Teledyne 3190 manual Front Panel Description, Introduction Model

Page 8

1 Introduction

Model 3190

 

 

 

 

 

 

 

 

 

Two concentration alarms with adjustable setpoints.

Sensor failure alarm.

RS-232 serial digital port for output of concentration and range data to a computer, terminal, or other digital device.

Three analog outputs: two for measurement (0–10 V dc, and negative ground 4–20 mA dc) and one for range identification (0-10 V dc).

Compact and rugged Control Unit with flush-panel case. Designed for indoor use. Front panel NEMA-4 rated.

External Probe can be located six feet or more away, depending on the existing electromagnetic noise level.

1.3Front Panel Description

All controls and displays except the power switch are accessible from the front panel. See Figure 1-1. The front panel has seven pushbutton mem- brane switches, a digital meter, and an alarm indicator LED for operating the analyzer. These features are described briefly here and in greater detail in Chapter 4, Operation.

Figure 1-1: Front Panel

Function Keys: Seven pushbutton membrane switches are used to select the function performed by the analyzer:

1-2

Teledyne Analytical Instruments

Image 8
Contents Model 3190 Series Teledyne Analytical InstrumentsCopyright 1999 Teledyne Analytical Instruments Specific Model Information Contents Maintenance AppendixTeledyne Analytical Instruments Main Features of the Analyzer IntroductionOverview Trace Oxygen Analyzer IntroductionFront Panel Description Introduction ModelRear Panel Description Up ArrowAnalog Outputs Rear Panel AC and DC versionsRS-232 Port Introduction Model Teledyne Analytical Instruments Operational Theory IntroductionMicro-Fuel Cell Sensor Trace Oxygen Analyzer Operational TheoryOperational Theory Model Anatomy of a Micro-Fuel CellElectrochemical Reactions + 2H 2O + 4e → 4OHCalibration Characteristics Effect of PressureGeneral Signal ProcessingElectronics Block Diagram of the Signal Processing Electronics Unpacking the Analyzer InstallationTrace Oxygen Analyzer Installation Installation Model Control Unit InstallationExternal Probe Installation Location and MountingInstalling the Micro-Fuel Cell / Cell Block Orientation Electrical ConnectionsRear Panel Electrical Connectors for AC and DC Units Trace Oxygen Analyzer Installation HI Alarm LO AlarmParameter Setting Sensor FailInstallation Checklist Gas ConnectionsInstallation Model Teledyne Analytical Instruments Trace Oxygen Analyzer Operation Using the Function and Data EntryOperation Operation Model Setting the Analysis RangesButtons Setting the Alarm Setpoints Settle ModeHI Alarm Trace Oxygen Analyzer Operation HI RangeLO Alarm Sensor Fail AlarmSelecting a Fixed Range or Autoranging CalibrationProcedure Displaying Percent & PPM on the LED DisplaySetL mode in the LED display Maintenance Trace Oxygen Analyzer MaintenanceAC Powered Units Replacing the FuseSensor Installation or Replacement Maintenance ModelDC Powered Units When to Replace a SensorDisconnect the Power Source at the Control Unit Removing the Micro-Fuel CellInstalling a Micro-Fuel Cell Exploded View of MFC and Cell BlockDisconnect the Power Source from the Control Unit Cell Warranty ConditionsMaintenance Model Teledyne Analytical Instruments Appendix Specifications Trace Oxygen Analyzer AppendixSpare Parts List Appendix ModelDrawing List MiscellaneousAppendix Model Teledyne Analytical Instruments