Barco MGD 521 MKII user manual Appendix B Technical Specifications, Picture tube

Page 36

APPENDIX B:

TECHNICAL SPECIFICATIONS

Picture tube:

Faceplate transmission: +/- 32%

Faceplate type: ARC panel

Image representation: portrait

Phosphor: P45 (standard) or P104 (option for MGD 521 MKII only)

Light output: (P45 phosphor)

MGD 521: Calibrated: 300 Cd/m2

MGD 521M: Calibrated: 400 Cd/m2

Peak: 600 Cd/m2

Resolution:

Max. adress. pixels:2048

Max. adress. lines: 2560

Scanning systems

Horizontal scanning:

Multi sync: µ-controller controlled

Minimum frequency: 160 kHz

Maximum frequency: 200 kHz

Minimum blanking : 1.28 µs

Storable scan frequencies: 16

Prealigned scans: 1 or 2

Vertical scanning: Minimum frequency: 48 Hz Maximum frequency: 150 Hz

Minimum blanking: 250 µs (after leading edge)

Geometry

Nominal size (4/3 ratio): 300mm x 400mm

Nominal size (4/5 ratio): 304mm x 380mm

Inputs

Video

BNC connectors

Nominal level: 0.7 Vpp

Sync

BNC connectors Nominal level: 0.5 Vpp

Communication inputs/outputs RS232 9-pin sub D connector Baudrate: 9600

Power supply:

Voltage: 100 - 240 V +/- 10%

Frequency: 50/60 Hz

Current: 2.3 A

Environmental

Temperature range (°C):

Storage: -20/+65

Operation: 0/+45

Within specs: 15/+30

Altitude: storage: 25 000 ft

operational: 10 000 ft Humidity (relative): 95 % max., non condensing

Weight:

UnpackedPacked

 

39.8 kg

58.3 kg

Dimensions packing:

H x W x D: 788mm x 630mm x 780mm

Dimensions monitor (mm):

Height: 558

Width: 400

Depth: 561

Modifications reserved.

Technical specifications

37

Image 36
Contents MGD 521 Mkii V599326/Rev JuneTrademark information MGD 521 M Mkii Users Guide Safety Instructions MGD 521 M Mkii Users Guide Contents MGD 521 M Mkii Users Guide Introduction OverviewPower saving system Versions and optionsAbout the manuals Installation PrecautionsPackage contents Controls and connectors Signal connection Connection of video signalsConnection of data signals Connection of optical sensorConnection of power Positioning the displayImportant considerations Switching on / off Power on/offAutomatic power saving system Dpms Operation User ControlsContrast and brightness control To activate the OSDTo put contrast in calibrated position To control contrast manually To put brightness in calibrated positionTo control brightness manually Viewing Status information To view the status informationExplanation of the Status information menu items Other adjustments Activity timeoutAdvanced Settings and Adjustments For Service Staff only SettingsTo change the settings Explanation of the Settings menu items Saving the settingsAdjustments How to make the adjustmentsDescription of the adjustments Geometry RotationAdvanced Interlacing Pre correction Interlacing Post correctionSH Compensation optional SH Compensation SH Compensation ON/OFFSH Compensation SH Position Advanced Advanced To adjust the ALC system, proceed as follows Focus Static focusFocus zone ALC optionalFactory reset How to save changes Proceed as followsLuminance uniformity What happens upon saving?Maintenance Picture tubeCabinet Troubleshooting There appears no image, the green LED is onAppendix a Background Information Luminance Uniformity CorrectionPage Appendix B Technical Specifications Picture tube