. Options are: Replace oldest connection, Replace newest connection and Don’t replace. Only non-administrator connections can be terminated in this way.

Use VESA GTF

When ticked, the VESA Generalized Timing Formula will be used to help determine the correct input video resolution and timing details. See Appendix 9 for a list of all supported video modes.

Upgrade firmware

Places the unit into upgrade mode. See Upgrading AdderView CATx IP models.

   



86

Image 87
Contents AdderView CATx Contents Re-synchronise mouse Auto calibrateIndex Introduction Front panel buttons AdderView CATx features front and rearWhat you may additionally need What’s in the boxMounting Rack bracketsConnections Cascading Multiple units Remote switching ControlConnections Modem Multiple video Isdn port Head connectionsTo connect the local user port Local userRemote user via X100/X200 extender Cable lengths for remote user locationsTo connect a remote user To connect the Global user IP network port Global user IP network portComputer system via CAM To connect a computer systemComputer video compensation for details To connect a modem or Isdn adapter Modem/ISDN portTo connect the power supply Power in connectionTo connect and address the switch boxes Power control portCascading multiple units System, called Adder Port DirectSee also How cascade connections operate CA02 Addressing computers in a cascadeConnecting AdderView CATx units in cascade Tips for successful cascadingTo connect units in cascade Using cascaded computers Testing specific links to cascaded computersTo test a specific link Multiple video head connections Host computer port/channel Video off Remote switching controlOverall initial configuration Hotkeys Configuration menusTo access the configuration menu local and remote users To access the configuration menu global usersTo set an Admin password General security and configuration stepsConfiguration menus layout To enable general securityAccess to all computers Press Access to no computers Press Registering users edit user listTo create/edit user accounts Tips when creating/editing computer entries Registering computers edit computer listTo create/edit computer entries Video compensation See Remote user skew adjustment for detailsTo apply computer video compensation Computer video compensationIf the image controls cannot provide a crisp image Remote user video compensationTo display a suitable high contrast image To apply remote user video compensationCreating a skew test pattern Remote user skew adjustmentTo use skew adjustment Using the supplied skew patternNum Lock for Red, Caps Lock for Green To define an autoscan list To select an autoscan modeAutoscanning To select an autoscan periodSaving and restoring configuration settings Preparations for configuration save/loadTo transfer configuration settings Hints for editing To edit the configuration settingsConfiguration screens What to do if the Admin password has been forgottenTo reset AdderView CATx models To reset the AdderView CATx IP modelsRecognising an IntelliMouse-style mouse Which restore setting do I use?To restore mouse operation when hot plugging Hot plugging and mouse restorationInitial IP configuration To use the initial IP-configuration sequenceTo configure IP-specific settings IP configuration by global user To configure IP details from a global user locationUser Accounts Encryption settings AdderView CATx IP encryption settingsViewer encryption settings Positioning AdderView CATx IP in the network Networking issuesPort settings Placing AdderView CATx IP behind a router or firewallAddressing DNS addressing To discover a DHCP-allocated IP addressPorts By configuration page via viewerPlacing AdderView CATx IP alongside the firewall Ensuring sufficient securityTo control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerKvmadmin -setusers users.csv Kvmadmin utilityKvmadmin command ip address parameters Kvmadmin -getconfig kvm1.cfgTo use the KVM Firmware Uploader utility Performing upgradesItems required to use the upgrade utility Upgrading AdderView CATx models and CAMsIssues to consider when performing flash upgrades Select the items to be upgradedSelect the upgrade file to be used Commence the upgradeUpgrading AdderView CATx IP models To upgrade AdderView CATx IP modelsAdderView CATx IP models Accessing the AdderView CATxFront panel controls AdderView CATx modelsSelecting a computer Local and remote user accessTo gain access as a local or remote user To select a computer using the front panel controlsKeep Pressed down until all other Numbers have been entered To select a computer using hotkeysStandard hotkeys Above or for even longer cascaded computersTo select a computer using the on-screen menu To select a computer using mouse buttonsTo select a computer using mouse buttons Advanced method Logging in and out Selecting cascaded computersConfirmation box Routing status To change banner colours or disable the bannerTo use the Routing status feature Reminder bannerPower switching via configuration menu To switch a computer on or offUser preferences and functions Global user access Global user access via VNC viewer To access via the VNC viewerTo download the VNC viewer To access via your web browser Global user access via web browserUsing the viewer window When using the viewer windowMenu bar To select a host ConfigureMouse pointers Host selectionRe-synchronise mouse Access mode shared/privatePower switching via viewer Auto calibrateResync Mouse Single Mouse ModeControls Mouse ControlKeyboard Control When entering codesVideo Settings KVM switch menuSystem information Using automatic configurationsIncreased by 50% when a slow link is detected Setting the Threshold manuallyTo enter a port number in a Web browser Access via dial up modem or Isdn linkIf you need to enter a port number To initiate a dial up linkLinux Viewer encryption settingsSupported web browsers WindowsUS +1 888 275 TroubleshootingWhen logging on using VNC viewer, I cannot enter a username Getting assistanceAppendix 1 Configuration menus To access the configuration menusConfigure IP port Functions User Preferences Screen Saver Mouse SwitchingAutoscan Mode Global PreferencesMouse Type User TimeoutOSD Dwell Time RS232 Mouse TypeExclusive Use Setup OptionsKeypad Controls LanguageAdd Computers Settings AUTO, ManualAutomatic Logout AudioDDC Options DDC Source Settings AUTO, LOCAL, DefaultDDC Refresh Settings AT START, Disabled Advanced OptionsForce Mode Settings DISABLED, Enabled Country Code Settings AUTO, MANUAL, DisabledDefault Country Setup OptionsBaud rate, initialisation string, etc Configure IP portIP admin password, encryption settings, etc IP address, net mask, VNC port, etcUnit Configuration Network Configuration Modem Configuration What is IP access control? Clearing IP access controlReset Configuration To reset the AdderView CATx IP configurationTo access the remote configuration pages Appendix 2 Configuration pages via viewerUser accounts Firmware Version Unit configurationAdmin Password Hardware VersionAdvanced unit configuration Time & date configuration IP Gateway Network configurationIP Access Control IP Network MaskTo edit/remove access control entries Setting IP access controlTo define a new IP access control entry To reorder access control entriesSerial port configuration Power control portModem port To create a new host entry Host configurationErase Host Configuration Add entry for unrecognised hostPort/host addressing using Adder Port Direct Adder Port DirectExamples For further details To get here Logging and statusTo copy and paste the log Syslog Server IP AddressPreferred encoding Appendix 3 VNC viewer connection optionsColour/Encoding Auto selectCustomise Enable all inputsDisable all inputs view-only mode InputsMisc ScalingLoad / Save Defaults ReloadDefaults Save IdentitiesAppendix 4 VNC viewer window options Appendix 5 Browser viewer options Encoding and colour levelSecurity Want to know more? Appendix 6 Addresses, masks and portsIP addresses Net masksNet masks the binary explanation 154Address ranges Calculating the mask for IP access controlSingle locations All locationsPorts Security issues with portsAppendix 7 Cable and connector specifications Power switch to power switch daisy chain cableRS232 serial flash upgrade cable Multi-head synchronisation cable Appendix 8 Hotkey sequence codes Permissible key pressesCreating macro sequences Appendix 9 Supported video modes Warranty Safety informationGeneral Public License Linux End user licence agreement Canadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United States111 Index 113 114