Panasonic TH-37PW4 How to connect the Serial Terminals, Communication parameters, Command

Page 14

Connections

How to connect the SERIAL Terminals

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

SERIAL

Ferrite core

RS-232C

(supplied)

straight cable

D-sub 9p

Less than

 

7" 7/8 (20 cm)

Notes:

(1)Use the RS-232C cable to connect the computer to the Plasma Display.

(2)The computers shown is for example purposes only.

(3)Additional equipment and cables shown are not supplied with this set.

6 7 8 9

1 2 3 4 5

Pin layout for RS-232C

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as a programming language to software. Refer to the documentation for the computer application for details.

Communication parameters

Signal level

RS-232C compliant

 

 

Synchronization method

Asynchronous

Baud rate

9600 bps

 

 

Parity

None

 

 

Character length

8 bits

Stop bit

1 bit

 

 

Flow control

-

 

 

 

RS-232C Conversion cable

D-sub 9-pin female

Details

2

 

R X D

3

 

T X D

5

 

GND

4

6

Non use

7

 

Shorted

8

 

 

 

1 •

9

NC

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX

 

 

 

 

Colon

 

Parameter(s)

 

End

 

 

 

 

 

 

Start

 

3-character

(1 - 5 bytes)

 

(03h)

 

 

(02h)

 

command (3bytes)

 

 

 

Notes:

(1)If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

(2)If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

 

Audio mute OFF

AMT

0

1

Audio mute ON

 

IIS

None

Input select (toggle)

 

VID

AV Mode

 

YP1

Component / RGB mode (processed as a

 

 

Y/PB/PR or RGB signals as set by this unit)

 

RG1

PC Mode

DAM

None

Screen mode select (toggle)

 

NORM

4 : 3

 

ZOOM

Zoom

 

FULL

16 : 9

 

JUST

Just

 

SELF

Panasonic Auto

With the power off, this display responds to PON command only.

14

Image 14
Contents English Operating Instructions TH-37PW4Wide Plasma Display Dear Panasonic Customer Trademark CreditsTable of Contents Important Safety Notice When using the Plasma Display Safety PrecautionsSetup If problems occur during use Cleaning and maintenanceSafety Precautions Optional Accessories AccessoriesAccessories Supply Check that you have the accessories and items shownObserve the following precaution Remote Control BatteriesPrecaution on battery use Helpful HintConnections Cable fixing bandsVideo 4 pin socket AV Input Terminals connectionConnections Component signals Y, PB, PR connection Component/RGB Input connectionRGB signal R, G, B, HD, VD connection How to connect the PC Input Terminals Signal Names for D-sub 15P ConnectorCommunication parameters How to connect the Serial TerminalsCommand Basic format for control dataBasic Controls Connecting the plug to the Wall Outlet Power On/Off and input signal selectionPower On/Off AC cord connectionSelecting the On-Screen Menu Language Select the input signalPower On/Off and input signal selection On-Screen Menu Display from Remote Control To Sound adjust menu SeeOn-Screen Menu Display from Remote Control Aspect Controls Just Aspect ControlsZoom PanasonicAdjusting Picture Pos./Size Adjusting screenHelpful Hint N / Normalise Normalisation Adjusting Picture Pos./SizePos Size Clock Phase RGB/PC in Mode Pos SizeBass Sound AdjustmentMute TrebleSurround Controls OffDynamic Picture AdjustmentsNormal CinemaPicture Adjustments On / Off selection Screensaver For preventing after-imagesReversal / Scroll selection To stop the Screensaver under On, press the buttonSide Panel Adjustment 3D Y/C Filter For Ntsc video images Setup for input signalsComponent/RGB-in select If the picture image becomes unstable Setup for input signalsColour system / Panasonic Auto Clamp position SyncPull-in range Freq kHz/V-Freq HzTroubleshooting Plasma Display panel Symptoms CheckSpecifications Specifications Customer’ Record