Video output (encoder output) signal adjustments
After this system has been connected, the video output signal (ENCODER OUT) must be adjusted if AB roll editing (editing using two source machines) using an editor, for instance, is to be
The adjustment procedure using this unit is outlined below.
1 Check the connections. (see page 23.)
2 Set setup menu No. 10 (ENCODER SEL) to “LOCAL”.
REMOTE: For adjusting the video output signals using an external encoder remote controller.
LOCAL: For adjusting the video output signals using this unit.
3 Adjust the source machine independently.
Set the PRESET/MANUAL switches of the VIDEO OUT LEVEL, CHROMA LEVEL, BLACK LEVEL and CHROMA PHASE controls to PRESET.
1Play back a cassette tape on which standard colour bar signals have been recorded.
2Adjust the controls in such a way that the waveforms on the waveform monitor (WFM) and vectorscope (VSC) resemble those shown in the figures below.
ABlack level
Adjust the control to eliminate deviation.
BVideo level
Adjust this level to 700 mV.
CChroma level and chroma phase
Adjust the two controls in such a way that the light spot of the vector wave- forms comes inside the rectangular grid mark.
■ Waveform on WFM | ■ Waveform on VSC |
B
C
A
4 Perform the same adjustments on the source machine connected to the unit.