Teledyne 3190 manual Spare Parts List, Appendix Model

Page 40

Appendix

Model 3190

 

 

 

 

 

 

 

 

 

(95.3 mm H × 177.8 mm W). Face plate rated to NEMA-4.

Sensor Type: Class A-2C, B-2C, and Z-2C

Analysis Unit: 4.0" H × 6.0" W × 2.5" D

(101.6 mm × 152.4 mm × 63.5 mm)

A.2 Spare Parts List

QTY

P/N

1

C-65220-A

1

C-64586

1*

C-6689-B-2C

1*

C-6689-Z-2C

2

F-1130

1 F-51

1A-64678A

1* C-6689-A-2C

DESCRIPTION

PC Board, Main

PC Board, Power Supply Micro-Fuel Cell, class B-2C Micro-Fuel Cell, class Z-2C Fuse (AC), ½A, 250 VAC, IEC Type T, 5 x 20mm

Fuse (DC), ½A, 125 VDC, Micro-Fuse Probe to Analyzer Cable, 6 ft Micro-Fuel Cell, class A-2C

*Order one type only: A-2C, B-2C, or Z-2C. See Specific Model Informa- tion in front of this manual for cell class supplied with your analyzer.

A minimum charge is applicable to spare parts orders.

IMPORTANT: Orders for replacement parts should include the part number and the model and serial number of the system for which the parts are intended.

Send orders to:

Teledyne Analytical Instruments

16830 Chestnut Street

City of Industry, CA 91749-1580

Telephone: (626) 934-1500

Web Site: www.teledyne-ai.com

Fax: (626) 961-2538, (626) 934-1651

Technical Support: (626) 534-1673

Web: www.teledyne-ai.com

or your local representative.

A-2

Teledyne Analytical Instruments

Image 40
Contents Model 3190 Series Teledyne Analytical InstrumentsCopyright 1999 Teledyne Analytical Instruments Specific Model Information Contents Maintenance AppendixTeledyne Analytical Instruments Main Features of the Analyzer IntroductionOverview Trace Oxygen Analyzer IntroductionFront Panel Description Introduction ModelRear Panel Description Up ArrowAnalog Outputs Rear Panel AC and DC versionsRS-232 Port Introduction Model Teledyne Analytical Instruments Operational Theory IntroductionMicro-Fuel Cell Sensor Trace Oxygen Analyzer Operational TheoryOperational Theory Model Anatomy of a Micro-Fuel CellElectrochemical Reactions + 2H 2O + 4e → 4OHCalibration Characteristics Effect of PressureElectronics Signal ProcessingGeneral Block Diagram of the Signal Processing Electronics Trace Oxygen Analyzer Installation InstallationUnpacking the Analyzer Installation Model Control Unit InstallationExternal Probe Installation Location and MountingInstalling the Micro-Fuel Cell / Cell Block Orientation Electrical ConnectionsRear Panel Electrical Connectors for AC and DC Units Trace Oxygen Analyzer Installation HI Alarm LO AlarmParameter Setting Sensor FailInstallation Checklist Gas ConnectionsInstallation Model Teledyne Analytical Instruments Operation Using the Function and Data EntryTrace Oxygen Analyzer Operation Buttons Setting the Analysis RangesOperation Model Setting the Alarm Setpoints Settle ModeHI Alarm Trace Oxygen Analyzer Operation HI RangeLO Alarm Sensor Fail AlarmSelecting a Fixed Range or Autoranging CalibrationProcedure Displaying Percent & PPM on the LED DisplaySetL mode in the LED display Maintenance Trace Oxygen Analyzer MaintenanceAC Powered Units Replacing the FuseSensor Installation or Replacement Maintenance ModelDC Powered Units When to Replace a SensorDisconnect the Power Source at the Control Unit Removing the Micro-Fuel CellInstalling a Micro-Fuel Cell Exploded View of MFC and Cell BlockDisconnect the Power Source from the Control Unit Cell Warranty ConditionsMaintenance Model Teledyne Analytical Instruments Appendix Specifications Trace Oxygen Analyzer AppendixSpare Parts List Appendix ModelDrawing List MiscellaneousAppendix Model Teledyne Analytical Instruments