JVC BR-D95U specifications Video Signal System Selection, Pal

Page 16

4 MENU SWITCH SETTING

4-2 VIDEO SIGNAL SYSTEM SELECTION

This unit can be used with either the NTSC or PAL signal systems. The currently selected video signal system is indicated by the 525/625 indicator on the counter display. To change the video signal system, follow the steps below.

4 MENU SWITCH SETTING

 

 

 

4-3 MENU SWITCH SETTING

 

 

 

 

 

 

 

 

 

VIDEO CASSETTE RECORDER

BR-D95U

AUDIO

AUDIO INPUT / AUDIO MONITOR SELECT

VIDEO

 

POWER

INPUT

INPUT

 

 

SDI

CH1

CH2

CH3

CH4

SIF

 

 

AUDIO

AES/EBU

CH1

CH2

CH3

CH4

LINE

ON

I

MONITOR

L

 

 

 

ANALOG

CH1

CH2

CH3

CH4

CPN

COMPONENT DIGITAL

 

 

R

 

Video signal system indicator

525 : NTSC

OFF

O

Variable Motion

 

AUDIO INPUT / AUDIO MONITOR SELECT

SDI

CH1

CH2

CH3

CH4

SIF

AES/EBU

CH1

CH2

CH3

CH4

LINE

L

ANALOG

CH1

CH2

CH3

CH4

CPN

R

625

: PAL

 

 

VIDEO CASSETTE RECORDER

BR-D95U

 

 

POWER

 

ON

I

COMPONENT DIGITAL

OFF

O

 

 

CH1

 

CH2

 

CH3

CH4/TRACKING

 

R

P

R

P

R

P

R

P

 

dB OVER dB

dB OVER dB

dB OVER dB

dB OVER dB

 

+4

0

+4

0

+4

0

+4

0

 

 

 

 

 

 

+2

–10

+2

–10

+2

–10

+2

–10

 

0

–20

0

–20

0

–20

0

–20

 

–2

–30

–2

–30

–2

–30

–2

–30

 

–4

–40

–4

–40

–4

–40

–4

–40

 

 

–60

 

–60

 

–60

 

–60

 

PHONES

CH1

 

CH2

 

CH3

CH4

 

TRACKING

 

 

REC

 

 

 

 

 

PULL FOR VARIABLE

 

METER MODE

 

 

 

 

 

 

 

FINE

TRACKING

CTL TC UB DF SERVO CF GEN 16:9 AP 525

AUTO OFF P.READ V.VAR PB/EE REMOTE 625

 

H

M

 

S

ASSEM

VIDEO

DA1

DA2

DA3

IN

ENTRY

OUT

INSERT

 

 

CANCEL

PREVIEW

AUTO EDIT

 

 

 

 

VCON

SEARCH

VAR

PLAYER RECORDER

CONDITION

 

COUNTER

RESET

REMOTE

 

 

 

 

 

 

 

 

 

 

 

UB

 

 

 

 

 

 

 

MENU

SET

HOLD

PB

P.PLAY

 

 

 

PB/EE

 

 

 

 

 

 

 

 

STILL

F

 

 

 

 

 

 

 

DA4

EJECT

REC

PLAY

PAUSE/STILL

 

X1

 

 

 

 

 

X-1

 

TC

TOP

 

VIDEO

AUDIO

 

 

 

 

 

 

 

STAND BY

REW

STOP

FF

 

 

PREROLL

Jog dial

Variable Motion

[SEARCH] button

 

CH1

 

CH2

 

CH3

CH4/TRACKING

 

 

 

 

 

 

 

 

SEARCH

VAR

PLAYER RECORDER

R

P

R

P

R

P

R

P

 

 

525

 

 

COUNTER

RESET

VCON

REMOTE

 

 

 

OVER

 

OVER

 

OVER

OVER

CTL TC UB DF SERVO CF GEN 16:9 AP

CONDITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO OFF P.READ V.VAR PB/EE REMOTE

625

 

 

UB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

SET

HOLD

PB

P.PLAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB/EE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STILL

 

 

 

 

 

 

 

H

 

M

S

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSEM VIDEO

DA1

DA2

DA3

DA4

EJECT

REC

PLAY

PAUSE/STILL

 

 

PULL

RELEASE

PLAY

SHIFT

 

REVIEW

PULL

RELEASE

USER

SERVO/SYS TIME CODE ON SCREEN

OTHERS

REV

FWD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-1

X1

PHONES

CH1

CH2

CH3

CH4

TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

REC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

ENTRY

OUT

INSERT

TC

TOP

 

VIDEO

AUDIO

 

 

 

 

PULL FOR VARIABLE

 

METER MODE

CANCEL PREVIEW

AUTO EDIT

PREROLL

STAND BY

REW

STOP

FF

 

 

PULL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULL

RELEASE

 

 

PLAY

 

SHIFT

 

REVIEW

 

USER

SERVO/SYS

TIME CODE

ON SCREEN

OTHERS

 

RELEASE

 

 

 

 

 

 

REV

FWD

Jog dial

[MENU] button

[HOLD] button

 

 

[SET] button

[MENU] button

[HOLD] button

 

[SET] button

[Counter display]

H

M

S

F

[On-screen display]

D95:525/625 SET+HOLD[POWER OFF>525 00A:MENU SETTING SET+HOLD INITIAL 00B:DIRECT ACCESS SET+HOLD>ON 00C:USER PAGE SET+HOLD>INITIAL 00D:MENU LOCK SET+HOLD>OFF

Operation procedure

1.Press the [MENU] button to display the top menu.

