Stewart Filmscreen Corp 4-Way ScreenWall ElectriMask owner manual Electrical HOOK-UP

Page 12

STEP 2. ELECTRICAL HOOK-UP

Caution

Professional techniques need to be used when making any electrical connection. A qualified electrician should perform these procedures.

Be sure to follow all standard safety procedures for installing electrical devices.

Do not disassemble or alter the configuration of the motor or the unit's electrical connections. This may cause injury to you or damage to the product.

The electrical connection should be made only to the type of power source indicated on the marking label.

Electrical hook-up is required for each mask roller motor. The vertical masking systems have one roller motor at the top. Horizontal masking systems have a roller motor at the top and one at the bottom.

A motor requires standard AC power. All connections are made to the motor cables on the side of the unit (audience left).

There are several kinds of switch controls available. Follow the installation procedure for the type of switch control you will install.

General suggestions for wiring:

‹Soldering is recommended.

‹The use of wire nuts is acceptable.

Horizontal Mask Connection

Vertical Mask Connection

Horizontal Mask Connection

Figure 8: Electrical connections

10

Stewart Filmscreen Corporation

Image 12
Contents Way ScreenWall ElectriMask Page Contents Way ScreenWall ElectriMaskTo the Owner About your 4-Way ScreenWall ElectriMaskVertical Masking System Horizontal Masking SystemRow Diag Size 33/1 Size Table Attainable Aspect RatiosPreparing the Installation PreparationUnpacking Mounting the Frame Assembling the framePositioning the frame on the wall Wall BracketUnpacking and unrolling the screen Unrolling the screenAttaching the screen to frame Snapping screen onto frame Stewart Filmscreen CorporationConnecting the spring tension cable Spring Tension Cable Baby Eye Snap EyeletElectrical HOOK-UP Horizontal Mask Connection Vertical Mask ConnectionInstalling the high voltage switch control standard Screen SwitchPreparing the connection Making the connectionsInstalling the low-voltage 3-button switch option Button Momentary SwitchMaking the connection Low Voltage Control BoxInstalling the infrared remote control option Infrared Sensor Infrared Remote ControlInstalling the Multi-Channel Infrared Remote control option Mcir Control Board InfraredSensor Connecting the Video Interface Control System Vics Romex ConnectorTerminal Block To 12V Trigger Wire to Projector Conductor Cable 14ga Recommended Pin conductorsHanging the Frame on the Wall Hanging the screen Stewart Filmscreen CorporationAdjusting the Mask Extension Operating the MaskModifying the extension of the mask Horizontal Mask Vertical Mask ScreenScreen Care and Cleaning General maintenanceReplacement parts and service Velux coveringTroubleshooting Problem description Probable cause Action to takeProduct Warranty Adjustment. Failure to correc tProblem is resolved Can damage motor and screen