JVC RM-P210 manual Process Menu

Page 23

MENU OPERATION

PROCESS MENU

This menu sets the functions built into the camera.

(Some of the following items cannot be set if a local remote control unit is connected to the camera or depending on the connected camera model.)

No.

Item

 

 

Function, Operation

Available Settings

Initial Setting

 

 

 

 

 

 

 

4A

DETAIL

ON/OFF setting of the detail enhancement function.

OFF

ON

 

 

OFF : Detail enhancement is deactivated.

ON

 

 

 

ON : Detail enhancement is activated.

 

 

 

 

 

 

 

 

 

4B

DETAIL LEVEL

Adjusts the detail enhancement level.

10 to

NORMAL

 

 

Increasing the level

: Sharpens details.

NORMAL to

 

 

 

Decreasing the level

: Softens details.

-10

 

 

 

 

 

 

 

(21 steps)

 

 

 

 

 

 

 

 

4C

DETAIL V/H

Selects whether the detail enhancement is applied more strongly

10 to

NORMAL

 

 

in a horizontal or vertical direction.

NORMAL to

 

 

 

Increasing the level

: Applies detail enhancement more

-10

 

 

 

 

 

 

strongly in a H direction.

(21 steps)

 

 

 

Decreasing the level : Applies low detail enhancement in the H

 

 

 

 

 

 

 

direction.

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

This item cannot vary the detail enhancement in the V direction.

4D

DETAIL FRQ

Sets the detail enhancement frequency according to the object.

LOW

MIDDLE

 

 

LOW : Low frequency to be used when shooting a coarsely

MIDDLE

 

 

 

 

patterned object.

HIGH

 

 

 

MIDDLE : Standard frequency.

AUTO

 

 

 

HIGH : High frequency to be used when shooting a small or

 

 

 

 

 

finely patterned object.

 

 

 

 

AUTO : Automatic adjustment of the detail enhancement fre-

 

 

 

 

 

quency according to the object.

 

 

 

 

 

 

 

 

 

4E

SKIN DETAIL

ON/OFF setting of the skin tone detail function, which displays

OFF

OFF

 

 

natural, wet skin colors by reducing detail enhancement on the

ON

 

 

 

skin areas.

 

 

 

 

OFF : Skin tone detail function is deactivated.

 

 

 

 

ON : Skin tone detail function is activated.

 

 

 

 

 

 

 

 

 

4F

AUTO KNEE

ON/OFF setting whether the auto knee function is activated accord-

OFF

ON

 

 

ing to the knee point setting to be made below.

ON

 

 

 

OFF : Auto knee function is deactivated.

 

 

 

 

ON : Auto knee function is activated.

 

 

 

 

 

 

 

 

 

4G

KNEE POINT

Sets the knee point level at which the auto knee function is de-

10 to

NORMAL

 

 

activated.

NORMAL to

 

 

 

Increasing the level : The knee function is activated at a

-10

 

 

 

 

 

higher video level.

 

 

 

 

Decreasing the level : The knee function is activated at a lower

 

 

 

 

 

 

video level.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

The actual

variation in the knee point occurs step by step because

 

 

 

 

this is set as a result of the knee point setting of the camera.

 

 

 

 

 

 

 

 

 

4H

COLOR MATRIX

ON/OFF setting of whether the color matrix function.

OFF

ON

 

 

OFF : The color matrix function is deactivated.

ON

 

 

 

ON : The color matrix function improves the color reproducibility.

 

 

 

 

 

Note that noise increases with this setting.

 

 

23

Image 23
Contents RM-P210 Important Safeguards Introduction Safety PrecautionsPrecautions for Proper USE FeaturesProvided Accessories and Documents  Front panel CONTROLS, Connectors and Indicators$ White Paint button with lamp Power switch@ White W.BAL B/A/PRESET switch # White Auto button with lamp Rear panel KY-D29W ConnectionExample of Basic Connection VCRRTS unit Example of RM-P210 Connection of 2 Units Standard connection of RM-P210 Connection of 2 units Right side Camera Setup GY-DV550 camera  KY-D29/KY-D29W cameraTurning the Power on Fine adjusting the C Chrominance signal level Camera Cable Length SetupSetting the cable length Fine adjusting the Y luminance signal levelPreparation Adjustments for Genlock OperationAdjusting the H Phase Adjusting SC phaseRear panel IntercomCamera Operator Call Tally InputFunction Name Display 3-Character Display 7-Character Switching an assigned function on/offFunction Keys Checking the assigned functionsGain Adjustment Camera AdjustmentsShutter Speed Adjustment Camera lens iris can be adjusted from the RM-P210 Iris AdjustmentREF. Error Messages on White Balance AdjustmentAuto white balance adjustment Auto Setup Manual white balance adjustmentFlow of Menus Menu OperationSystem Reset 8 Exit Menu Setup MethodCable Menu Genlock MenuReading the data in a file Resetting data in a fileFile Menu Writing data in a fileProcess Menu Gamma Level ResolutionMAX GammaOperation Menu Normal Backlight LCD Mode MenuThis menu sets up the LCD display ContrastInitial values System Reset MenuStatus Setting Initial Values General Error MessagesD29 D29W KY-19 Functions Available Depending on Camera ModelsConnected Function ModelCheck the Camera Troubleshooting External Dimensions Unit mm Specifications Output Signals  Input SignalsRM-P210 Remote Control Unit