Serial Communication

The DVS 406 can be remotely controlled via a host computer or other device (such as a control system) attached to the rear panel RS-232 connector. The control device (host) can use either Extron’s Simple Instruction Set (SIS) commands or the graphical control program for Windows.

The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control.

The rear panel RS-232 9-pin D connector has the following pin assignments:

Pin

RS-232 function

Description

1

No connection

2

Tx

Transmit data

3

Rx

Receive data

4

No connection

5

Gnd

Signal ground

6

No connection

7

No connection

8

No connection

9

hardwired IR

IR input

5 1

96

DB9 Pin Locations

Female

RS-232 Programmer’s Guide

Host-to-scaler communications

SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence. When the DVS 406 determines that a command is valid, it executes the command and sends a response to the host device. All responses from the scaler to the host end with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. A string is one or more characters.

It is also possible to send several SIS commands back-to-back in sequence.

Scaler-initiated messages

When a local event such as a front panel selection or adjustment takes place, the DVS 406 scaler responds by sending a message to the host. No response is required from the host. The scaler-initiated messages are listed here (underlined).

(C) Copyright 2002, Extron Electronics, DVS 406, Vx.xx

The DVS 406 sends the copyright message when it first powers on. Vx.xx is the firmware version number.

Error responses

When the scaler receives a valid SIS command, it executes the command and sends a response to the host device. If the DVS 406 is unable to execute the command because the command is invalid or it contains invalid parameters, it returns an error response to the host.

The error response codes and their descriptions are as follows:

E01 – Invalid input channel number (the number is too large)

E10 – Invalid command

E11 – Invalid preset number

E13 – Invalid value (the number is out of range/too large).

E17 – Illegal command for this signal type.

3-2 DVS 406 • Serial Communication

Image 36
Contents DVS Safety Instructions English Consignes de Sécurité FrançaisSicherheitsanleitungen Deutsch Instrucciones de seguridad EspañolRear panel video inputs Rear panel audio inputsRear panel video output Rear panel audio outputDefault Cycle menu Main menuInput menu Output menuAudio Configuration menu Memory Presets menuAdvanced Configuration menu DVS 406 Quick Start QS-3Picture Adjustments menu Executive Mode menuExit menu QS-4 DVS 406 Quick StartTable of Contents Table of Contents, cont’d One What is the DVS 406? About this ManualAbout the DVS Controlling the DVS 406 digital video scalerFeatures and Options FeaturesOptions and accessories Introduction, cont’dInstallation and Operation DVS 406 Installation and Operation Mounting the ScalerTabletop use Rack mountingApplication diagram Extron DVSRear Panel Features DVS 406 AD rear panel connectorsOnly DVS 406 D and DVS 406 AD models have an SDI connector Installation and Operation, cont’d Front Panel Features Picture adjustment buttonsInput selection buttons Take buttonSetting up a DVD source Optimizing the SystemLCD menu display and controls Menus, Configuration, and Adjustments Moving through menus by using front panel controlsMenu overview Input Configuration Output Configuration Resolution and refresh ratesInput Video Type #1 Input Video Type #2 and #3Audio Configuration Available Scaler Output Resolutions and Rates 50 Hz56 Hz 60 Hz 75 Hz Lock @ 50/60 True 72/100 Output Sync RGB formatMemory Presets Audio SwitchAudio Level Save Save memory presets Clear memory presetsRecalling a preset Advanced Configuration Top and bottom blanking blanking adjustmentEffect type Edge smoothingRGB delay Triple-Action Switching Switch modeBlue mode Key modeImage Adjustments Pulldown detection PAL film mode detectReset Exit MenuAdjust knobs have no mechanical limits to their rotation Front Panel Security LockoutIR 901 Infrared Remote Control Selecting a presetSelecting an input Freezing an inputTroubleshooting Operating ProblemsDVS 406 Installation and Operation Installation and Operation, cont’d Three Error responses RS-232 Programmer’s GuideHost-to-scaler communications Scaler-initiated messagesUsing the command/response tables Symbol definitionsCommand Ascii Command Response Additional description Serial Communication, cont’dTint Top blanking Command Ascii Command Response ValuesInstalling the software Using the control programControl Software for Windows Using the help program Serial Communication, cont’d AAppendix Specifications DVS 406 AppendixAudio Part Numbers and Accessories AccessoriesAccessories Part number Included partsFirmware Upgrade Installation Remove 13 screws from top and sides Lift Cover Straight UpU41 Audio Card Installation Audio card standoffsPin socket on back of audio card Pin connector on main board Serial Digital Interface SDI Card Installation SDI connector opening SDI card standoffPin socket on back of SDI card Pin connector on main board FCC Class a Notice Extron’s Warranty Extron Electronics, USA