Zenith H20J55DT warranty Detailed Descriptions for Installer Menu Items 10-I through

Page 47

Installer Menu

Detailed Descriptions for Installer Menu Items 10-I through 27-I

Change values with ADJ (Adjust) Left/Right keys. It may be best to set the same value on every TV. Note: The maximum volume level cannot have a value setting lower than the MIN VOLUME level (See Item 8 -I).

10-I. MUTE DISABLE

Enables or disables sound mute function. If set to 1, sound cannot be muted. If set to 0, sound can be muted.

11-I. NOT USED

12-I. IR BANKS EN (IR Banks Enable)

For direct access to a particular Channel Bank. When enabled, installer can access a channel bank by inputting the IR code for the bank.

13-I. SCAN MODE

Allows variation in the On/Off setup with CHANNEL Up/Down. You may opt for TV channels only or TV channels + Off/On with the following settings for Scan Mode. Scan mode Characteristics:

0 = Channel Up/Down keys Change channels only.

1 = Channel Down below the lowest channel (or channel up higher than the highest channel) and the TV turns Off.

14-I. STRT CH IN SM (Start Channel in Scan Mode) If set to 1, installs TV On/Off event below the start channel at TV turn On.

15-I. SLEEP TIMER

If set to 1, the Sleep Timer feature is available (but no message is displayed prior to turn-Off). If set to 0, the Sleep Timer is not functional.

16-I. EN. TIMER (Enable Timer)

If set to 1, On/Off Timer functions are available to end user. Set to 0 to disable Timer functions. Note: Clock must be set in order to use Timers.

17-I. ALARM

Gives you the option of making the Alarm function available to the user. Set to 1, Alarm function is available to user. Set to 0 to disable the Alarm function. Note: Clock must be set in order to set the Alarm.

18-I. NOT USED

19-I. NOT USED

20-I. FEATURE LEVEL

Default set to ZEN 1 for Zenith IR remote control operation. Set O, P LBL for Zenith Private Label IR remote control operation.

WARNING: Do not change the default value unless you have the proper remote control

to operate the TV.

21-I. V-CHIP

Set to 1 to activate V-Chip (Parental Control); have it available to user to filter or control or restrict programming content. Set to 0 to turn V-Chip fea- ture Off, not available to user; no programming restrictions can be set.

22-I. MAX BLK HRS (Maximum Block Hours)

Set 0 to 99 for the maximum V-Chip (Parental Control) block hours. Default setup is for 12 block- ing hours.

23-I. CAPTION LOCK

Set to 1 to restore previous Caption On/Off state after TV turns Off. If set to 0, Captions are always Off, when TV is initially turned On.

24-I. TEXT MODE

Determines whether TEXT 1, TEXT 2, TEXT 3, or TEXT 4 decoding is enabled when TEXT is turned on (either from the Setup Menu or directly with CC on the remote).

TIP: Set Text Mode to 1 only if text is offered in your video system.

25-I. NOT USED

26-I. NOT USED

27-I. HOSPITAL MODE

The default is 2 (which favors most hospitals). With this setting two things are affected: Channel Banks 1, 2 and 3 are accessible, while Bank 4 is inactive. Hosp. Mode=0 Not hospital mode. IR code depends on Item 20-I setting.

“Inactive TV” features not available.

Hosp. Mode= 1 Zenith P.L. IR Code (Bed 1) Hosp. Mode= 2 Zenith IR Code (Bed 2)

