AMX MAX-CSE, MAX-CSD10 manual To change the User Login Settings, User Page Details

Page 56

MAX-CSD10 Web Interface

To make changes to the IP Settings page:

1.From the IP Settings page and in the IP Address section, select whether the IP will be dynamic or static.

2.If you selected the IP to be static, change the information in the IP Address field, if necessary.

3.If you selected the IP to be static, change the information in the Subnet Mask field, if necessary

4.Change the information in the Gateway field, if necessary.

5.In the DNS Address section, change the information in the Domain Suffix field, if necessary.

6.Change the information in the Primary DNS and Secondary DNS fields, if necessary.

7.To reboot the system after a change, click the Reboot button. Click OK to confirm the reboot or Cancel to return to the IP Settings page.

8.To save changes without rebooting the system, click Accept. If you wish to keep the original settings, click Cancel.

User Page

The User page (FIG. 30) allows the user to make remote changes to passwords.

FIG. 30 User Page

User Page Details

• Username

The administrator’s registered username.

 

 

• New Password

The new password to be used with the MAX-CSD10.

 

 

Re-type Password

Confirmation of the new password.

 

 

To change the User Login Settings:

1.From the User page, enter your username in the Username field.

2.Enter your new password.

3.Re-enter the password to confirm that this is the correct one.

4.To save your changes, click the Accept button. To keep the current password, click Cancel.

