AMX MAX-CSE, MAX-CSD10 manual Pod, Pof, Pon

Page 108

NetLinx Programming

IR/Serial Send_Commands (Cont.)

Command

Description

 

 

POD

Channel 255 changes are enabled. This command is used in conjunction with

Disable previously active

the I/O Link command.

Syntax:

'PON' (power on) or 'POF'

(power off) command

SEND_COMMAND <DEV>,"'POD'"

settings.

Example:

 

 

SEND_COMMAND IR_1,"'POD"

 

Disables the 'PON' and 'POF' command settings on the IR_1 device.

 

 

POF

If at any time the IR sensor input reads that the device is ON (such as if

Turn Off a device connected

someone turned it on manually at the front panel), IR function 28 (if available)

or IR function 9 is automatically generated in an attempt to turn the device back

to an IR port based on the

OFF. If three attempts fail, the IR port will continue executing commands in the

status of the corresponding

buffer.

I/O Link input.

If there are no commands in the buffer, the IR port will continue executing

 

 

commands in the buffer and trying to turn the device OFF until a 'PON' or 'POD'

 

command is received. If the IR port fails to turn the device OFF, a PUSH and

 

RELEASE is made on channel 254 to indicate a power failure error. You can

 

only use the 'PON' and 'POF' commands when an IR device has a linked

 

I/O channel. Channel 255 changes are disabled after receipt of this command.

 

You can only use the 'PON' and 'POF' commands when an IR device has a

 

linked I/O channel.

 

Syntax:

 

SEND_COMMAND <DEV>,"'POF'"

 

Example:

 

SEND_COMMAND IR_1,"'POF'"

 

Sends power down IR commands 28 (if present) or 9 to the IR_1 device.

 

 

PON

If at any time the IR sensor input reads that the device is OFF (such as if one

Turn On a device connected

turned it off manually at the front panel), IR function 27 (if available) or IR

function 9 is automatically generated in an attempt to turn the device back ON.

to an IR port based on the

If three attempts fail, the IR port will continue executing commands in the buffer

status of the corresponding

and trying to turn the device On.

I/O Link input.

If there are no commands in the buffer, the IR port will continue trying to turn

 

 

the device ON until a 'POF' or 'POD' command is received. If the IR port fails to

 

turn the device ON, a PUSH and RELEASE is made on channel 254 to indicate

 

a power failure error.

 

You can only use the 'PON' and 'POF' commands when an IR device has a

 

linked I/O channel. Channel 255 changes are disabled after receipt of this

 

command.

 

Syntax:

 

SEND_COMMAND <DEV>,"'PON'"

 

Example:

 

SEND_COMMAND IR_1,"'PON'"

 

Sends power up IR commands 27 or 9 to the IR_1 port.

 

 

