RS-232C interface
1.Introduction
(1)The VTR can be operated by commands when the
(2)Conditions for acknowledging commands from
The front panel REMOTE/LOCAL switch must be at REMOTE. The setup menu No. 204 “RS232C SEL” must be ON.
If the above conditions are not met, [ACK] + [STX]ER001[EXT] is returned to the external unit.
Whether the [ACK] code is returned depends on the setting which has been selected for setup menu item No. 209 “RETURN ACK”.
2.Hardware specifications
External interface specifications
1)Connector specifications
Connector:
Pin No. | Signal | Circuit name | Description |
|
|
|
|
1 | FG | Protective ground | Frame ground |
|
|
|
|
2 | RXD | Received data | Data is sent to PC. |
|
|
|
|
3 | TXD | Transmitted data | Data is received from PC. |
|
|
|
|
4 | CTS | Clear to send | Shorted with pin 5. |
|
|
|
|
5 | RTS | Request to send | Shorted with pin 4. |
|
|
|
|
6 | DTR | Data terminal ready | No processing |
|
|
|
|
7 | SG | Signal ground | Signal ground |
|
|
|
|
20 | DSR | Data set ready | + voltage output after communication enable status |
|
|
|
|
2)Example of connection with controller (PC)
■Using crossover cable with
■Using crossover cable with
PC side |
|
| |
connector) | VTR side |
FG | 1 | 1 | FG |
TXD | 2 | 2 | RXD |
RXD | 3 | 3 | TXD |
RTS | 4 | 4 | CTS |
CTS | 5 | 5 | RTS |
DSR | 6 | 6 | DTR |
SG | 7 | 7 | SG |
DTR | 20 | 20 | DSR |
PC side
RXD | 2 |
TXD | 3 |
DTR | 4 |
SG | 5 |
DSR | 6 |
RTS | 7 |
CTS | 8 |
VTR side
1FG
2RXD
3 TXD
4CTS
5RTS
6DTR
7SG
20 DSR
106 (E)