Pelco c1943m operation manual Input VCR Connectors, VCR Input Plugs

Page 7

IMPORTANT:

Control cable length should not

be extended further than the supplied 50 feet (15.2 m). It is also recommended that shielded cable be used to minimize external electrical interference with VCRC-P control signals.You should also avoid ground loops of any kind. See important note in Figure 9 regarding power hookup and interference.

INPUT VCR CONNECTORS

Physically, each of the four VCRC-P input connectors consists of the same number of input screw-type terminals. Each input group uses a dual-row removable plug and each plug is associated with 8 VCR inputs.

For example, refer to the leftmost group represented in Figure 5, which shows VCR inputs

1-16. Of these VCR inputs, 1-8 are wired using the top 16 screw terminal positions. VCR in- puts on this connector physically alternate with their associated GND connection for a total of 8 available VCR/GND connections: that is, pin 1 is VCR input 1 and pin 2 is the GND connection associated with VCR input 1; pin 3 is VCR input 2 and pin 4 is VCR input 2’s as- sociated GND connection, and so on. The same explanation applies to the lower plug for VCR inputs 9-16, starting with VCR input 9, which is associated with physical pin 17 on the mating plug.

Similarly, the remaining plug (upper/lower) combinations accommodate the three remaining VCR input blocks: that is, inputs 17-32 are handled by header two, inputs 33-48 by header three, and inputs 49-64 by header four.

Figure 5. VCR Input Plugs

Pelco Manual C1943M (9/99)

7

Image 7
Contents CM9760-VCRC-P Contents Description Important Safeguards and WarningsFront View PRE-INSTALLATION InformationModels OptionsLEDs DIP SwitchesRear View of CM9760-VCRC-P Rear ViewVCR Input Plugs Input VCR ConnectorsCommunication Connectors Relay Output ConnectorDB-9 Connector Pin-outs Power Input Fuse Replacement Power ConnectionsDIP Switch Settings Setup Preliminary DiscussionDIP Switch Functions Configuring MGR Camera File for VCRC-P Operation Configuring the GPI Setup file for VCRC-P Operation Configuring the Comms file for VCRC-P Operation DAISY-CHAINING InstallationDirect RACK-MOUNT HOOK-UP Remote OperationOperational Overview Functional Block DiagramCM9760-KBD VCR Control Functions Operating the CM9760-VCRC-P from the CM9760-KBDElectrical SpecificationsRegulatory Notices Product Warranty and Return Information