102

MAX-CSE/MAX-CSD10 Operation/Reference Guide

Image 108
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Displaying Stream Content Page MAX Encoder Features MAX-CSE Video EncoderOverview MAX-CSE Product Specifications MAX-CSE SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 Product Specifications MAX Decoder FeaturesMAX-CSD10 Video Decoder MAX-CSD10 FG2178-72MAX-CSD10 FG2178-72 Specifications AACMAX-CSD10 Specifications Composite OUTPage MAX-CSE and MAX-CSD10 Installation MAX-CSE and MAX-CSD10 Connections and WiringWiring Guidelines Direct Power Port Assignments and FunctionalityWiring Length Guidelines Preparing Captive WiresWiring a Power Connection Wiring Guidelines Indirect Power via PoEPoE Special Wiring Instructions MAX-CSEWiring the MAX-CSE Connectors and Cables VDC power SupplyEthernet/RJ-45 Port Connections and Wiring Ethernet RJ-45 Pinouts and SignalsSignals Connection Pairing Color MICPower over Ethernet PoE Wiring DB9 Device Port Connections and WiringEthernet LEDs IR/Serial Port Connections and Wiring Input/Output I/O Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications Wiring the MAX-CSD10 Connectors and Cables Port Wiring SpecificationsPin Signal Function Installing Into an Equipment Rack Page Default Security Configuration MAX-CSE Web InterfaceSecurity Terms Security TermsDefault Security Configuration case-sensitive Administrator accountCommunicating with the Unit via the Browser-Based UI MAX-CSE User Interface Overview and Features User Interface FeaturesFeature Description Navigation Bar Browser-based UI Application OverviewAdministration Page Features Feature DescriptionStream Status Administration AdministrationFeature Description Resources Example Computer CourseChanging the Program Description ModeUpload Firmware Click Upload a File Click Reboot done. Upload a File Upgrading New FirmwareStream Profiles Stream ProfilesStream Profiles Page Features Feature Description Encoder ProfileVideo 30fps for Ntsc and 352x288 @ 24 fps for PAL AudioSVCD, MP3 StreamSAP Settings Obtaining the IP information for a target ModeroEncoder Profiles and Parameters VCRSet-up Changing the Encoder ProfileChanging Video and Audio Settings Set up Page FeaturesFeature Description Video NetLinx Settings NetLinx SettingsNetLinx Settings Page Features Feature Description NetLinx MasterChanging the NetLinx Master Connection IP Settings IP SettingsChanging the IP Settings IP Settings Page FeaturesFeature Description IP Address DNS AddressUser Page Features Feature Description UserUser Changing User Settings MAX-CSD10 User Interface Overview and Features Feature Description Browser Address fieldMAX-CSD10 Web Interface Navigation frameFeature Description Stream Status frame LogoffActive Page frame Communicating with the Unit via the Browser-based UI Updating FirmwareStream Selector Page Features Stream SelectorStream Set-Up Page Features Stream Set-upChanging the Stream Configuration Setting up an SAP Stream ConfigurationSetting up an Rtsp Stream Configuration Setting up a Manual Stream Configuration Stream Configuration Page Manual ModeAudio/Video Page Features NetLinx Page FeaturesAudio/Video NetLinxSelects whether the IP access is dynamic or static To change the User Login Settings User Page DetailsConfiguring Communication Reading the Front Panel LCDConfiguring the MAX Communication Parameters Obtaining the Unit’s Initial Dhcp AddressSave login profile selection box Configuring Communication Communicating with the Target Master via an IP NetLinx Studio NetLinx StudioConfiguring Communication Associating the MAX Unit to a Target Master Associating a MAX-CSE to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX’s Device Number Associating a MAX-CSD10 Unit to a Target MasterChanging the MAX-CSE Device Number via the UI Changing the MAX-CSE Device Number via StudioUsing the ID Button to Change the MAX-CSE’s Device Value Recommended NetLinx Device NumbersChanging the MAX-CSD10 Device Number via the UI Page Configuration and Firmware Update Before You BeginMAX vs. NetLinx Master Functional Overlap Verifying the MAX’s Current Version of Firmware via the UIUpgrading MAX Firmware Verifying the MAX’s Current Version of Firmware via StudioUpgrading MAX-CSE Firmware via the UI Upgrading MAX-CSD10 Firmware via the UI Upgrading the MAX’s Firmware via NetLinx StudioClick Close once the download process is complete Displaying Stream Content Requirements for Receiving Streamed ContentSetting up a Modero Panel to Receive and Display a Stream Obtaining the IP Address of the Target PanelConfiguring the MAX-CSE for communication System SettingsStream Profiles Displaying Stream Content Configuring the MAX-CSE Audio/Video Inputs V SetupSetting up a streaming page within TPDesign4 Button Properties tabRtpmpeg#//IP Address of MAX-CSETarget Video Port Video Adjustment page showing default values Establishing the Final Connection Between the Two UnitsSetting up a Computer to Receive and Display a Stream Configure the MAX-CSE for Communication to a ComputerObtaining the IP Address of the Target Computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component NetLinx Programming DevicePortSystem DPSPort Assignments Port/DescriptionMAX-CSE Streaming Commands Port MAX-CSE Streaming SendCommandsCommand Description GET AsourceGET SAP IP Mode GET FormatGET Gain GET SAPGET Session Info GET Session ListGET Stream Status GET URL GET VideoGET Video Port Status GET Vsource PlaySET Asource SET AudioSET SAP IP Mode SET FormatSET Gain SET SAPSendcommand ENCODER,SET Video MPEG2 D1 6000 CBR SET URLSET Video Sendcommand ENCODER,SET Vsource Svid Sendcommand DEV,STOPSendcommand ENCODER,STOP SET VsourceMAX-CSD10 Streaming Commands Port MAX-CSD10 Streaming SendCommandsGET Control Mode GET Rtsp Server GET Session Change GET Session CursorSendcommand DEV,GET Session List Sendcommand DECODER,GET Session ListSendcommand DEV,GET Stream Status Sendcommand DECODER,GET Stream StatusSET Control Mode Sendcommand DECODER,SET SAP IP Mode ALT Sendcommand DECODER,SET SAP IP ALTSendcommand DECODER,SET Session Cursor SET Rtsp ServerSendcommand DECODER,SET Video MPEG2 D1 Sendcommand DECODER,START Rtsp ServerStart Rtsp Server RS-232/422/485 SendCommands Port RS-232/422/485 SendCommandsGET Baud HsoffHson RxclrSET Baud Tset BaudTxclr XoffRS232/422/485 Ports Channels RS-232/422/485 SendString Escape Sequences PortRS232/422/485 Ports Channels RS-232/422/485 SendString Escape SequencesCommand Description 27,19,time IR / Serial Ports ChannelsIR / Serial Ports Channels 27,20,0IR/Serial Port Port 3 Commands IR/Serial SendCommandsCaroff CaronGET Mode CtofCton IroffPOD POFPON Ptof PtonSET IO Link SET Mode Sendcommand IR1,SET Mode IRSendcommand IR1, SP,25 Short cable length 10 feetSendcommand DEV,XCHM extended channel mode Sendcommand IR1,XCHMSendcommand IR1,XCH XchmPort Commands Port Send CommandsIR RX Port Channels Port GET InputLCD Commands Port BacklightBACKLIGHT-0 BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 109 It’s Your World Take Control
Related manuals
Manual 2 pages 30.49 Kb Manual 110 pages 20.97 Kb Manual 2 pages 62.62 Kb

MAX-CSD10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.