2.Turn the jog dial to select “D95: 525/625”. ÒD95Ó is shown on the counter display and ÒD95Ó blinks on screen.

3.Hold the [SEARCH] button down and turn the jog dial to select the set value.

Select Ò525Ó for NTSC or Ò625Ó for PAL.

 

 

 

D95:525/625

4.

To change the menu switch setting, hold the

 

 

 

SET+HOLD[POWER OFF>525

 

[SET] button down and press the [HOLD]

 

 

 

00A:MENU SETTING

 

 

 

 

SET+HOLD INITIAL

 

button.

 

 

 

00B:DIRECT ACCESS

 

H

M

S

SET+HOLD>ON

 

[ The Normal Display mode is restored.

F

 

 

 

 

 

00C:USER PAGE

 

 

 

 

 

SET+HOLD>INITIAL

5.

To apply the selected video signal system, turn

 

 

 

00D:MENU LOCK

 

 

 

SET+HOLD>OFF

 

this unit OFF then ON again.

 

 

 

 

 

 

 

 

 

 

[ When the power is turned ON, the video signal

 

 

 

 

 

system is changed and the corresponding

 

 

 

 

 

video signal system indicator is shown on the

 

 

 

 

 

counter display (525 or 625 indicator).

[Counter display]

 

 

[On-screen display]

 

 

 

 

 

 

 

 

 

Top menu display

 

 

 

 

 

 

 

 

 

D95:525/625

 

 

 

 

 

 

 

 

 

SET+HOLD[POWER OFF>525

 

M

 

 

 

 

 

 

00A:MENU SETTING

H

S

F

SET+HOLD INITIAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00B:DIRECT ACCESS

 

 

 

 

 

 

 

 

 

SET+HOLD>ON

 

 

 

 

 

 

 

 

 

00C:USER PAGE

 

 

 

 

 

 

 

 

 

SET+HOLD>INITIAL

 

 

 

 

 

 

 

 

 

00D:MENU LOCK

 

 

 

 

 

 

 

 

 

SET+HOLD>OFF

Menu switch No. Set value No.

Menu switch setting

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

002:OPERATION LOCK

 

 

 

 

 

 

 

 

 

OFF

 

M

 

 

 

 

 

 

003:SYNC SELECT

H

S

F

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

005:AUTO TRACKING

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

008:CAP LOCK(525)

 

 

 

 

 

 

 

 

 

SW SEL

 

 

 

 

 

 

 

 

 

009:CAP RE-LOCKING DIR.

 

 

 

 

 

 

 

 

 

ACCELERATION

 

 

 

 

 

 

 

 

 

300:DIRECT EJECT

 

 

 

 

 

 

 

 

 

ON

H

M

S

F

301:DIRECT SEARCH

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

302:BACK SPACE

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

307:PAUSE/STILL/STP TIME

 

 

 

 

 

 

 

 

 

5MIN

 

 

 

 

 

 

 

 

 

311:AUTO PLAY

 

 

 

 

 

 

 

 

 

OFF

Operation procedure

1.Call up the menu switch setting display. Press the [MENU] button to call up the menu screen on the counter display and on-screen display. When the top menu is displayed, turn the jog dial to show the menu switch setting screen.

On-screen display data are output through the rear panel [LINE2-SUPER] connector.

The counter display shows menu switch number.

2.Select a menu switch item to set by turning the jog dial.

The selected menu switch number blinks on the on-screen display.

The menu switch number changes on the counter display.

3.Select the setting value of the menu switch by turning the jog dial while pressing the [SEARCH] button.

Repeat steps 2 and 3 to change other items.

4.Press the [SET] button to enter the finalized settings in memory.

During setting, “SET” blinks on the counter display and “MENU SET” blinks on the on- screen display. When setting is complete, the normal screen is restored.

¥When a cassette tape recorded on a signal system other than that set for this unit is played back, the corresponding indicator ([525] or [625]) blinks.

When the NTSC system is selected and a PAL tape is played back, the [625] indicator blinks. When the PAL system is selected and an NTSC tape is played back, the [525] indicator blinks.

¥If required, select the audio reference level (-20 dB/-18 dB) for recording with menu switch No. 257 <AUD.

REF. SIGNAL LEV. >. (See page 54.)

