AMX MAX-CSE Short cable length 10 feet, Sendcommand IR1,SET Mode IR, Sendcommand IR1, SP,25

Page 110

NetLinx Programming

IR/Serial Send_Commands (Cont.)

Command

Description

 

 

SET MODE

Sets an IR port to either IR, Serial, or Data mode.

Set the IR/Serial ports for IR

Note: IR DATA Mode works best when using both a lower baud rate and a

or Serial-controlled devices

connected to a CardFrame or

short cable length (< 10 feet).

NetModule.

Syntax:

 

SEND_COMMAND <DEV>, 'SET MODE <mode>'"

 

Variable:

 

mode = IR, SERIAL, or DATA.

 

Example:

 

SEND_COMMAND IR_1,"'SET MODE IR'"

 

Sets the IR_1 port to IR mode for IR control.

 

 

SP

You can use the 'CTON' to set pulse lengths and the 'CTOF' for time Off between

Generate a single IR pulse.

pulses.

Syntax:

 

 

SEND_COMMAND <DEV>,"'SP',<code>"

 

Variable:

 

code = IR code value 1 - 252 (253-255 reserved).

 

Example:

 

SEND_COMMAND IR_1, "'SP',25"

 

Pulses IR code 25 on IR_1 device.

 

 

XCH

Syntax:

Transmit the selected chan-

SEND_COMMAND <DEV>,"'XCH <channel>'"

nel IR codes in the format/

Variable:

pattern set by the 'XCHM'

channel = 0 - 999.

send

Example:

command.

For detailed usage examples, refer to the 'XCHM' command.

 

 

 

