Sanyo RD2QD/NA, DTL-4800 Connections, Power Cord Installation, About the memory reset

Page 11

CONNECTIONS

Connect the video camera and monitor TV as shown in the figure below.

NOTE: Before making the connections, make sure the devices are disconnected from the power outlet.

Video camera (sold separately)

To

VIDEO IN jack

IN OUT

IN OUT

VIDEO

S-VIDEO

AC IN

 

Power cord

To

 

VIDEO

 

OUT

 

jack

IN OUT

AUDIO

A RS485 B

ADDRESS 485 TERMINATE

ON ON

PUSH OFF 232OFF OPEN

REMOTE

RS232C

Monitor TV (sold separately)

From an external audio source

MIC IN

EXT

TIMER WARNING TAPE

SW

COM NON REC V.LOSS

TIMER IN OUT

OUT

END OUT OUT

 

OUT

OUT

IN

OUT

COM

IN

OUT

COM

IN

OUT

CLOCK SET

 

SERIES

 

EJECT

ALARM

 

TRIGGER

IN

OUT

 

 

RESET

 

SHOT REC

ALARM

 

 

IN

 

IN

 

 

 

 

 

To remote control (sold separately)

To outlet

Coaxial cable

(sold separately)

 

Power Cord Installation

1Plug the supplied power cord firmly into the AC power input AC IN ~ socket.

2Insert the plug of this power cord into a outlet.

About the memory reset

If the VCR location is changed or to cancel previous settings, please reset the memory as described below.

To reset the memory, press the ALL RESET button.

NOTE:

œThe time and date will be reset, and the quick method security lock will be cancelled. The (SECURITY LOCK) menu data cannot be reset.

NOTES:

œFor more details, please refer to the manuals accompanying all other devices. If the connections are not made properly, it may cause a fire or damage the equipment.

œYou can use a VA-RMN01 Remote Control Unit (sold separately) to control remotely the VCR.

œThe grounded power cord (3 pin plug) must be connected to a grounded power outlet.

œIf there is no video signal when the power is turned on, “NO VIDEO” will be displayed on-screen.

œWhen both the VIDEO IN jack and S-VIDEO IN jack are connected, the S-VIDEO IN jack will have priority.

œWhen a multiplexer is used, a connection must be made between the SW OUT terminal on the VCR and the SW IN terminal on the multiplexer. If the connection is not made, depending on the recording mode a part of the image may not be recorded.

10

English

Image 11
Contents Digital Declaration of Conformity PrecautionsFor the customers in Canada Precautions Accessories ContentsFeatures Search FRAME/FIELD button Eject button Menu Exit button Locations of Controls and IndicatorsFront Panel STILL/PAUSE buttonDigital Display Locations of Controls and IndicatorsOperation Indicators Operation Mode IndicatorOFF indicator Male on the VCR Back PanelO P Q R S T Connections Installing the Ni-Cd BatteryProtection against power failure Connections Power Cord InstallationAbout the memory reset Sub-menus ON-SCREEN MenusMain menus ON-SCREEN Menus Day of week is set automatically Setting the Language and ClockLanguage Setting Clock SettingAutomatic Daylight Saving Time Adjustment Setting the Language and ClockChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Video Cassette Tapes Various SET 1 menu appears Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes Correct tape thread check functionIf tape management data is present on the tape Tape Management FunctionOperation If no tape management data is present on the tapeTape Management menu appears Setting the Tape Management FunctionTape Management Function Conflict display sample Tape Management Conflict DisplayNormal Recording Before starting Recording speed mode is displayed on the digital displayPause/Still indicator N blinks Normal RecordingHour Recording Speed ModeNormal Recording FieldClog Detection Concerning the Number of Times Tapes can be Rerecorded onRecording Check Record SET menu appears Setting the Mode at the End of the TapeAction to Take when the Video Signal Deteriorates Setup for use with a multiplexer Changes to the Recording Speed Mode During RecordingAutorepeat Recording Repeat indicator will lightAutorepeat Recording Alarm Recording Setting Alarm RecordingAlarm Reset in terminal Alarm RecordingAlarm Recording Counter Display Connections to the Alarm IN/OUT TerminalsAlarm Scan Alarm SearchRecording speed mode Recording duration Seconds Pre Alarm Recording SettingPost Alarm Recording Setting Program Timer Recording Press the Data l or j button to select Y Program Timer RecordingTo Cancel all Program Timer Recordings Setting the HolidaysChanging a Program Timer Recording To Cancel a Program Timer RecordingThese portions will not be recorded Recording Using AN External Timer Input Trigger Shot Recording Connections Using a MultiplexerTrigger Shot Recording Setup Series recording connections Series Recording SetupRecording will start in series recording mode Series RecordingLoop recording connection example with 2 VCRs Continous Loop Recording SetupSeries Recording Playback Field Advance Forward and Reverse Tape CounterPlayback Search Forward and ReverseD Search 01 000000 will be displayed on screen DAY/TIME SearchDay/Time Search Setting and Canceling the Quick Method Security Lock Setting the Security LockSetting the Security Lock Cancel the Security LockBuzzer SET menu appears Setting the BuzzerIf using the SET UP setting, continue with steps 4 Setting procedure on the first VCR is now completed Clock AdjustmentEject in terminal Setting the Cassette Eject ModeCassette Eject Setup Eject terminal connectionExample Setup for RS-232C or RS-485 USEDIP Switches Setup SW NoRS-485 Connection Setup for RS-232C or RS-485 USESetup for RS-232C or RS-485 Use RS-485 RJ-11 connector layoutPOWER/DEW/USED Time menu appears RS-232C 9-pin connector layoutPin Signal Operation Signal direction COM Terminal Timer OUT TerminalOutput Terminals Tape END OUT TerminalNON REC OUT terminal Remote control settingOutput Terminals Remote JackMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyRD2QD/NA
Related manuals