Stewart Filmscreen Corp 4-Way ScreenWall ElectriMask owner manual Romex Connector

Page 17

Connecting the Video Interface Control System (VICS)

Note: The VICS option should not be used for the horizontal masking system.

The VICS enables up and down operation of the mask in conjunction with a projector, tuner, VCR, cable box, or switched AC outlet.

Preparing the connection

Before making the electrical connections, you need:

‹An available AC constant power source

‹A 4-conductor cable (14ga)

Making the connection

Figure 13 illustrates the connections.

1.Use a screwdriver to open the VICS unit.

2.Feed the other end of the 4-conductor cable through the romex connector on the VICS unit.

3.Connect wires to the terminal block. For horizontal masking panels, connect the black motor lead to the black terminal block and the red motor lead to the red terminal block.For vertical masking panels, connect the red motor lead to the black terminal block and the black motor lead to the red terminal block.

4.Secure the clamp on the romex connector.

5.Replace the cover on the VICS.

6. Plug the AC power cord of the VICS into the AC outlet.

7. Attach the 12V trigger wire to the jack in the VICS.

4-Conductor Cable (14ga Recommended)

4-pin conductors

To AC Power Source

Romex Connector

LED

Terminal Block

To 12V Trigger Wire to

 

 

Projector

Figure 13: VICS connection

 

 

 

4-Way ScreenWall ElectriMask: Owner’s Manual

15

Image 17
Contents Way ScreenWall ElectriMask Page Way ScreenWall ElectriMask ContentsAbout your 4-Way ScreenWall ElectriMask To the OwnerVertical Masking System Horizontal Masking SystemSize Table Attainable Aspect Ratios Row Diag Size 33/1Unpacking Preparing the InstallationPreparation Assembling the frame Mounting the FrameWall Bracket Positioning the frame on the wallUnrolling the screen Unpacking and unrolling the screenSnapping screen onto frame Stewart Filmscreen Corporation Attaching the screen to frameSpring Tension Cable Baby Eye Snap Eyelet Connecting the spring tension cableHorizontal Mask Connection Vertical Mask Connection Electrical HOOK-UPScreen Switch Installing the high voltage switch control standardPreparing the connection Making the connectionsButton Momentary Switch Installing the low-voltage 3-button switch optionMaking the connection Low Voltage Control BoxInfrared Sensor Infrared Remote Control Installing the infrared remote control optionSensor Installing the Multi-Channel Infrared Remote control optionMcir Control Board Infrared Romex Connector Connecting the Video Interface Control System VicsTerminal Block To 12V Trigger Wire to Projector Conductor Cable 14ga Recommended Pin conductorsHanging the screen Stewart Filmscreen Corporation Hanging the Frame on the WallOperating the Mask Adjusting the Mask ExtensionHorizontal Mask Vertical Mask Screen Modifying the extension of the maskGeneral maintenance Screen Care and CleaningReplacement parts and service Velux coveringProblem description Probable cause Action to take TroubleshootingAdjustment. Failure to correc t Product WarrantyProblem is resolved Can damage motor and screen