50

MAX-CSE/MAX-CSD10 Operation/Reference Guide

Image 56
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Displaying Stream Content Page Overview MAX Encoder FeaturesMAX-CSE Video Encoder MAX-CSE Product Specifications MAX-CSE SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 Product Specifications MAX Decoder FeaturesMAX-CSD10 Video Decoder MAX-CSD10 FG2178-72MAX-CSD10 FG2178-72 Specifications AACMAX-CSD10 Specifications Composite OUTPage MAX-CSE and MAX-CSD10 Installation MAX-CSE and MAX-CSD10 Connections and WiringWiring Guidelines Direct Power Port Assignments and FunctionalityWiring Length Guidelines Preparing Captive WiresWiring a Power Connection Wiring Guidelines Indirect Power via PoEPoE Special Wiring Instructions MAX-CSEWiring the MAX-CSE Connectors and Cables VDC power SupplyEthernet/RJ-45 Port Connections and Wiring Ethernet RJ-45 Pinouts and SignalsSignals Connection Pairing Color MICEthernet LEDs Power over Ethernet PoE WiringDB9 Device Port Connections and Wiring RS-232/422/485 Device Port Wiring Specifications IR/Serial Port Connections and WiringInput/Output I/O Port Connections and Wiring Pin Signal Function Wiring the MAX-CSD10 Connectors and CablesPort Wiring Specifications Installing Into an Equipment Rack Page Default Security Configuration MAX-CSE Web InterfaceSecurity Terms Security TermsCommunicating with the Unit via the Browser-Based UI Default Security Configuration case-sensitiveAdministrator account MAX-CSE User Interface Overview and Features User Interface FeaturesFeature Description Navigation Bar Browser-based UI Application OverviewStream Status Administration Page FeaturesFeature Description Administration AdministrationFeature Description Resources Example Computer CourseUpload Firmware Changing the Program DescriptionMode Click Upload a File Click Reboot done. Upload a File Upgrading New FirmwareStream Profiles Stream ProfilesVideo Stream Profiles Page FeaturesFeature Description Encoder Profile 30fps for Ntsc and 352x288 @ 24 fps for PAL AudioSVCD, MP3 StreamSAP Settings Obtaining the IP information for a target ModeroEncoder Profiles and Parameters VCRSet-up Changing the Encoder ProfileFeature Description Video Changing Video and Audio SettingsSet up Page Features NetLinx Settings NetLinx SettingsNetLinx Settings Page Features Feature Description NetLinx MasterChanging the NetLinx Master Connection IP Settings IP SettingsChanging the IP Settings IP Settings Page FeaturesFeature Description IP Address DNS AddressUser User Page FeaturesFeature Description User Changing User Settings MAX-CSD10 User Interface Overview and Features Feature Description Browser Address fieldMAX-CSD10 Web Interface Navigation frameActive Page frame Feature Description Stream Status frameLogoff Communicating with the Unit via the Browser-based UI Updating FirmwareStream Selector Page Features Stream SelectorStream Set-Up Page Features Stream Set-upSetting up an Rtsp Stream Configuration Changing the Stream ConfigurationSetting up an SAP Stream Configuration Setting up a Manual Stream Configuration Stream Configuration Page Manual ModeAudio/Video Page Features NetLinx Page FeaturesAudio/Video NetLinxSelects whether the IP access is dynamic or static To change the User Login Settings User Page DetailsConfiguring Communication Reading the Front Panel LCDConfiguring the MAX Communication Parameters Obtaining the Unit’s Initial Dhcp AddressSave login profile selection box Configuring Communication Communicating with the Target Master via an IP NetLinx Studio NetLinx StudioConfiguring Communication Associating the MAX Unit to a Target Master Associating a MAX-CSE to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX’s Device Number Associating a MAX-CSD10 Unit to a Target MasterChanging the MAX-CSE Device Number via the UI Changing the MAX-CSE Device Number via StudioUsing the ID Button to Change the MAX-CSE’s Device Value Recommended NetLinx Device NumbersChanging the MAX-CSD10 Device Number via the UI Page Configuration and Firmware Update Before You BeginMAX vs. NetLinx Master Functional Overlap Verifying the MAX’s Current Version of Firmware via the UIUpgrading MAX-CSE Firmware via the UI Upgrading MAX FirmwareVerifying the MAX’s Current Version of Firmware via Studio Upgrading MAX-CSD10 Firmware via the UI Upgrading the MAX’s Firmware via NetLinx StudioClick Close once the download process is complete Displaying Stream Content Requirements for Receiving Streamed ContentSetting up a Modero Panel to Receive and Display a Stream Obtaining the IP Address of the Target PanelConfiguring the MAX-CSE for communication System SettingsStream Profiles Displaying Stream Content Configuring the MAX-CSE Audio/Video Inputs V SetupSetting up a streaming page within TPDesign4 Button Properties tabRtpmpeg#//IP Address of MAX-CSETarget Video Port Video Adjustment page showing default values Establishing the Final Connection Between the Two UnitsObtaining the IP Address of the Target Computer Setting up a Computer to Receive and Display a StreamConfigure the MAX-CSE for Communication to a Computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component NetLinx Programming DevicePortSystem DPSPort Assignments Port/DescriptionMAX-CSE Streaming Commands Port MAX-CSE Streaming SendCommandsCommand Description GET AsourceGET SAP IP Mode GET FormatGET Gain GET SAPGET Stream Status GET Session InfoGET Session List GET Video Port Status GET URLGET Video GET Vsource PlaySET Asource SET AudioSET SAP IP Mode SET FormatSET Gain SET SAPSET Video Sendcommand ENCODER,SET Video MPEG2 D1 6000 CBRSET URL Sendcommand ENCODER,SET Vsource Svid Sendcommand DEV,STOPSendcommand ENCODER,STOP SET VsourceGET Control Mode MAX-CSD10 Streaming Commands PortMAX-CSD10 Streaming SendCommands GET Rtsp Server GET Session Change GET Session CursorSendcommand DEV,GET Session List Sendcommand DECODER,GET Session ListSendcommand DEV,GET Stream Status Sendcommand DECODER,GET Stream StatusSET Control Mode Sendcommand DECODER,SET SAP IP Mode ALT Sendcommand DECODER,SET SAP IP ALTSendcommand DECODER,SET Session Cursor SET Rtsp ServerStart Rtsp Server Sendcommand DECODER,SET Video MPEG2 D1Sendcommand DECODER,START Rtsp Server RS-232/422/485 SendCommands Port RS-232/422/485 SendCommandsGET Baud HsoffHson RxclrSET Baud Tset BaudTxclr XoffRS232/422/485 Ports Channels RS-232/422/485 SendString Escape Sequences PortRS232/422/485 Ports Channels RS-232/422/485 SendString Escape SequencesCommand Description 27,19,time IR / Serial Ports ChannelsIR / Serial Ports Channels 27,20,0IR/Serial Port Port 3 Commands IR/Serial SendCommandsCaroff CaronGET Mode CtofCton IroffPON PODPOF SET IO Link PtofPton SET Mode Sendcommand IR1,SET Mode IRSendcommand IR1, SP,25 Short cable length 10 feetSendcommand DEV,XCHM extended channel mode Sendcommand IR1,XCHMSendcommand IR1,XCH XchmPort Commands Port Send CommandsIR RX Port Channels Port GET InputLCD Commands Port BacklightBACKLIGHT-0 BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 109 It’s Your World Take Control
Related manuals
Manual 2 pages 30.49 Kb Manual 110 pages 20.97 Kb Manual 2 pages 62.62 Kb

MAX-CSD10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.