Sanyo TLS-224P Output Terminals, Remote Jack, SW OUT Terminal Output Setting

Page 27

OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

SW OUT Terminal Output Setting

1Press the AUDIO ON/MENU button until the (SET UP 4) menu is displayed.

°The FIELD (or FRAME) setting is flashing.

<SET UP 4>

öSW OUT

 

FIELD

01

TIMING

FIELD

3H

Y

<USED TIME>

VIDEO 00000H

POWER 00000H

NOTE:

If “TIMING” is set to FRAME (see step 4), “FRAME” will be indicated instead of “FIELD”.

2Press the l (or j) button, to set the pulse signal interval.

Available settings are:

FIELD . . . . . . . . . . 01, 02, 03, 04, 05, 10, 30 or

60 field

FRAME . . . . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 frame

3Press the ] button to select the output timing.

4Press the l (or j) button, to set “FIELD” or “FRAME”.

FIELD . . . . . . . . . . 1 pulse is output after each set number of fields.

FRAME . . . . . . . . . 1 pulse is output after each set number of frames.

5Press the ] button.

°The “3H” setting starts flashing.

6Press the l (or j) button, to set the “3H”.

Y . . . . . . . . . . . . . . When recording in 3-hour mode, a pulse signal is output.

N . . . . . . . . . . . . . . When recording in 3-hour mode, a pulse signal is not output.

7Press the PAUSE/SCAN button, the normal screen is displayed.

REMOTE Jack

You can use a VA-RMN01 Remote Control Unit (sold separately) to control remotely the VCR.

Remote control of the VCR is possible by connecting a remote controller with a circuit such as indicated below, to the REMOTE jack.

NOTES:

Use a 3.5 mm mini-jack type plug.

The connection should be done using a shielded cable no more that 5 meters long.

Remote control circuit

GB

R1

1.5K

SW1: STOP

 

 

R2

0.43K

SW2: PAUSE/STILL

 

 

R3

0.51K

SW3: REW

 

 

R4

0.62K

SW4: FF

 

 

R5

0.75K

SW5: PLAY

 

 

R6

0.91K

SW6: REC

 

 

R7

1.1K

SW7: MENU

 

 

R8

1.3K

SW8: Do not use

 

 

R9

2.0K

SW9: TIMER, j

 

 

R10 2.4K

SW10: REC/PLAY SPEED, l

 

R11 3.6K

SW11: TRACKING/V.STILL –, ]

 

R12 5.6K

SW12: TRACKING/V.STILL +, «

 

The resistance tolerance is 2% or less.

NOTES:

The functions not available on the VCR will not operate.

The REC/PLAY SPEED j button on the VA-RMN01 will function as the TIMER button on the VCR.

26

English

Image 27
Contents DeutschD EnglishGBLocation PrecautionsMoisture Condensation Problems Power on/stand-by modeContents FeaturesFront Panel Locations of Controls and IndicatorsPLAY, STOP, FF or REW button Locations of Controls and IndicatorsDigital Display Operation Indicators Operation Mode IndicatorBack Panel 123456789Video ConnectionsButtons functions Types of ON-SCREEN Displays and Display SequenceDay of week is set automatically Setting the Language and ClockLanguage Setting Clock settingChanging the ON-SCREEN Display Selecting the On-screen DisplayChanging the Date/Time Display Position Video Cassette Tapes Normal Recording Record indicator a lights Recording startsPause/Still indicator blinks Normal RecordingEject button Normal RecordingRecording Check Clog DetectionAutorepeat Recording Setting the Mode at the End of the TapeAlarm Mode setting is flashing Repeat LED will light Setting procedure is now completedAlarm Recording Setting Alarm RecordingChecking the Alarm Recordings Time Alarm RecordingAlarm Recording Counter Display Connections to the Alarm IN/OUTPlayback will start, alarm scan mode is cancelled Alarm ScanProgramme Timer Recording To Cancel a Programme Timer Recording Programme Timer RecordingSetting the Holidays Changing a Programme Timer Recording700PM 800PM 900PM 1000PM Programme Recording Using AN External Timer Input Vertical Lock Control Normal PlaybackNormal Playback Tracking ControlStill Image Special PlaybackPicture Search Frame AdvanceSetting the Security Lock Setting the BuzzerIs displayed on the digital display To Condensation Checking Usage DurationCOM Terminal Tape END OUT Terminal Output SettingOutput Terminals Tape END OUT TerminalRemote Jack SW OUT Terminal Output SettingOutput Terminals SW OUT TerminalMaintenance Troubleshooting Guide After a Power FailureSystem Down General Specifications SpecificationsNE4QG/EX