TROUBLESHOOTING GUIDE

If the unit does not operate normally when you follow the instructions indicated in the manual, please refer to the table below.

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

 

 

 

 

 

 

 

No power

The power cord is not connected

Connect the power cord

 

 

No image displayed on

The connections are not correct

Check that all connections are correct

 

 

the monitor TV

 

 

 

 

The power to the camera and/or monitor

Turn all connected devices power on

 

 

 

TV is not turned on

 

 

 

The buttons do not

A cassette tape is not loaded

Load a cassette and turn the power on

 

 

respond

All functions are suspended due to

Wait for the “À” indicator to go off

 

 

 

condensation

 

 

 

 

Alarm recording

Wait for the alarm recording to end

 

 

 

The security lock is engaged

Cancel the security lock

 

 

Recording is not

The loaded cassette has no

Load a cassette tape with

 

 

 

GB

possible (the tape is

erasure-prevention tab

erasure-prevention tab or cover the tab

 

ejected)

 

hole with adhesive tape

 

 

 

 

 

Autorepeat recording is

“AL” is displayed on the digital display

Display (ALARM TIME) menu, then press

 

 

not possible

 

the MENU RESET button to turn off the

 

 

 

 

“AL” indicator

 

 

 

 

 

 

 

Timer recording is not

The date and time are not set correctly

Set the date and time correctly

 

 

possible

 

 

 

 

The unit is not set to timer recording

Press the TIMER button to display “n” on

 

 

 

stand-by mode

the digital display

 

 

 

“N” is selected for the timer recordings

Be sure to select “Y” for the programmed

 

 

 

 

timer recordings

 

 

 

 

 

 

 

Alarm recording is not

“OFF” is displayed on the digital display

Press the EJECT, STOP, FF, REW or

 

 

possible

 

PLAY button to turn the indicator off

 

 

 

 

 

 

 

Noise in the playback

The video heads need cleaning

Clean the video heads

 

 

picture

 

 

 

 

The date and time are

The ON SCREEN switch is set to the

Set the ON SCREEN switch to the “ON”

 

 

not recorded

“OFF” position

position

 

 

The cassette tape

Problem with the system

Turn the power off, then on again

 

 

cannot be ejected

 

 

 

 

 

 

 

 

 

After a Power Failure

If after a power failure the recording speed is reset to 3-hour mode, it is due to insufficient backup battery charge. This is not a malfunction.

System Down

If the unit does not function at all, try the following.

1Unplug the power cord then plug it back in.

2Reset the memory. (Press the ALL RESET button. Under normal conditions, do not touch the ALL RESET button.)

3If the problem is not corrected after performing steps 1 and 2 a few times, consult your dealer.

28

English

Image 29
Contents DeutschD EnglishGBMoisture Condensation Problems PrecautionsPower on/stand-by mode LocationContents FeaturesFront Panel Locations of Controls and IndicatorsDigital Display Operation Indicators Locations of Controls and IndicatorsOperation Mode Indicator PLAY, STOP, FF or REW buttonBack Panel 123456789Video ConnectionsButtons functions Types of ON-SCREEN Displays and Display SequenceLanguage Setting Setting the Language and ClockClock setting Day of week is set automaticallyChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Video Cassette Tapes Pause/Still indicator blinks Record indicator a lights Recording startsNormal Recording Normal RecordingRecording Check Normal RecordingClog Detection Eject buttonAlarm Mode setting is flashing Setting the Mode at the End of the TapeRepeat LED will light Setting procedure is now completed Autorepeat RecordingAlarm Recording Setting Alarm RecordingAlarm Recording Counter Display Alarm RecordingConnections to the Alarm IN/OUT Checking the Alarm Recordings TimePlayback will start, alarm scan mode is cancelled Alarm ScanProgramme Timer Recording Setting the Holidays Programme Timer RecordingChanging a Programme Timer Recording To Cancel a Programme Timer Recording700PM 800PM 900PM 1000PM Programme Recording Using AN External Timer Input Normal Playback Normal PlaybackTracking Control Vertical Lock ControlPicture Search Special PlaybackFrame Advance Still ImageIs displayed on the digital display Setting the Security LockSetting the Buzzer To Condensation Checking Usage DurationOutput Terminals Tape END OUT Terminal Output SettingTape END OUT Terminal COM TerminalOutput Terminals SW OUT Terminal Output SettingSW OUT Terminal Remote JackMaintenance System Down Troubleshooting GuideAfter a Power Failure General Specifications SpecificationsNE4QG/EX