206-4065

Page 47

Image 47
Contents Model Number H20J55DT HealthViewTM TV Installation Guide & WarrantyCopyright 2007, LG Electronics U.S.A., Inc Power Cord PolarizationRecord the H20J55DT Serialnumber Regulatory InformationImportant Safety Instructions Portable Cart Warning Table of Contents Features Analog Menus Digital Menus TV Features OverviewBrief overview of the features on this TV Set item 28-I CH Overide to H20J55DT Master TV SetupOverview Master TV Setup Procedure Verify Master TV SetupOver-the-Air Antenna Connect an over the air signal source to the TVHook Up an Off Air Antenna Cable Service Hook Up Cable Service CatvConnect cable service to the TV Cable Service with a Cable BoxOver-the-Air Antenna with VCR Connect an over-the-air signal source to the VCR and TVHook Up an Off Air Antenna with VCR Connect a cable box and VCR to the TV Cable Service with VCRHook Up a Cable Box with VCR Audio/Composite Video Hook Up Audio/Composite VideoConnect the TV to an audio/composite video source External Speaker Hook Up an External SpeakerConnect the TV to an external speaker or amplifier Controlling the TV with Serial Data Pillow Speaker Connection & SetupPillow Speaker Setup Pillow speaker is not included with the HealthView TVPillow Speaker Control Pillow Speaker SetupConnect a pillow speaker to the TV Keys descriptions and functions for the optional remote Optional Installer/User Remote ControlChannel Down/Up Using the front panel controls to operate the TVPower Front Panel ControlsOther Menus and On-Screen Displays On-Screen Menus/Displays OverviewDescriptions of the menus and on-screen status displays On-Screen MenusL U M E AUX Other Menus and On-Screen DisplaysAuto Program Channel Search Setup MenuBlank Add/Delete/Blank FeatureAdded DeletedNone Setting Preset Analog Channel LabelsSelecting channel names from the preset Channel Labels Typical Analog preset Channel Label options Analog Preset Channel LabelsCH32 ABC Setting Custom Labels for Digital ChannelsSetting channel names for Channel Labels Have the TV set the clock time or use Manual Clock Set Clock Setup Auto or ManualSetup Menu On-Off Timers SetupSet up Closed Caption/Text options for the end user Captions Captions Analog-Digital Menu StructuresAnalog Captions Menu Structure Digital Captions Menu StructureFrench Press OK to remove menu Audio Language for Digital ChannelsLanguage for the On-Screen Menus Alarm Menu Alarm MenuAnalog Channel Display Video MenuUse the Video Menu to customize the picture’s appearance Video MenuSAP Additional Digital Audio Program Selection Overview Things to Consider before Setting Up Parental ControlParental Control Menu Overview Options Setups for V-Chip Menu and Block Functions Installer Menu Options For V-Chip OperationDialog Language Sex Scenes Violence Violence No Rating Parental Control MenuTV Parental Guidelines Rating System Parental Control TV/Movie Rating GuidelinesParental Control for Digital Channels Advanced Rating Block Digital Channels using US Ratings Information messageAdding/Deleting Channels Channel Banks SetupPlanning The Channel Banks Inactive TV Display Channel BankAuto Program Adding / Deleting ChannelsDate Installer Menu Installer Menu Items 24-I through Installer Menu Items 62-I through Power Manage Power Management Installer Menu Items 89-I throughDetailed Descriptions of Installer Menu Items Installer SequenceStart Volume Detailed Descriptions for Installer Menu Items 2-I throughDetailed Descriptions for Installer Menu Items 10-I through Detailed Descriptions for Installer Menu Items 28-I through 74-I. CH-TIME Size Detailed Descriptions for Installer Menu Items 60-I through66-I. not Used 67-I. not Used 68-I. not Used 72-I. not UsedDetailed Descriptions for Installer Menu Items 77-I through 105-I. not Used 102-I. Atsc Band= HRC 104-I. Strt Minor CH Start Minor ChannelLT2002 QuickSet Clone Programmer Before You Begin Cloning Set Up a Master TVLT2002 QuickSet Programmer Cloning PreparationsCa. Set the Clock Optional Learn Setup from Master TVTeach Master TV’s Setup to Another Identical TV Master and Other TVs Clone Programmer/Cloning Procedure TroubleshootingReset Clone After Static Shock Installer Menu Settings and TV Problems Some Quick and Easy Tips for Resolving ProblemsSome Quick and Easy Tips for Resolving Problems Maintenance Glossary 206-4065 206-4065 206-4065 206-4065 Zenith HealthView TV Warranty