Controlling the Monitor with a PC (LAN)

■ NETWORK (LAN SETUP)

This screen allows you to set the settings necessary when the monitor is connected to a LAN.

DHCP CLIENT

If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to “ON”.

To set the address manually, set this to “OFF”.

IP ADDRESS

If the DHCP CLIENT is set to “OFF”, specify an IP address.

SUBNET MASK

If the DHCP CLIENT is set to “OFF”, specify the subnet mask.

DEFAULT GATEWAY

If the DHCP CLIENT is set to “OFF”, specify the default gateway.

If you are not using a default gateway, specify “0.0.0.0”.

DNS SERVER

Specify the DNS server address.

If you are not using a DNS server, specify “0.0.0.0”.

RESET

Clicking [Execute] returns all of the LAN SETUP settings to the factory-preset values except for the DNS SERVER setting.

TIPS

When the IP address is set manually, the IP addresses of the monitor connected to the RS-232C output terminal and the daisy chain of connected monitors that follows can be assigned automatically. (See page 23.)

■ NETWORK (SECURITY)

This screen allows you to specify the security-related settings.

USER NAME / PASSWORD

Sets up a user name and password to restrict access to this monitor.

After entering a user name and password, click [Apply].

ACCEPT IP ADDRESS

You can limit access to this monitor by registering IP addresses of PCs that should have access.

To limit access, specify the option “From only specific IP addresses”. Otherwise, to allow access from any PC, specify “All IP Addresses”.

IP ADDRESS 1 to 3

If “ACCEPT IP ADDRESS” is set to “From only specific IP addresses”, enter the IP addresses that you want to allow.

TIPS

The USER NAME and PASSWORD can be up to 8 alphanumeric characters or symbols.

To cancel the user name and/or password after it has been set, make the box empty and click [Apply].

E46

Image 46
Contents PN-E702 Blue For Customers in U.KGREEN-AND-YELLOW BrownRefer Servicing to Qualified Service Personnel Important InformationEuropean Union Information on Disposal for Users private householdsInformation on Disposal for Business Users Other Countries outside the EUDear Sharp Customer Safety Precautions Tips and Safety Instructions For the monitor in portrait orientation For the monitor in landscape orientationDo not place the monitor on a device which generates heat Contents Supplied ComponentsNFront view Part NamesNRear view Power button See Mute button See NRemote control unit Part NamesSignal transmitter 11 EConnecting Peripheral Equipment Connection with a PC or AV equipmentConnecting Peripheral Equipment 13 ERemoving the Handles Connecting the Power CordBinding Cables Handles can be removedRemote control operation range Preparing the Remote Control UnitInstalling the batteries 15 ETurning power on/off Turning Power On/OffTurning on the main power Main power switchNDate/time setting Disabling power on/off operationsNOperation mode Turning Power On/OffMenu Basic OperationMute DisplayWide Zoom Normal Basic Operation NSwitching the screen size19 E Dot by DotNExample of operation Menu ItemsDisplaying the menu screen NMenu screen displayNSCREEN 21 EMenu item details Menu Items NPICTUREMenu Items NSETUPNAUDIO 23 E NOPTIONNMULTI NPIP/PbyP 25 EMenu Items NDual screen display Set using the Multi menu NZOOM2 Special SettingSetting procedure Menu Items NEnlargeNSCHEDULE Power27 E DAY of the WeekNAutomatic adjustment Adjustments for PC screen displayNScreen display for adjustment 29 E PC connection Communication procedureControlling the Monitor with a PC RS-232C Communication conditionsNResponse code format 31 ENID numbers VOLM0020 ← 002VOLM0030 OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←Setting of the Gamma user data 33 EHow to read the command table RS-232C command tablePower control/Input mode selection Command Command field See Direction35 E Controlling the Monitor with a PC RS-232C Screen menuControlling the Monitor with a PC RS-232C Picture menu 37 E Setup menuControlling the Monitor with a PC RS-232C Audio menu Controlling the Monitor with a PC RS-232C Option menu Controlling the Monitor with a PC RS-232C Multi menu Image Position Epos setting39 E Landscape orientation Portrait orientationInitialization/Functional Restriction Setting Function menu Controlling the Monitor with a PC RS-232C PIP/PbyP menu41 E Commands for setting of the Gamma user dataControlling the Monitor with a PC RS-232C Others Controlling the Monitor with a PC LAN Settings to connect to a LANTo set on the monitor To set from a PC Default Gateway 0.043 E Controlling the Monitor with a PC LANBasic operation See pages 45 to 49 for details on each settingControlling with a PC If the Dhcp Client is set to OFF, specify an IP address45 E Standby mode, Power on is the operation availableInformation about this monitor appears DNS Server User Name / PasswordIf the Dhcp Client is set to OFF, specify the subnet mask Accept IP Address47 E Condition Attach the log file to a TEMPERATURE/HARDWARE error e-mailRecipient E-MAIL Addresses Confirmation49 E Troubleshooting Troubleshooting 51 ESpecifications NProduct Specifications53 E NDimensional Drawings SpecificationsNPower management NDDC plug and playSpecifications NCompatible signal timing PC NCompatible signal timing AV55 E Mounting Precautions For Sharp dealers and service engineers PN-E702 Me EN11K1