Extron electronic DVS 406 D, DVS 406 A Using the command/response tables, Symbol definitions

Page 37

Using the command/response tables

The command/response tables on the next page list valid command ASCII codes, the scaler’s responses to the host, and a description of the command’s function or the results of executing the command. Except when setting audio gain/ attenuation, detail, and sharpness, upper and lower case characters may be used interchangeably in the command field.

The ASCII to HEX conversion table at left is for use with the command/response tables.

ASCII to HEX Conversion Table

ASCII to Hex conversion table

The command/response tables use symbols (defined below) to represent variables.

Symbol definitions

= CR/LF (carriage return/line feed) (hex 0D 0A)

= Space

Esc

=

Escape key

 

 

X1

=

Specific input number (1 through 6)

 

 

 

 

1

= input 1, 2 = input 2, and so forth

X2

=

0 = off, 1 = on

 

 

X4

=

Video signal type (1 through 8)

 

 

 

 

1

= RGB pass-through

 

 

 

 

 

2

= YUV pass-through

 

 

 

 

 

3

= RGBcS

 

 

 

 

 

 

4 = YUVi, interlaced

 

 

 

 

 

 

5 = YUVp, progressive

 

 

 

 

 

6 = composite video

 

 

 

 

 

 

7

=

S-video

 

 

 

 

 

 

8

=

SDI (serial digital interface)

X6

=

Audio gain (0 through 9) in 1 dB steps

X7

=

Audio attenuation (1 through 15) in 1 dB steps

X8

=

Controller firmware version (listed to

 

 

 

 

two decimal places e.g.: x.xx)

X9

=

Numeric value (-15 through +9) in dB

 

 

=

Picture adjustment range (0 through 255)

X10

 

 

=

Scaler resolution

 

 

X11

 

 

 

 

 

 

1

 

= 640x480

9

= 1365x1024

 

 

 

2

 

= 800x600

10

= 1400x1050

 

 

 

3

 

= 848x480

11

= 480p

 

 

 

4

 

= 852x480

12

= 576p

 

 

 

5

 

= 1024x768

13

= 720p

 

 

 

6

 

= 1280x768

14

= 1080p

 

 

 

7

 

= 1280x1024

15

= 1080i

 

 

 

8

 

= 1360x765

16

= Lock to input 1*

X12 = Detected input signal standard (0 through 4)

0 = none

1 = NTSC 3.58

2 = PAL

3 = NTSC 4.43

4 = SECAM

= not applicable (occurs when the input is set for RGB, YUV, or progressive YUV)

X13 = Detail level (0 through 63)

X16 = Executive mode status (0 through 2)

0 = disabled (executive mode off, normal mode on)

1 = enabled, image adjustments are locked

X17 = Blanking adjustment range (0 through 127 lines)

X18 = Sharpness level (0 through 63)

X19 = Input configuration preset (1 through 3)

X20 = Scaler refresh rate

1= 50 Hz

2= 56 Hz (1280x768 only)

3= 60 Hz

4= 75 Hz

5= AFL* (50 Hz for PAL or 59.94 Hz for NTSC)

6= True rate (72 Hz for NTSC or 100 Hz for PAL)

7= not applicable

* Lock or AFL is Accu-RATE Frame Lock

DVS 406 • Serial Communication

3-3

Image 37
Contents DVS Consignes de Sécurité Français Safety Instructions EnglishSicherheitsanleitungen Deutsch Instrucciones de seguridad EspañolRear panel audio inputs Rear panel video inputsRear panel video output Rear panel audio outputMain menu Default Cycle menuInput menu Output menuMemory Presets menu Audio Configuration menuAdvanced Configuration menu DVS 406 Quick Start QS-3Executive Mode menu Picture Adjustments menuExit menu QS-4 DVS 406 Quick StartTable of Contents Table of Contents, cont’d One About this Manual What is the DVS 406?About the DVS Controlling the DVS 406 digital video scalerFeatures Features and OptionsIntroduction, cont’d Options and accessoriesInstallation and Operation Mounting the Scaler DVS 406 Installation and OperationTabletop use Rack mountingExtron DVS Application diagramDVS 406 AD rear panel connectors Rear Panel FeaturesOnly DVS 406 D and DVS 406 AD models have an SDI connector Installation and Operation, cont’d Picture adjustment buttons Front Panel FeaturesInput selection buttons Take buttonOptimizing the System Setting up a DVD sourceLCD menu display and controls Moving through menus by using front panel controls Menus, Configuration, and AdjustmentsMenu overview Input Configuration Resolution and refresh rates Output ConfigurationInput Video Type #1 Input Video Type #2 and #3Available Scaler Output Resolutions and Rates 50 Hz Audio Configuration56 Hz 60 Hz 75 Hz Lock @ 50/60 True 72/100 Output Sync RGB formatAudio Switch Memory PresetsAudio Level Clear memory presets Save Save memory presetsRecalling a preset Top and bottom blanking blanking adjustment Advanced ConfigurationEffect type Edge smoothingSwitch mode RGB delay Triple-Action SwitchingBlue mode Key modePulldown detection PAL film mode detect Image AdjustmentsReset Exit MenuFront Panel Security Lockout Adjust knobs have no mechanical limits to their rotationSelecting a preset IR 901 Infrared Remote ControlSelecting an input Freezing an inputOperating Problems TroubleshootingDVS 406 Installation and Operation Installation and Operation, cont’d Three RS-232 Programmer’s Guide Error responsesHost-to-scaler communications Scaler-initiated messagesSymbol definitions Using the command/response tablesSerial Communication, cont’d Command Ascii Command Response Additional descriptionTint Top blanking Values Command Ascii Command ResponseUsing the control program Installing the softwareControl Software for Windows Using the help program Serial Communication, cont’d AAppendix DVS 406 Appendix SpecificationsAudio Accessories Part Numbers and AccessoriesAccessories Part number Included partsRemove 13 screws from top and sides Lift Cover Straight Up Firmware Upgrade InstallationU41 Audio card standoffs Audio Card InstallationPin socket on back of audio card Pin connector on main board SDI connector opening SDI card standoff Serial Digital Interface SDI Card InstallationPin socket on back of SDI card Pin connector on main board FCC Class a Notice Extron’s Warranty Extron Electronics, USA