 

 

 

 

 

 

 

 

 

300:DIRECT EJECT

 

 

 

 

 

 

 

 

 

OFF

H

M

 

S

 

 

301:DIRECT SEARCH

 

 

F

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

302:BACK SPACE

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

307:PAUSE/STILL/STP TIME

 

 

 

 

 

 

 

 

 

5MIN

 

 

 

 

 

 

 

 

 

311:AUTO PLAY

 

 

 

 

 

 

 

 

 

OFF

30

31

Image 16
Contents BR-D95U This instruction book is made from 100% recycled paperImportant Safeguards This unit should be used with 120 V AC onlyPort Cable Length Main Features ContentsMaintenance IntroductionOutline Other FunctionsHead Cleaning PrecautionsVideo Cassette Front Panel Video Input indicators Audio signal select buttonsSetting buttons  Menu button $PB PB/EE button PAUSE/STILL SUB Panel Rear PanelCounter Display ON-SCREEN Display Operation mode display in the Variable MUTING/CONDITION Alarm displayConnections Input ConnectionsEditing remote control connection Output ConnectionsControl System Connections Composite OUTMenu Switch Setting 00A Menu SettingMenu Display Modes 00F Fixed Time EntryVideo Signal System Selection PALSaving and Calling UP Menu Switch Settings Enabling the Direct Access functionAccess ÒonóChanging the registered menu switch setting Erasing all registered items on the User Activating the menu switch lock functionErasing registered items one at a time Recording Current Adjustment Activating the recording current adjustment functionMenu Switch List Menu Switch Setting DetailsFunctions enclosed Are not available on the PAL system Menu Switch Setting Content ECC Mode VD REC SignalNormal Slow Picture FrameLine Setup WideExtra Line PB MutingVblank Ycomb OFF on OFF WITH21 VblankFactory setting AT 2CH CH1 0DBCH2 CH3PB/EE Mode SettingSilence PAUSE/STILL SEC STP/TIMEDiag AT OFF Power on 0SEC15SEC StillSwap Mode Disable SafetyTime Code PARA-RUN OFFSynchro Disable Nization Enable Regen ModeCF Flag Reply FLDUB Preset OFF Auto Mode ASM INS 0FFRemain Enable EXT LTC Regen TC VitcOperation Mode Lock PreparationLoading the cassette Turn the Power switch on Remove the cassette from the slot PrecautionsStandby ON/OFF Load the cassetteRecording Input Video and Audio Signal SelectionPreparation for Recording Audio Monitor Output Signal Selection Audio Record Level AdjustmentBasic Recording Operations Playback Digital Audio Signal INPUT/OUTPUTPreparation for Playback Audio Playback Level Adjustment Audio Playback Level Lock modeManual audio playback level adjustment Basic Playback OperationsPlay volume control Set menu switch No Auto Tracking to OFFAdjust until the tracking meter level reaches the maximum Manual Tracking AjustmentSimplified Playback Speed Adjustment Function Error CorrectionAudio V. Fade Function Shuttle SEARCH/JOG Operation Variable Slow PlaybackTo stop search operation Jog operation Turn the inner jog dialProgram Playback User Setting Other Functions11 FF, REW and Counter Memory Functions Extra Line Data RECORDING/PLAYBACKSignals. Factory setting Auto When video signals are output, extra lineExtra line data playback Line recordingSimultaneous Operation Fixed Time CUE UP FunctionEngage the Multi Cue-Up mode Quit the Multi Cue modeMulti CUE-UP Function Cue Operation buttons DisplayStriping REC Menu Striping RECHOW to USE Time Code Time Code Initial Setting PresetFront sub panel switches for time code setting Time Code DisplayTime Code Recording Time Code Playback Front sub panel switch settingRecord the time code Time Code Switch Setting for Editing SUB Time Code Recording and PlaybackEditing Assemble editing Insert editingRecording PlaybackEditing procedure Color Frame Servo SettingPreparation Swap Editing Editing mode selectionEdit point entry Preview editing Editing actualReview check Correcting the edit pointAudio Split Editing Other FunctionEditing with the PRE-READ Function Manual EditingEditing System Phase Adjustment Example of editing system configurationThat allows you to bypass the frame memory Refer toSelect the adjustment item by turning the jog dial Adjustment items on screen can be selected with the cursorRepeat steps 2 to 3 to adjust other items Item belowAdjustment Dubbing Loop Function 122Basic Table JVC-1 Table0A ACK 0B NAKFlag Reset Out Flag Reset3F Stop Key CueUp With DataB6 Rev Shuttle Key C0 Auto Edit KeyExecutes Auto Edit on the VCR C1 Preview Key Basic TableE4 Out Data Preset E6 Preroll TimePreset Basic TableE7 Timer Mode Select E5 Edit PresetF6 JVC On F7 Basic Table OnFA Rec/DubRequest FB VTR INDSpeed/data correspondence table For the current timer mode Timer modeCurrent timer mode Bit-3 Auto modeDATA0 0A DATA0 0BDATA0 1B DATA0 0EDATA0 0F DATA0 1FDATA0 1D On-screen display TroubleshootingCode Troubles not to be Warned by Indicators Symptoms Cause Not operable Remote button is set to RemoteOn-screen display Behavior and actions to be taken ActionOptional Accessories AppendixUnit mm Specifications150