Sanyo DTL-4800, RD2QD/NA instruction manual Alarm Recording Setting

Page 28

ALARM RECORDING

By connecting the ALARM IN terminal to a door switch, an interphone, etc., a recording can be done only when necessary.

Alarm Recording Setting

Alarm recording is performed when there is an input (trigger) at the ALARM IN terminal, “A” is displayed on the digital display.

œMake all necessary connections.

œFollow the Before starting steps, under “NORMAL RECORDING”.

œThe alarm triggers are received while in recording and stop modes.

1Press the MENU button to display the (MAIN MENU 1) menu.

2Press the SHIFT ] button to select the “6. RECORD SET” line, then press the MENU button.

øThe (RECORD SET) menu appears.

@@@@@<RECORD@SET>

*ALARM@RECORD@MODE@@Y1

@@SPEED@@@@@@@@@@@@@N12

@@DURATION@@@@@@@@@@20S

*PRE@ALARM@RECORD@@@OFF

*POST@ALARM@RECORD@@OFF

@@DURATION@@@@@@@@@@20S

*TRIGGER@SHOT@REC@@@1

*TAPE@END@MODE@@@@@@REW

3Press the DATA l (or j) button to set the desired alarm recording mode, then press the SHIFT ] button.

Y1. . . . . . Alarm recording is done when there is an alarm trigger.

Y2. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording.

Y3. . . . . . Alarm recording is done only if there is an alarm trigger and the VCR is not in programmed timer recording mode.

Y4. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording duration. Timer recording is not possible.

N. . . . . . Alarm recording is not performed even if there is an alarm trigger.

4Press the DATA l (or j) button to select the desired recording speed, then press the SHIFT ] button.

N12. . . . . N12-hour mode recording

U12. . . . . U12-hour mode recording

H12. . . . . H12-hour mode recording

F12 . . . . . F12-hour mode recording

H24. . . . . H24-hour mode recording

F24 . . . . . F24-hour mode recording

NC . . . . . Recording at the speed already set

5Press the DATA l (or j) button to select the desired alarm recording duration (20S, 40S, 1M, 2M, 3M, 4M, 5M or CC).

20S-5M. . Recording only for the displayed duration

CC. . . . . Recording as long as the alarm signal is being input (minimum 5 seconds)

6Press the MENU EXIT button to save the settings.

NOTES:

œDuring alarm recording all buttons are disabled.

œIf “OFF” is displayed on the digital display, alarm recording is not possible in order to prevent the recorded tape to be recorded over.

œIf an alarm trigger is received while alarm recording is in progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan and alarm search.

œIf there is a power failure during alarm recording, and the power is restored within the recording set duration, alarm recording will continue.

œIf the alarm recording duration is short, the alarms may not be found during an alarm scan or an alarm search. If the alarms are going to be reviewed using alarm scan or alarm search, then in 12-hour mode,

60-second or more recording duration should be used.

œTo do alarm recording during series recording, set “ALARM RECORD MODE” to “Y1” or “Y3”. Alarm recording will be conducted only if the VCR is recording.

English

27

Image 28
Contents Digital For the customers in Canada PrecautionsDeclaration of Conformity Precautions Features ContentsAccessories Locations of Controls and Indicators Front PanelSTILL/PAUSE button Search FRAME/FIELD button Eject button Menu Exit buttonLocations of Controls and Indicators Operation IndicatorsOperation Mode Indicator Digital DisplayOFF indicator Back Panel Male on the VCRO P Q R S T Protection against power failure Installing the Ni-Cd BatteryConnections About the memory reset Power Cord InstallationConnections Main menus ON-SCREEN MenusSub-menus ON-SCREEN Menus Setting the Language and Clock Language SettingClock Setting Day of week is set automaticallySetting the Language and Clock Automatic Daylight Saving Time AdjustmentSelecting the On-screen Display Changing the ON-SCREEN DisplayChanging the Date/Time Display Position Video Cassette Tapes Setting the Action to Take When a Cassette is Loaded Video Cassette TapesCorrect tape thread check function Various SET 1 menu appearsTape Management Function OperationIf no tape management data is present on the tape If tape management data is present on the tapeTape Management Function Setting the Tape Management FunctionTape Management menu appears Tape Management Conflict Display Conflict display sampleRecording speed mode is displayed on the digital display Pause/Still indicator N blinksNormal Recording Normal Recording Before startingRecording Speed Mode Normal RecordingField HourRecording Check Concerning the Number of Times Tapes can be Rerecorded onClog Detection Action to Take when the Video Signal Deteriorates Setting the Mode at the End of the TapeRecord SET menu appears Changes to the Recording Speed Mode During Recording Setup for use with a multiplexerAutorepeat Recording Repeat indicator will lightAutorepeat Recording Alarm Recording Alarm Recording SettingAlarm Recording Alarm Recording Counter DisplayConnections to the Alarm IN/OUT Terminals Alarm Reset in terminalAlarm Search Alarm ScanPost Alarm Recording Setting Pre Alarm Recording SettingRecording speed mode Recording duration Seconds Program Timer Recording Program Timer Recording Press the Data l or j button to select YSetting the Holidays Changing a Program Timer RecordingTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Trigger Shot Recording Setup Connections Using a MultiplexerTrigger Shot Recording Series Recording Setup Recording will start in series recording modeSeries Recording Series recording connectionsSeries Recording Continous Loop Recording SetupLoop recording connection example with 2 VCRs Playback Tape Counter PlaybackSearch Forward and Reverse Field Advance Forward and ReverseDay/Time Search DAY/TIME SearchD Search 01 000000 will be displayed on screen Setting the Security Lock Setting the Security LockCancel the Security Lock Setting and Canceling the Quick Method Security LockIf using the SET UP setting, continue with steps 4 Setting the BuzzerBuzzer SET menu appears Clock Adjustment Setting procedure on the first VCR is now completedSetting the Cassette Eject Mode Cassette Eject SetupEject terminal connection Eject in terminalSetup for RS-232C or RS-485 USE DIP Switches SetupSW No ExampleSetup for RS-232C or RS-485 USE Setup for RS-232C or RS-485 UseRS-485 RJ-11 connector layout RS-485 ConnectionPin Signal Operation Signal direction RS-232C 9-pin connector layoutPOWER/DEW/USED Time menu appears Timer OUT Terminal Output TerminalsTape END OUT Terminal COM TerminalRemote control setting Output TerminalsRemote Jack NON REC OUT terminalMaintenance Maintenance Table MaintenanceMaintaining and Checking The Mechanism After a Power Failure Troubleshooting GuideSystem Down Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeRD2QD/NA