MENU OPERATION

GENLOCK MENU

This menu is used to set the camera cable length to the length actually used.

(

REF.

: “Adjustments for Genlock Operation” on page 13.)

No.

Item

Function, Operation

Available Settings

Initial Setting

 

 

 

 

 

1A

H PHASE

Adjustment of the Horizontal sync phase of genlocking.

0 to 255

128

 

 

 

 

 

1B

SC COARSE

Coarse adjustment of the color phase of genlocking.

0°, 90°,

 

 

Use a vectorscope, etc.

180°, 270°

 

 

 

 

 

 

1C

SC FINE

Fine adjustment of the color phase, which should be performed

0 to 255

128

 

 

after completing the SC COARSE adjustment.

 

 

 

 

If the subcarrier cannot be adjusted with SC FINE, restart the

 

 

 

 

adjustment from SC COARSE.

 

 

 

 

 

 

 

1Z

BACK

Return to the previous display.

 

 

 

 

 

CABLE MENU

This menu sets the camera cable length according to the actual length used.

(

REF.

: “Camera Cable Length Setup” on page 12.)

No.

Item

 

 

Function, Operation

Available Settings

Initial Setting

 

 

 

 

 

 

 

2A

LENGTH

Set according to the total length of the camera cables in use.

5M, 20M,

20M

 

 

 

 

 

50M, 100M

 

 

 

 

 

 

 

 

2B

Y CABLE EQ

Fine adjustment of the luminance signal.

-128 to

NORMAL

 

 

 

 

 

NORMAL to

 

 

 

 

 

 

127

 

 

 

 

 

 

 

 

2C

C CABLE EQ

Fine adjustment of the chrominace component.

-128 to

NORMAL

 

 

 

 

 

NORMAL to

 

 

 

 

NOTE

 

 

 

 

 

 

127

 

 

 

This adjustment causes the phase to be altered. Be sure to

 

 

 

adjust SC FINE after this adjustment.

 

 

2Z

BACK

Return to the previous display.

21

Image 21
Contents RM-P210 Important Safeguards Introduction Safety PrecautionsFeatures Provided Accessories and DocumentsPrecautions for Proper USE  Front panel CONTROLS, Connectors and Indicators@ White W.BAL B/A/PRESET switch Power switch# White Auto button with lamp $ White Paint button with lamp Rear panel Example of Basic Connection ConnectionVCR KY-D29WExample of RM-P210 Connection of 2 Units  Standard connection of RM-P210 Connection of 2 unitsRTS unit  GY-DV550 camera Camera Setup KY-D29/KY-D29W camera Right sideTurning the Power on Setting the cable length Camera Cable Length SetupFine adjusting the Y luminance signal level Fine adjusting the C Chrominance signal levelAdjusting the H Phase Adjustments for Genlock OperationAdjusting SC phase PreparationCamera Operator Call IntercomTally Input Rear panelFunction Keys Switching an assigned function on/offChecking the assigned functions Function Name Display 3-Character Display 7-CharacterCamera Adjustments Shutter Speed AdjustmentGain Adjustment Camera lens iris can be adjusted from the RM-P210 Iris Adjustment Auto white balance adjustment Auto Setup White Balance Adjustment Manual white balance adjustment REF. Error Messages onFlow of Menus Menu OperationSystem Reset 8 Exit Menu Setup MethodCable Menu Genlock MenuFile Menu Resetting data in a fileWriting data in a file Reading the data in a fileProcess Menu MAX ResolutionGamma Gamma LevelOperation Menu This menu sets up the LCD display LCD Mode MenuContrast Normal BacklightSystem Reset Menu Status Setting Initial ValuesInitial values General Error MessagesConnected Functions Available Depending on Camera ModelsFunction Model D29 D29W KY-19Check the Camera Troubleshooting Output Signals Specifications Input Signals  External Dimensions Unit mmRM-P210 Remote Control Unit