Sanyo DTL-4800, RD2QD/NA Setting the Tape Management Function, Tape Management menu appears

Page 20

TAPE MANAGEMENT FUNCTION

Setting the Tape Management Function

1Press the MENU button to display the (MAIN MENU 1) menu.

2Press the SHIFT ] button to select the “9. TAPE MANAGEMENT” line, then press the MENU button.

øThe (TAPE MANAGEMENT) menu appears.

@@@<TAPE@MANAGEMENT>

*TAPE@MANAGE.@@@@N

*PROTECT@DAY@@@@@30

*REC@PASS@SET@@@@10

*GROUP@NO.@@@@@@@OFF

*OVERRIDE@@@@@@@@N

3Press the DATA l (or j) button to select the desired mode.

N. . . . . . The tape management function is not active.

Y. . . . . . . The tape management function is active.

When setting to “Y”, please continue with the settings below.

4Press the SHIFT ] button, until the “PROTECT DAY” setting is flashing.

5Press the DATA l (or j) button, to select the desired number of days to protect the tape.

OFF . . . . The tape is not protected.

1-255 . . . Number of days to protect the tape (prevent over-recording), from the date of the last recording on the tape (or the last expected recording date (calculated using the tape length (ST-180XZES) and the recording speed).

NOTES:

œSince the last expected recording date is a calculated date (using the tape length (ST-180XZES) and the recording speed), it may be different from the actual last recording date, this due to other settings such as (alarm recordings, program timer recordings, holiday settings).

œWhen setting a program timer recording, the tape protection term is checked when the VCR is set to program timer recording stand-by mode.

œWhen a program timer recording is done, the data is updated when recording starts. Even if the recording is stopped before the programmed time, the original data (last expected recording date) will remain as calculated.

6Press the SHIFT ] button, until the “REC PASS SET” setting is flashing.

7Press the DATA l (or j) button, to select the desired number of re-recording times.

OFF . . . . The number of re-recording times will not be checked.

1-100 . . . Maximum number of re-recording times.

(Refer to “Concerning the Number of Times Tapes can be Rerecorded on” on page 23.)

NOTES:

œThe data is updated at the beginning of the recording. Even if the recording is stopped before the end, the original data information will be considered.

œDuring Autorepeat recording, the re-recording times count will be updated every time the tape is rewound to the beginning. Autorepeat recording will proceed even if the count exceeds the “REC PASS SET” setting. If in the (BUZZER SET) menu WARNING is set to “Y”, the buzzer is heard.

8Press the SHIFT ] button, until the “GROUP NO.” setting is flashing.

9Press the DATA l (or j) button, to select the desired group number.

OFF . . . . The group number will not be checked.

1-15 . . . . Group number setting.

FPress the SHIFT ] button, until the “OVERRIDE” setting is flashing.

GPress the DATA l (or j) button, to select the desired override mode.

Y . . . . . . . In case of a conflict that prevents recording, the next operation is executed. If recording is done, then the last recording date and the re-recording times count are updated.

N. . . . . . . In case of a conflict that prevents recording, the (TAPE MANAGEMENT) menu is displayed and the conflicting setting preventing recording will flash. The only possible action is to press the EJECT button, in order to eject the tape. (Refer to “Tape Management Conflict Display”.)

HPress the MENU EXIT button to save the settings.

NOTES:

œOnce the tape management data is recorded on tape, it cannot be changed.

œThe criteria (condition) for allowing recording will be based on the data recorded on the tape and not the settings in the (TAPE MANAGEMENT) menu.

English

19

Image 20
Contents Digital Declaration of Conformity PrecautionsFor the customers in Canada Precautions Accessories ContentsFeatures Locations of Controls and Indicators Front PanelSTILL/PAUSE button Search FRAME/FIELD button Eject button Menu Exit buttonLocations of Controls and Indicators Operation IndicatorsOperation Mode Indicator Digital DisplayOFF indicator Back Panel Male on the VCRO P Q R S T Connections Installing the Ni-Cd BatteryProtection against power failure Connections Power Cord InstallationAbout the memory reset Sub-menus ON-SCREEN MenusMain menus ON-SCREEN Menus Setting the Language and Clock Language SettingClock Setting Day of week is set automaticallySetting the Language and Clock Automatic Daylight Saving Time AdjustmentChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Video Cassette Tapes Setting the Action to Take When a Cassette is Loaded Video Cassette TapesCorrect tape thread check function Various SET 1 menu appearsTape Management Function OperationIf no tape management data is present on the tape If tape management data is present on the tapeTape Management menu appears Setting the Tape Management FunctionTape Management Function Tape Management Conflict Display Conflict display sampleRecording speed mode is displayed on the digital display Pause/Still indicator N blinksNormal Recording Normal Recording Before startingRecording Speed Mode Normal RecordingField HourClog Detection Concerning the Number of Times Tapes can be Rerecorded onRecording Check Record SET menu appears Setting the Mode at the End of the TapeAction to Take when the Video Signal Deteriorates Changes to the Recording Speed Mode During Recording Setup for use with a multiplexerAutorepeat Recording Repeat indicator will lightAutorepeat Recording Alarm Recording Alarm Recording SettingAlarm Recording Alarm Recording Counter DisplayConnections to the Alarm IN/OUT Terminals Alarm Reset in terminalAlarm Search Alarm ScanRecording speed mode Recording duration Seconds Pre Alarm Recording SettingPost Alarm Recording Setting Program Timer Recording Program Timer Recording Press the Data l or j button to select YSetting the Holidays Changing a Program Timer RecordingTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Trigger Shot Recording Connections Using a MultiplexerTrigger Shot Recording Setup Series Recording Setup Recording will start in series recording modeSeries Recording Series recording connectionsLoop recording connection example with 2 VCRs Continous Loop Recording SetupSeries Recording Playback Tape Counter PlaybackSearch Forward and Reverse Field Advance Forward and ReverseD Search 01 000000 will be displayed on screen DAY/TIME SearchDay/Time Search Setting the Security Lock Setting the Security LockCancel the Security Lock Setting and Canceling the Quick Method Security LockBuzzer SET menu appears Setting the BuzzerIf using the SET UP setting, continue with steps 4 Clock Adjustment Setting procedure on the first VCR is now completedSetting the Cassette Eject Mode Cassette Eject SetupEject terminal connection Eject in terminalSetup for RS-232C or RS-485 USE DIP Switches SetupSW No ExampleSetup for RS-232C or RS-485 USE Setup for RS-232C or RS-485 UseRS-485 RJ-11 connector layout RS-485 ConnectionPOWER/DEW/USED Time menu appears RS-232C 9-pin connector layoutPin Signal Operation Signal direction Timer OUT Terminal Output TerminalsTape END OUT Terminal COM TerminalRemote control setting Output TerminalsRemote Jack NON REC OUT terminalMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeRD2QD/NA