Lathem 6000E manual Ottom 6IEW, Screw, Connection Specifications for External Contact

Page 31

6. CONNECTING EXTERNAL TIME SIGNAL

Follow the steps below to connect an external time signal device.

"OTTOM 6IEW

Screw

Cover Plate

1Unscrew the screw fixed on the bottom of the unit to remove the cover plate.

3 Insert wires into Terminals while pushing upper part of Terminal Block with screwdriver, then tighten both screws of cable clamp.

Connection Specifications for External Contact

ss#ONTACTNOUTPUTT/NEOCIRCUIT DRY CONTACT ss#ONTACTNCAPACITY ! A 6$#C ! T 6!#

2Feed wires through clamp. Do not tighten clamp screws.

Channel

4Fold down Cover Plate and secure

with screw. Route Power and Bell wires through Channel in base of clock.

Maximum of 8 bells/horns (typical)

#LOC O2ELAY

!MPS -AX

8

6!#

ENGLISH

28

Image 31
Contents Lathem Time Corporation Lathem Time Corporation Table of Contents Signs PrecautionsDaily Care Features Location of Controls AccessoriesDaylight saving time indication Day of the week indication Panel open button Installing Ribbon CassetteEnvironmental Conditions Mounting Unit on WallDaily Operations SettingKey hole Panel house Display SettingPreparation for setting To prepare for setting Unlock the unit. While holding downStays LIT UP Setting Pay Ending and Card / Print LanguageMonthly Closing 2EMOVE the Panel COVERToday is printed on the second line from the top Weekly ClosingPrint language Day of the week Bi-weekly closing Bi-Weekly ClosingEnglish Select 12/24 Hour formatDATE/TIME English To cause digits to flash, and then press or Setting the Day Advance Time$A Aadvancedtime Press orDaylight saving time function Setting the Daylight Saving Time D.S.TTo Select Theh Month and DA3TARTADATE OFD$34 1/60 3ETTINGTTHENSTARTTDATEEnd date How to Cancel D.S.T. SettingsEXT DAY Setting the Time Table ProgramTime to be set External time signal Column Disabled no setting EnabledFollow the steps to set time table programs Print color 00 Black 01 RedLower left of the display Represents print in black Press Print in redTo set P-01 shown in the table Above Print color With P-01 flashing, press OnceErase under MO MinuteErase under TU Staying lit up Erase under MO SAPrint in black1/100 External 1/60 time signal 1/100Make the bars Under MO-SA lit upIndication at To check program settingsTo modify program settings To erase program settingsSEC DS Press Select to cause EXT. Alarm to light up84 !,!2 Resetting Maximum of 8 bells/horns typical Connection Specifications for External ContactOttom 6IEW ScrewInstalling Ni-Cd Battery optional Error No. appears TroubleshootingOther failures Connection SpecificationsExternal time signal Temperature -5˚ to + 45˚CTime Card Specifications Semi-Monthly Card Q0086 6120