Panasonic AJ- HD3700B manual For your safety Europe

Page 4

For your safety (Europe)

Caution for AC Mains Lead

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.

This product is equipped with 2 types of AC mains cable. One is for continental Europe, etc. and the other one is only for U.K.

Appropriate mains cable must be used in each local area, since the other type of mains cable is not suitable.

FOR CONTINENTAL EUROPE, ETC.

Not to be used in the U.K.

FOR U.K. ONLY

If the plug supplied is not suitable for your socket outlet, it should be cut off and appropriate one fitted.

FOR U.K. ONLY

This appliance is supplied with a moulded three pin mains plug for your safety and convenience.

A 13 amp fuse is fitted in this plug.

Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362.

Check for the ASTA mark Ï or the BSI mark Ì on the body of the fuse.

If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced.

If you lose the fuse cover the plug must not be used until a replacement cover is obtained.

A replacement fuse cover can be purchased from your local Panasonic Dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.

If a new plug is to be fitted please observe the wiring code as shown below.

If in any doubt please consult a qualified electrician.

WARNING: THIS APPLIANCE MUST BE EARTHED.

IMPORTANT: The wires in this mains lead are coloured in accordance with the following code:

Green-and-Yellow: Earth

Blue:Neutral

Brown:Live

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked with the letter E or by the Earth symbol Ó or coloured GREEN or GREEN-AND-YELLOW.

The wire which is coloured BLUE must be connected to the terminal in the plug which is marked with the letter N or coloured BLACK.

The wire which is coloured BROWN must be con- nected to the terminal in the plug which is marked with the letter L or coloured RED.

How to replace the fuse

1. Open the fuse compartment with a screwdriver.

2. Replace the fuse.

Fuse

– 4 –

Image 4
Contents Operating Instructions Hardware Is the safety information For your safety GeneralOperating precaution For your safety FCC NoteFor your safety Europe For Your Safety Please Read the Following Text CarefullyContents Features Picture/sound quality at a reasonable priceOperation and maintenance Specifications and interfacesSlow motion, search and editing functions Controls and their functions Audio Monitor1415 16 Cursor≥ENT ≥BS≥FROM ≥COPY UNITY/VAR28 29 32 TC/CHR SET UP Test DiagVideo Video OUT Audio Audio OUT Button After editing Shtl button JOG button VAR button Search dialEntry button 44454647484950 Power supply part Digital signal input/output sectionConnectors BNCt4 FuseAnalog input/output section 1513141617CUE OUT Remote Remote control sectionParallel Connections Connection for a single unitConnection for 2 units Connection with an editing controller Tapes ONoteNPreparation ∑ Release the recording inhibit mode ∑ Selecting the input signals and adjusting their levelsRecording ≥Confirm that the REC Inhibit lamp has gone outPreparation ∑ Setting the time code OperationSimultaneous playback monitoring ∑ Video monitoring ∑ Checking the input signals∑ Audio monitoring How to display the ≥SYSTEM SET UP menu Menus Home Audio TC/CHR Recording ∑ Monitoring the audio signals ∑ Adjusting the audio levelPlayback Press the Play buttonBasic operations ∑ Stop∑ Shuttle Shtl ∑ Jog≥Preset variable mode ∑ Variable VAR∑ Tape speed override TSO function When TC Input is set to the Standard mode∑ Cue When TC Input is set to the Reverse mode Ceding the cue point by the preroll timePress the F key and Preroll button together. This results Cue-up operation∑ Correction of the cue point Move the cursor to the place which is to be correctedEnter the new value with the number keys Press the ENT key ≥Cue points cannot be clearedManual editing Manual editing Mode Fade Manual audio cross editingAutomatic insert/assemble editing ONoteN Audio split editing ONotesNOUT point preview Set the F3 W/PLYR key to OFF Variable memory FunctionSet the F4 VAR Memo key to on Plyr Connector signals ∑ Parallel I/O 50P connector Pin no Signal Direction Type Description≥50P error status output table FF Status Output Activel Signal Pin No Video head cleaning ∑ Maintenance∑ Operation ∑ StorageRack-mounting Troubleshooting How to eject the tape in an emergencyDIP switch AV microcomputer DIP switch specificationsSyscon microcomputer DIP switch specifications Servo microcomputer DIP switch specificationsSpecifications GeneralInput connectors Output connectorsVideo adjustment ranges Video systemAudio input connectors Audio output connectorsAudio Cue trackAudio adjustment ranges Other input/output signalsAccessory supplied Optional accessoryPage Panasonic Broadcast Europe