Vidikron Vision 50 manual Exit to return to the previous menu or Menu to exit, Installation

Page 67

Operation

Lamp Hours: Lamp Hours indicates how long the currently-installed lamp has been in service. (This part of the menu is read-only.)

To access the Installation adjustments, press MENU, then press the or button to highlight Installation and press ENTER. The Installation sub-menu, shown at left, appears. Press EXIT to return to the previous menu or press MENU to close all menus.

When you change a setting in the Installation menu, the change takes

Note effect immediately; you do not need to press ENTER afterwards. (Press

EXIT to return to the previous menu or MENU to exit.)

Language: Press the or button to select from the available languages (English, French, Spanish, German and Italian).

Picture Configuration: Press the or button to change the orientation of the projected image. The Vision 50 can be installed on a ceiling or in a rear-screen configuration with one or more mirrors. There are four settings: Floor Front, Ceiling Front, Floor Rear and Ceiling Rear.

Keystone: To correct distortion resulting from the angle of projection, select Keystone and use the or button to make the image rectangular.

Vidikron recommends that the keystone feature not be used unless

Tip

absolutely necessary, as it may cause artifacts in the image.

 

OSD Position: To adjust the horizontal and vertical position of the OSD, select OSD Position and press ENTER. Then, press the or button to select Horizontal or Vertical and use the or button to adjust.

OSD Timer: Use the or button to set the OSD Timer. This timer controls how long the menus remain on-screen after selecting them. Select from 0 to 60 seconds, in 3-second increments. When you set the OSD Timer to 0, the menus remain on-screen until you hide them by pressing MENU.

PIP/PBP Setup: Select PIP/PBP Setup from the Installation menu to change the PIP/PBP settings.

PIP/PBP Enable: Press the or button to select PIP/PBP Enable, then press ENTER. Press the or button to select Off or On, then press ENTER.

PIP Set Up: Press the or button to select PIP Set Up, then press ENTER. Press the or button to select PIP Off, Graphic in Video or Video in Graphic, then press ENTER.

PBP Set Up: Press the or button arrows to select PBP Set Up, then press ENTER. Press the or button to select PBP Off, Graphic by Video or Video by Graphic, then press ENTER.

Background Color: Press the or button to select the image Background Color (grey, blue or white). The Background Color appears when no incoming signal is present.

Installation

Installation

Language

Picture Configuration

Keystone

OSD Position

OSD Timer

PIP/PBP Setup

Background Color

Vidikron Vision 50 Series Owner’s Operating Manual

55

Image 67
Contents Series DLP Projectors Page For Projectors, Video Processors and Controllers TWO Year Limited WarrantyEffective Warranty Date Vidikron Safety Precautions 1Table of Contents Operation Maintenance and TroubleshootingSerial Communications Table of Contents 1List of Figures List of Figures Xii About This Manual 1IntroductionIf you need Turn to Using This ManualThey also provide supplemental information Performance or cause a malfunctionDescription, Features and Benefits Optional Accessories Vision 50 at a Glance POWER/STANDBY LED Indicates power status as followsTemp LED Refer to Vision 50 Connector Panel, below Vision 50 Connector PanelCable Access Door Open to access connectors Volt 250 mA Trigger Output 3.5-mm, mini phono jack Comp 1 RCA connectorsBuilt-In Keypad Hdmi DigitalVision 50 Remote Control Vision 50 Remote ControlComp 2 HD Component On / OFFSource Selection Buttons Comp 1 SD Component VID S-VideoVAC V2 Aperture Control Memory Preset ButtonsCursor Keys Picture-In-Picture PIP / Picture-By-Picture PBP ControlsMotorized Lens Controls Remote Control/Built-In Keypad Functional ComparisonRemote Control 3InstallationOperation If installing a Vision 50/CineWide or Vision 50/CineWide Quick SetupInstallation Overview Step Procedure For Details, Refer toAdvantages Considerations Installation ConsiderationsProjector Installation Options Installation TypeVision Throw Ratios for the Vision 50 SeriesThrow Range Throw Ratio Projector ModelPosition Ceiling InstallationFloor Installation Vertical and HorizontalFolded Optics Installing the Optional CineWide Lens Mount With AutoScope Vision 50 with Ceiling Mount Adapters/Projector Stands AutoScope Lens Motor Installation Vision 50/CineWide with Lens Base Plate Installing the Fixed CineWide Base Plate Vision 50/CineWideCeiling Mounting Inverted Adjusting the ProjectorMounting the Vision Floor Mounting UprightHdmi or DVI Source Connector Panel AccessConnecting Source Connections to the VisionDVD Player or HD Set Top Box Personal Computer 10. RGB ConnectionsDTV or Progressive Component YPbPr Source 11. Progressive Component Video ConnectionsDTV Source DVD Player, VCR Satellite Receiver Etc 12. Composite, S-Video and Component Video Connections13. RS-232 Control System Connection Equipment 15. Connecting the 12-volt Trigger Output to Other EquipmentConnecting to AC Power Turning on the PowerPower source Focus Zoom Vertical Lens Shift Anamorphic Lens Installation Adjustment Vision 50/CineWide Installing and Adjusting the CineWide Anamorphic LensPrimary lens is perfectly centered on the screen Adjusting the Lens Height Y Anamorphic Lens Top View Vision 50/CineWide with AdjustmentAutoScope 18. Attaching the Anamorphic Lens to the Lens Adapter Ring Attach Lens Mounting Assembly to Lens Motor Carriage PlateAdjusting the Horizontal X Lens Position Installation Anamorphic Lens Top View Adjusting the Geometry Installation Selecting an Aspect Ratio Selecting An Input Source Using Picture-In-Picture/ Picture-By-Picture PIP/PBP4Operation Selecting Video MemoryUsing the On-Screen Menus Picture AdjustInstallation ServiceMain Menu Picture AdjustTypical Pluge Pattern for Adjusting Brightness Perform the adjustments in the order listed hereGray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Image Option Image OptionDescription Aspect Ratio SettingsRemote Projector Status Exit to return to the previous menu or Menu to exit InstallationService ServiceOperation Operation Remote Control ISF Calibration ISF CalibrationOperation Operation Lamp Replacement 5Maintenance and TroubleshootingLamp assembly for replacement Troubleshooting Chart Troubleshooting TipsSymptom Possible Causes Solution Temp and Lamp LEDs are both Maintenance and Troubleshooting 6Serial Communications Serial Command SyntaxRS-232 Connection and Port Configuration Serial CommandsSerial Communications Serial Commands Serial Commands Vision 50 Specifications 7SpecificationsDimensions Home Theater Calibration SpecificationsIndustry-Standard Specifications Power RequirementsSpecifications are subject to change without notice Limited WarrantyRegulatory Approvals Vision 50 Dimensions with Optional Fixed Anamorphic Lens Vision 50 DimensionsVidikron Vision 50 Series Owner’s Operating Manual Power-cycle the projector to see the change Page Vidikron