104

MAX-CSE/MAX-CSD10 Operation/Reference Guide

Image 110
Contents MAX-CSE/MAX-CSD10 AMX Limited Warranty and Disclaimer Table of Contents MAX-CSD10 Web Interface Displaying Stream Content Page Overview MAX Encoder FeaturesMAX-CSE Video Encoder MAX-CSE Product Specifications MAX-CSE SpecificationsWhile in IR mode Sensing for IR ports MAX-CSD10 Video Decoder MAX-CSD10 Product SpecificationsMAX Decoder Features MAX-CSD10 FG2178-72MAX-CSD10 FG2178-72 Specifications AACMAX-CSD10 Specifications Composite OUTPage Wiring Guidelines Direct Power MAX-CSE and MAX-CSD10 InstallationMAX-CSE and MAX-CSD10 Connections and Wiring Port Assignments and FunctionalityWiring a Power Connection Wiring Length GuidelinesPreparing Captive Wires Wiring Guidelines Indirect Power via PoEPoE Special Wiring Instructions MAX-CSEWiring the MAX-CSE Connectors and Cables VDC power SupplySignals Connection Pairing Color Ethernet/RJ-45 Port Connections and WiringEthernet RJ-45 Pinouts and Signals MICEthernet LEDs Power over Ethernet PoE WiringDB9 Device Port Connections and Wiring RS-232/422/485 Device Port Wiring Specifications IR/Serial Port Connections and WiringInput/Output I/O Port Connections and Wiring Pin Signal Function Wiring the MAX-CSD10 Connectors and CablesPort Wiring Specifications Installing Into an Equipment Rack Page Security Terms Default Security ConfigurationMAX-CSE Web Interface Security TermsCommunicating with the Unit via the Browser-Based UI Default Security Configuration case-sensitiveAdministrator account Feature Description Navigation Bar MAX-CSE User Interface Overview and FeaturesUser Interface Features Browser-based UI Application OverviewStream Status Administration Page FeaturesFeature Description Feature Description Resources AdministrationAdministration Example Computer CourseUpload Firmware Changing the Program DescriptionMode Click Upload a File Click Reboot done. Upload a File Upgrading New FirmwareStream Profiles Stream ProfilesVideo Stream Profiles Page FeaturesFeature Description Encoder Profile 30fps for Ntsc and 352x288 @ 24 fps for PAL AudioSVCD, MP3 StreamSAP Settings Obtaining the IP information for a target ModeroEncoder Profiles and Parameters VCRSet-up Changing the Encoder ProfileFeature Description Video Changing Video and Audio SettingsSet up Page Features NetLinx Settings NetLinx SettingsNetLinx Settings Page Features Feature Description NetLinx MasterChanging the NetLinx Master Connection IP Settings IP SettingsFeature Description IP Address Changing the IP SettingsIP Settings Page Features DNS AddressUser User Page FeaturesFeature Description User Changing User Settings MAX-CSD10 Web Interface MAX-CSD10 User Interface Overview and FeaturesFeature Description Browser Address field Navigation frameActive Page frame Feature Description Stream Status frameLogoff Communicating with the Unit via the Browser-based UI Updating FirmwareStream Selector Page Features Stream SelectorStream Set-Up Page Features Stream Set-upSetting up an Rtsp Stream Configuration Changing the Stream ConfigurationSetting up an SAP Stream Configuration Setting up a Manual Stream Configuration Stream Configuration Page Manual ModeAudio/Video Audio/Video Page FeaturesNetLinx Page Features NetLinxSelects whether the IP access is dynamic or static To change the User Login Settings User Page DetailsConfiguring Communication Reading the Front Panel LCDConfiguring the MAX Communication Parameters Obtaining the Unit’s Initial Dhcp AddressSave login profile selection box Configuring Communication Communicating with the Target Master via an IP NetLinx Studio NetLinx StudioConfiguring Communication Associating the MAX Unit to a Target Master Associating a MAX-CSE to a Target MasterStudio Online Tree tab showing the communicating MAX unit Changing the MAX-CSE Device Number via the UI Changing the MAX’s Device NumberAssociating a MAX-CSD10 Unit to a Target Master Changing the MAX-CSE Device Number via StudioUsing the ID Button to Change the MAX-CSE’s Device Value Recommended NetLinx Device NumbersChanging the MAX-CSD10 Device Number via the UI Page MAX vs. NetLinx Master Functional Overlap Configuration and Firmware UpdateBefore You Begin Verifying the MAX’s Current Version of Firmware via the UIUpgrading MAX-CSE Firmware via the UI Upgrading MAX FirmwareVerifying the MAX’s Current Version of Firmware via Studio Upgrading MAX-CSD10 Firmware via the UI Upgrading the MAX’s Firmware via NetLinx StudioClick Close once the download process is complete Displaying Stream Content Requirements for Receiving Streamed ContentSetting up a Modero Panel to Receive and Display a Stream Obtaining the IP Address of the Target PanelConfiguring the MAX-CSE for communication System SettingsStream Profiles Displaying Stream Content Configuring the MAX-CSE Audio/Video Inputs V SetupSetting up a streaming page within TPDesign4 Button Properties tabRtpmpeg#//IP Address of MAX-CSETarget Video Port Video Adjustment page showing default values Establishing the Final Connection Between the Two UnitsObtaining the IP Address of the Target Computer Setting up a Computer to Receive and Display a StreamConfigure the MAX-CSE for Communication to a Computer Displaying Stream Content RTP Video Stream Component RTP Audio Stream Component Port Assignments NetLinx ProgrammingDevicePortSystem DPS Port/DescriptionCommand Description MAX-CSE Streaming Commands PortMAX-CSE Streaming SendCommands GET AsourceGET Gain GET SAP IP ModeGET Format GET SAPGET Stream Status GET Session InfoGET Session List GET Video Port Status GET URLGET Video SET Asource GET VsourcePlay SET AudioSET Gain SET SAP IP ModeSET Format SET SAPSET Video Sendcommand ENCODER,SET Video MPEG2 D1 6000 CBRSET URL Sendcommand ENCODER,STOP Sendcommand ENCODER,SET Vsource SvidSendcommand DEV,STOP SET VsourceGET Control Mode MAX-CSD10 Streaming Commands PortMAX-CSD10 Streaming SendCommands GET Rtsp Server GET Session Change GET Session CursorSendcommand DEV,GET Stream Status Sendcommand DEV,GET Session ListSendcommand DECODER,GET Session List Sendcommand DECODER,GET Stream StatusSET Control Mode Sendcommand DECODER,SET Session Cursor Sendcommand DECODER,SET SAP IP Mode ALTSendcommand DECODER,SET SAP IP ALT SET Rtsp ServerStart Rtsp Server Sendcommand DECODER,SET Video MPEG2 D1Sendcommand DECODER,START Rtsp Server RS-232/422/485 SendCommands Port RS-232/422/485 SendCommandsHson GET BaudHsoff RxclrTxclr SET BaudTset Baud XoffRS232/422/485 Ports Channels RS232/422/485 Ports ChannelsRS-232/422/485 SendString Escape Sequences Port RS-232/422/485 SendString Escape SequencesIR / Serial Ports Channels Command Description 27,19,timeIR / Serial Ports Channels 27,20,0Caroff IR/Serial Port Port 3 CommandsIR/Serial SendCommands CaronCton GET ModeCtof IroffPON PODPOF SET IO Link PtofPton Sendcommand IR1, SP,25 SET ModeSendcommand IR1,SET Mode IR Short cable length 10 feetSendcommand IR1,XCH Sendcommand DEV,XCHM extended channel modeSendcommand IR1,XCHM XchmIR RX Port Channels Port Port Commands PortSend Commands GET InputBACKLIGHT-0 LCD Commands PortBacklight BACKLIGHT-50Page Programming MAX-CSE/MAX-CSD10 Operation/Reference Guide 109 It’s Your World Take Control
Related manuals
Manual 2 pages 30.49 Kb Manual 110 pages 20.97 Kb Manual 2 pages 62.62 Kb

