Lathem 6000E manual Specifications, Connection, External time signal, Temperature -5˚ to + 45˚C

Page 34

9. SPECIFICATIONS

Clock accuracy

Monthly accuracy

15s (at ordinary temperature)

 

 

 

Year up to 2096. Automatically adjusted to leap years, 31-day

Calendar

months and months with thirty or fewer days, and the days of

 

the week.

 

Printing system

Dot matrix in black and red

 

 

Card mechanism

Automatic pull and eject, automatic judgment of face and back

 

 

Power failure

Five years of cumulative power failure hours after the date of

compensation

shipment

 

 

 

 

Print at power

Special Ni-Cd battery, 100-time printing or 24 hours (option)

failure

 

 

 

 

Time program

Switching between black and red printing, designation of the time

for outputting an external time signal, automatic column shift.

 

 

 

 

Connection of

Connection with a time blow device (No direct voltage output!)

external time signal

 

 

 

 

 

Temperature: -5˚ to + 45˚C

 

: + 23˚ to + 113˚F

Operating

Humidity: 20 to 80%RH, no condensation

environment

The unit operates normally at temperatures of 5˚C or below,

 

but the print density, reaction of the liquid crystal display, and

 

the number of prints at power failure are inferior to those at

 

normal temperature operation.

 

 

Dimensions

7.87" (w) x 10.1" (h) x 5.94" (d)

200 (w) x 257 (h) x 151 (d) mm

 

 

 

Weight

Approx. 5.5lbs 2.5kg

 

 

 

Power supply

120VAC

 

230VAC (220-240VAC)

 

 

 

 

 

120VAC 50/60Hz

0.2A

Power consumption

230VAC 50/60Hz

0.12A

220-240VAC 50/60Hz 0.12A

Machine Noise Information Ordinance 3. GSGV, January 18, 1991:

The sound pressure level at the operator position is equal to or less than 70 dB (A)

according to ISO 7779.

Maschinenlärminformationsverordnung 3. GSGV, 18.01.1991:

Der arbeitsplatzbezogene Schalldruckpegel beträgt 70 dB (A) oder weniger gemäß

ISO 7779.

31

Image 34
Contents Lathem Time Corporation Lathem Time Corporation Table of Contents Precautions SignsDaily Care Features Location of Controls AccessoriesDaylight saving time indication Day of the week indication Installing Ribbon Cassette Panel open buttonMounting Unit on Wall Environmental ConditionsSetting Daily OperationsTo prepare for setting Unlock the unit. While holding down SettingPreparation for setting Key hole Panel house Display2EMOVE the Panel COVER Setting Pay Ending and Card / Print LanguageMonthly Closing Stays LIT UPToday is printed on the second line from the top Weekly ClosingPrint language Day of the week Bi-Weekly Closing Bi-weekly closingEnglish Select 12/24 Hour formatDATE/TIME English Press or Setting the Day Advance Time$A Aadvancedtime To cause digits to flash, and then press orSetting the Daylight Saving Time D.S.T Daylight saving time function3ETTINGTTHENSTARTTDATE Month and DA3TARTADATE OFD$34 1/60 To Select ThehHow to Cancel D.S.T. Settings End dateSetting the Time Table Program EXT DAYPrint color 00 Black 01 Red External time signal Column Disabled no setting EnabledFollow the steps to set time table programs Time to be setAbove Print color With P-01 flashing, press Once Print in redTo set P-01 shown in the table Lower left of the display Represents print in black PressErase under MO MinuteErase under TU Erase under MO SA Staying lit upUnder MO-SA lit up External 1/60 time signal 1/100Make the bars Print in black1/100To erase program settings To check program settingsTo modify program settings Indication atSEC DS Press Select to cause EXT. Alarm to light up84 !,!2 Resetting Screw Connection Specifications for External ContactOttom 6IEW Maximum of 8 bells/horns typicalInstalling Ni-Cd Battery optional Error No. appears TroubleshootingOther failures Temperature -5˚ to + 45˚C SpecificationsExternal time signal ConnectionTime Card Specifications Semi-Monthly Card Q0086 6120