OUTPUT TERMINALS
TAPE END OUT Terminal
œDuring recording, when the end of the tape is reached or when approximately 5% of the tape remains, the output becomes 0V (Low).
œTo reset the output, press the STOP or EJECT button.
œDuring autorepeat recording, when the end of the tape is reached, the output becomes 0V (Low) for about 2 seconds only.
End of the tape or approximately 5% of the tape remaining Output reset
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)
TAPE END OUT Terminal Output Setting
1Press the MENU button to display the (MAIN MENU 1) menu.
2Press the SHIFT ] button to select the “4. VARIOUS SET 1” line, then press the MENU button.
øThe (VARIOUS SET 1) menu appears.
@@@@<VARIOUS@SET@1>
*THREAD@CHECK@@@@Y
*REMOTE@@@@@@@@@@EJECT
*EXT@TIME@ADJ.@@@01:00
*TAPE@END@OUT@@@@PRE
*EJECT@SET
@@EJECT@MODE@@@@@EJECT1
@@OPERATION@@@@@@SLAVE
3Press the SHIFT ] (or \) button, until the “TAPE END OUT” setting is flashing.
4Press the DATA l (or j) button to select the desired output mode.
PRE . . . . . . . The output becomes 0 V (Low) when approximately 5% of the tape remains (if recording has been started at the beginning of the tape) and/or when the end of the tape is reached (if recording has not been started at the beginning of the tape).
END . . . . . . . The output becomes 0 V (Low) when the tape reaches the end.
5Press the MENU EXIT button to save the setting.
WARNING OUT Terminal
œIf the tape stops or other problem (the heads are dirty, there is a problem with the battery or the cooling fan, etc.) the output becomes 0V (Low).
œTo reset the output, press the STOP or ALL RESET button or unplug the power cord then plug it back in.
Tape movement stop
Output reset
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)
NOTE:
œIf the output is 0V (Low) due to the clog detect function, it can be reset by simply pressing the STOP button.
TIMER OUT Terminal
œDuring timer recording DC 12 V (High) are output. (During timer recording
Timer recording
12V (H)
(Output impedance: 5.7 kΩ) 0V (L)
COM Terminal
œCommon GND (ground) terminal when connecting other terminals to external devices.
SW OUT Terminal
When recording, a pulse signal is output at the SW OUT terminal.
This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.
FIELD: 16.7 msec.
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)