MAX-CSD10, MAX-CSE specifications

The AMX MAX-CSE and MAX-CSD 10 are advanced multimedia presentation systems designed to enhance communication and collaboration in various professional environments. These devices are tailored for modern conference rooms, educational institutions, and corporate settings, providing seamless integration of audio-visual technology to facilitate effective presentations and meetings.

One of the standout features of the MAX-CSE and MAX-CSD 10 is their sophisticated audio and video processing capabilities. The MAX-CSE serves as a central management hub, supporting high-definition video outputs and multiple input sources, including HDMI, VGA, and wireless connectivity options. This versatility ensures that users can connect a wide array of devices—laptops, tablets, and smartphones—without hassle and quickly switch between them during presentations.

The MAX-CSD 10 complements the MAX-CSE as a dedicated audio unit equipped with powerful amplification and precise tuning. It delivers clear and balanced sound, even in larger rooms, ensuring that every participant can engage fully, regardless of their location in the space. With features like echo cancellation and noise reduction technology, the MAX-CSD 10 enhances voice clarity, making it ideal for video conferencing and webinars.

An important characteristic of the AMX MAX series is their user-friendly interface. The systems are designed for intuitive operation, enabling users to control various settings with ease, whether they are tech-savvy or not. The touch panel interface can be customized to meet specific needs, allowing quick access to essential functions such as lighting, video routing, and audio control.

In terms of connectivity, both systems are equipped with robust network capability, allowing integration with existing IT infrastructure. This feature ensures that users can manage and control the systems remotely through a web interface or compatible applications, enhancing productivity and easing the overall user experience.

Robust security measures are also a significant aspect of the AMX MAX-CSE and MAX-CSD 10 systems. They are designed with advanced encryption and user authentication protocols, ensuring that sensitive data remains protected during presentations and meetings.

In conclusion, the AMX MAX-CSE and MAX-CSD 10 multimedia presentation systems stand out in the market due to their superior audio and video quality, user-friendly features, and extensive connectivity options. They are ideal solutions for professionals seeking to leverage technology for more productive and engaging communication.