There are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.
TEMP indicator
Indicator | Illuminated (red) | Flashing (red) | Flashing (red) | |
display | (Lamp unit on) | (Lamp unit on) | (Lamp unit off) | |
|
|
|
| |
| The surrounding | The temperature | The surrounding | |
| temperature or the | inside the projector | temperature or the | |
| temperature inside | has become | temperature inside | |
| the projector has | dangerously high, or | the projector has | |
| become unusually | the temperature has | become dangerously | |
Problem | high. | suddenly changed. | high, causing the | |
|
|
| lamp unit to be | |
|
|
| automatically shut | |
|
|
| off. | |
|
|
|
| |
Possible | BThe ventilation holes may be covered. |
| ||
BThe ambient temperature in the place of use may be too high. | ||||
cause | BThe air filter may be blocked. |
| ||
|
|
|
| |
| BUncover the ventilation holes. |
| ||
| BSet up the projector in a place where the temperature is | |||
| between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is | |||
| between 20% and 80% (with no condensation). [If you set the | |||
Remedy | FAN CONTROL to “HIGH” (page 45), set up the projector in a | |||
place where the temperature is between 0 °C (32 °F) and 35 °C | ||||
| ||||
| (95 °F) and the humidity is between 20% and 80% (with no | |||
| condensation).] |
|
| |
| BTurn off the MAIN POWER switch by following the procedure | |||
| on page 29, and then clean the air filter (refer to page 62). | |||
|
|
|
|
| LAMP indicator |
| ||
|
|
|
| |
Indicator | Illuminated (red) | Flashing (red) | ||
display | ||||
|
|
| ||
|
|
|
| |
| It is nearly time to | An abnormality has been detected in the lamp | ||
Problem | replace the lamp | circuit. |
| |
| unit. |
|
| |
|
|
|
| |
| BDoes “REPLACE | BThe power may | BThere may be an | |
Possible | LAMP” appear on | have been turned | abnormality in the | |
the screen after | on straight away | lamp circuit. | ||
cause | ||||
the projector is | after it was turned |
| ||
|
| |||
| turned on? | off. |
| |
|
|
|
| |
| BThis occurs when | BWait for a while | BTurn off the MAIN | |
| the operation time | until the lamp unit | POWER switch by | |
| for the lamp unit is | cools down before | following the | |
| nearing 1 300 | turning the power | procedure given | |
| hours. (when | back on again. | on page 29, and | |
| LAMP POWER |
| then contact an | |
Remedy | has been set to |
| Authorised | |
“HIGH”) Ask your |
| Service Centre. | ||
|
| |||
| dealer or an |
|
| |
| Authorised |
|
| |
| Service Centre to |
|
| |
| replace the lamp |
|
| |
| unit. |
|
| |
|
|
|
| |
NOTE: |
|
|
|
BBe sure to turn off the MAIN POWER switch by following the procedure given in “Turning off the power” on page 29 before carrying out any of the procedures in the “Remedy” column.
BIf the main power turns off after the TEMP indicator starts flashing, it means that an abnormality has occurred. Please contact an Authorised Service Centre so that the necessary repairs can be made.